Javascript must be enabled to continue!
ICP-OES Analysis of Siddha Formulation Venkara Mathirai
View through CrossRef
Background: The Venkara Mathirai(VM) is a herbomineral formulation used for treating ulcer, anaemia and Arthritis. Objective: The objective of the present study is to detect heavy metals (arsenic, lead, cadmium, mercury) and other elements within the permissible limits as per WHO guidelines present in the Siddha herbo-mineral Formulation “Venkara Mathirai”. Materials and
Methods: The ingredients were collected and purified and the drug was prepared as per Siddha literature “Siddha Vaithiya Thirattu”. Here, the drug was subjected to standardization by simultaneous ICP-OES analysis equipment (PERKIN ELMER OPTIMA 5300 DV).
Result: This paper revealed the therapeutic safer level of heavy metals and other elements present in Venkara Mathirai, as per WHO guidelines with the help of simultaneous ICP- OES analysis equipment (PERKIN ELMER OPTIMA 5300 DV).
Conclusion: From the ICP-OES analysis reveals that Venkara Mathirai are free from heavy metals there by proving the safety of its utilization in siddha system. This study forms the base for the pharmaceutical analysis of Venkara Mathirai (VM) which will be followed by safe and efficacy studies later.
Keywords: Venkara Mathirai, Siddha medicine, ICP-OES, Ulcer.
Galore Knowledge Publication Pvt. Ltd.
Title: ICP-OES Analysis of Siddha Formulation Venkara Mathirai
Description:
Background: The Venkara Mathirai(VM) is a herbomineral formulation used for treating ulcer, anaemia and Arthritis.
Objective: The objective of the present study is to detect heavy metals (arsenic, lead, cadmium, mercury) and other elements within the permissible limits as per WHO guidelines present in the Siddha herbo-mineral Formulation “Venkara Mathirai”.
Materials and
Methods: The ingredients were collected and purified and the drug was prepared as per Siddha literature “Siddha Vaithiya Thirattu”.
Here, the drug was subjected to standardization by simultaneous ICP-OES analysis equipment (PERKIN ELMER OPTIMA 5300 DV).
Result: This paper revealed the therapeutic safer level of heavy metals and other elements present in Venkara Mathirai, as per WHO guidelines with the help of simultaneous ICP- OES analysis equipment (PERKIN ELMER OPTIMA 5300 DV).
Conclusion: From the ICP-OES analysis reveals that Venkara Mathirai are free from heavy metals there by proving the safety of its utilization in siddha system.
This study forms the base for the pharmaceutical analysis of Venkara Mathirai (VM) which will be followed by safe and efficacy studies later.
Keywords: Venkara Mathirai, Siddha medicine, ICP-OES, Ulcer.
Related Results
Beyond Vienna: MS/MS Option for the Neoma MC-ICP-MS.
Beyond Vienna: MS/MS Option for the Neoma MC-ICP-MS.
<p>The introduction and rapid adoption of triple quadrupole ICP-MS/MS in the last decade<sup>1</sup> has seen the development of many exci...
Physicochemical characterization, Phytochemical analysis and Anti-microbial activity of Elathy mathirai
Physicochemical characterization, Phytochemical analysis and Anti-microbial activity of Elathy mathirai
Elathy Mathirai is a Siddha herbomineral formulation indicated to cure sori(itching), sirangu(Scabies), suram(fever), vaayu, maandham(gastro intestinal disorder) . The aim of the s...
CONTROLE DE BOTRYTIS CINEREA NA PÓS-COLHEITA DO MORANGUEIRO (FRAGARIA SP.) COM DIFERENTES ÓLEOS ESSENCIAIS
CONTROLE DE BOTRYTIS CINEREA NA PÓS-COLHEITA DO MORANGUEIRO (FRAGARIA SP.) COM DIFERENTES ÓLEOS ESSENCIAIS
O morango (Fragaria × ananassa) é uma cultura cultivada em todo o mundo, alcançando cerca de 372.000 hectares (ha), sendo no Brasil utilizado 390ha para cultivo com rendimento de 8...
The utility of MRI radiological biomarkers in determining intracranial pressure
The utility of MRI radiological biomarkers in determining intracranial pressure
Abstract
Background
Intracranial pressure (ICP) is a physiological parameter that conventionally requires invasive monitoring f...
Comparative Investigation of Different Telemetric Methods for Measuring Intracranial Pressure: A Prospective Pilot Study
Comparative Investigation of Different Telemetric Methods for Measuring Intracranial Pressure: A Prospective Pilot Study
Abstract
Objectives: Measurement of intracranial pressure (ICP) plays an important role in long-term monitoring and neuro-intensive treatment of patients with a cerebral sh...
Determination of As, Hg, Pb and Zr in Pyrotechnic Compositions by ICP-OES
Determination of As, Hg, Pb and Zr in Pyrotechnic Compositions by ICP-OES
Fireworks produce spectacular visual effects through the combustion and explosion of pyrotechnic compositions, which are made up of oxidizers, fuels, colorants and binders. To impr...
Positive end-expiratory pressure increases intracranial pressure but not pressure reactivity index in supine and prone positions: a porcine model study
Positive end-expiratory pressure increases intracranial pressure but not pressure reactivity index in supine and prone positions: a porcine model study
IntroductionPositive end-expiratory pressure (PEEP) and prone positioning can improve gas exchange by promoting uniform lung aeration. However, elevated ventilation pressures may i...
Extracranial pressure (ECP) monitoring in severe traumatic brain injury (TBI): A prospective study validating intra-abdominal pressure (IAP) measurement for predicting intracranial pressure (ICP)
Extracranial pressure (ECP) monitoring in severe traumatic brain injury (TBI): A prospective study validating intra-abdominal pressure (IAP) measurement for predicting intracranial pressure (ICP)
Background:
Intracranial pressure (ICP)--guided therapy is the standard of care in the management of severe traumatic brain injury (TBI). Ideal ICP monitoring technique is not yet...