Javascript must be enabled to continue!
Stage-Discharge Relationships of Drawdown Plates for Denitrifying Woodchip Bioreactors
View through CrossRef
Highlights
Drawdown plates can prevent prolonged saturation in denitrifying woodchip bioreactors.
Contraction coefficients for the orifice equation ranged from 0.74 to 0.76.
Drawdown orifice should be sized appropriately to avoid interfering with design flow rates.
Established stage-discharge relationships for drawdown orifice improve accuracy of flow monitoring.
Abstract.Denitrifying woodchip bioreactors are a conservation drainage practice used to reduce nitrate loads in tile drainage water from field crops. Prolonged saturation in the woodchip media under no flow or low flow conditions can result in the production of hydrogen sulfide and methane. The US Department of Agriculture Natural Resources Conservation Service’s (NRCS) Conservation Practice Standard for denitrifying bioreactors recommends a low-level orifice at the bioreactor outlet to drain the woodchip media within 48 h to prevent prolonged stagnation. This study determined stage-discharge relationships for three drawdown configurations in an AgriDrain water level control structure (15.2 cm nominal tile size) to improve accuracy of estimating flow in field bioreactors. Tested drawdown configurations consisted of a custom-made inverted-v orifice plate currently used by the NRCS (3.6 cm
2
orifice area); and a 2 and an 8 mm gap between the base of the structure and the bottom stop log (2.6 and 12.3 cm
2
orifice area, respectively). The stage-discharge relationship for all three orifices was accurately described by the orifice flow equation (R
2
> 0.99). Stage-discharge relationship for the inverted-v drawdown plate in combination with a stainless steel-edged v-notch weir was the sum of their respective stage-discharge relationships for orifice flow and flow over the weir. Contraction coefficients for the inverted-v, 2 mm gap, and 8 mm gap configurations were 0.74, 0.74, and 0.76, respectively. The stage-discharge relationships for the inverted-v, 2 mm gap, and 8 mm gap configurations were Q = 3.26*A*h
0.5
, Q = 3.29*A*h
0.5
, and Q = 3.38*A*h
0.5
, respectively, where Q is in m
3
s
-1
, A is the orifice area in m
2
, and h is the water head differential in meters. Keywords: Denitrifying bioreactor, Drawdown plate, Flow monitoring, NRCS, Prolonged saturation.
American Society of Agricultural and Biological Engineers (ASABE)
Title: Stage-Discharge Relationships of Drawdown Plates for Denitrifying Woodchip Bioreactors
Description:
Highlights
Drawdown plates can prevent prolonged saturation in denitrifying woodchip bioreactors.
Contraction coefficients for the orifice equation ranged from 0.
74 to 0.
76.
Drawdown orifice should be sized appropriately to avoid interfering with design flow rates.
Established stage-discharge relationships for drawdown orifice improve accuracy of flow monitoring.
Abstract.
Denitrifying woodchip bioreactors are a conservation drainage practice used to reduce nitrate loads in tile drainage water from field crops.
Prolonged saturation in the woodchip media under no flow or low flow conditions can result in the production of hydrogen sulfide and methane.
The US Department of Agriculture Natural Resources Conservation Service’s (NRCS) Conservation Practice Standard for denitrifying bioreactors recommends a low-level orifice at the bioreactor outlet to drain the woodchip media within 48 h to prevent prolonged stagnation.
This study determined stage-discharge relationships for three drawdown configurations in an AgriDrain water level control structure (15.
2 cm nominal tile size) to improve accuracy of estimating flow in field bioreactors.
Tested drawdown configurations consisted of a custom-made inverted-v orifice plate currently used by the NRCS (3.
6 cm
2
orifice area); and a 2 and an 8 mm gap between the base of the structure and the bottom stop log (2.
6 and 12.
3 cm
2
orifice area, respectively).
The stage-discharge relationship for all three orifices was accurately described by the orifice flow equation (R
2
> 0.
99).
Stage-discharge relationship for the inverted-v drawdown plate in combination with a stainless steel-edged v-notch weir was the sum of their respective stage-discharge relationships for orifice flow and flow over the weir.
Contraction coefficients for the inverted-v, 2 mm gap, and 8 mm gap configurations were 0.
74, 0.
74, and 0.
76, respectively.
The stage-discharge relationships for the inverted-v, 2 mm gap, and 8 mm gap configurations were Q = 3.
26*A*h
0.
5
, Q = 3.
29*A*h
0.
5
, and Q = 3.
38*A*h
0.
5
, respectively, where Q is in m
3
s
-1
, A is the orifice area in m
2
, and h is the water head differential in meters.
Keywords: Denitrifying bioreactor, Drawdown plate, Flow monitoring, NRCS, Prolonged saturation.
Related Results
Field scale optimization of woodchip bioreactors for nitrate removal from drainage water in the Netherlands
Field scale optimization of woodchip bioreactors for nitrate removal from drainage water in the Netherlands
It is known from recent international research that woodchip bioreactors can be an effective measure to reduce emissions of nitrate from agricultural drainage water. In the Netherl...
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Biosurfactants are natural substances produced by several bacterial and fungal organisms that are amphiphilic and are extracellular (a part of the cell membrane). Biosurfactants ca...
Atypical Presentations of Pilonidal Sinus Disease: A Case Series with Literature Review
Atypical Presentations of Pilonidal Sinus Disease: A Case Series with Literature Review
Abstract
Introduction: Pilonidal sinus (PNS) typically arises in the sacrococcygeal region but can occasionally present in atypical locations, including the axilla, intermammary re...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Optimizing Drawdown Strategies in Wells Producing from Complex Fracture Networks
Optimizing Drawdown Strategies in Wells Producing from Complex Fracture Networks
Abstract
In unconventional reservoirs, the presence of natural fractures coupled with high pore pressures leads to the creation of complex fracture networks. Duri...
Slope Stability Analysis of Main Irrigation Canals Due to Rapid Drawdown Fluctuations Using Numerical Modeling
Slope Stability Analysis of Main Irrigation Canals Due to Rapid Drawdown Fluctuations Using Numerical Modeling
Rapid drawdown conditions frequently threaten the stability of irrigation canal embankments, especially in cohesive alluvial soils with low hydraulic conductivity. This study inves...
Rotating characteristics of glow discharge filament on liquid electrode surface
Rotating characteristics of glow discharge filament on liquid electrode surface
Atmospheric pressure glow discharge above liquid electrode has extensive application potentials in biomedicine, chemical degradation,environmental protection,etc.In this paper,such...
High-Frequency Bromide Sensor Performance during Denitrifying Bioreactor Tracer Testing
High-Frequency Bromide Sensor Performance during Denitrifying Bioreactor Tracer Testing
Abstract.
High-frequency bromide (Br-) sensors could resolve challenges during denitrifying bioreactor tracer tests.
Depl...

