A new tube chamber system for evaluation of anterior chamber pressure during phacoemulsification tested in porcine eyes

View through CrossRef
AIM: To measure the optimal anterior chamber pressure (ACP) for safe phacoemulsification using a new tube chamber system with internal pressure measurement function in the porcine eye. METHODS: The 20-gauge and 21-gauge straight tips with yellow and orange sleeves, respectively, were covered by a test chamber combined with a pressure sensor for measuring ACP. This was measured for 20s from 10s after starting aspiration in the linear mode using vacuum levels of 200 and 150 mm Hg with a 20-gauge tip, and 300 and 250 mm Hg with a 21-gauge tip. Using a porcine eye, a pressure sensor fixed with a 0.9 mm corneal incision measured ACP. For the posterior capsule contact assay, porcine eyes were treated as described above, and the ultrasonic needle tip was held at the height of the iris and aspirated for 30s in linear mode at a vacuum of 200 and 150 mm Hg for the 20-gauge tip, and 300 and 250 mm Hg for the 21-gauge tip. The bottle height at which the posterior capsule accidentally contacted the ultrasonic tip was recorded, and the estimated ACP was calculated. RESULTS: The internal pressure of the new tube chamber system and ACP from the porcine eye closely matched proportional changes at vacuum levels of 200 and 150 mm Hg with 20-gauge tips. Similarly, proportional changes at vacuum levels of 300 and 250 mm Hg with the 21-gauge tip were nearly equal. The bottle height at which the posterior capsule contacted with the tip and estimated ACP were 57.5±12.6 cm (20.2±7.9 mm Hg) at 200 mm Hg with a 20-gauge tip, 35.0±10.0 cm (16.6±6.3 mm Hg) at 150 mm Hg with a 20-gauge tip, 47.5±12.6 cm (18.7±8.7 mm Hg) at 300 mm Hg with a 21-gauge tip, and 32.5±5.0 cm (15.7±3.5 mm Hg) at 250 mm Hg with a 21-gauge tip. CONCLUSION: A comprehensive understanding of this chamber system’s characteristics and usage can resolve anterior chamber instability caused by changing preoperative settings on the phaco machine.
Title: A new tube chamber system for evaluation of anterior chamber pressure during phacoemulsification tested in porcine eyes
Description:
AIM: To measure the optimal anterior chamber pressure (ACP) for safe phacoemulsification using a new tube chamber system with internal pressure measurement function in the porcine eye.
METHODS: The 20-gauge and 21-gauge straight tips with yellow and orange sleeves, respectively, were covered by a test chamber combined with a pressure sensor for measuring ACP.
This was measured for 20s from 10s after starting aspiration in the linear mode using vacuum levels of 200 and 150 mm Hg with a 20-gauge tip, and 300 and 250 mm Hg with a 21-gauge tip.
Using a porcine eye, a pressure sensor fixed with a 0.
9 mm corneal incision measured ACP.
For the posterior capsule contact assay, porcine eyes were treated as described above, and the ultrasonic needle tip was held at the height of the iris and aspirated for 30s in linear mode at a vacuum of 200 and 150 mm Hg for the 20-gauge tip, and 300 and 250 mm Hg for the 21-gauge tip.
The bottle height at which the posterior capsule accidentally contacted the ultrasonic tip was recorded, and the estimated ACP was calculated.
RESULTS: The internal pressure of the new tube chamber system and ACP from the porcine eye closely matched proportional changes at vacuum levels of 200 and 150 mm Hg with 20-gauge tips.
Similarly, proportional changes at vacuum levels of 300 and 250 mm Hg with the 21-gauge tip were nearly equal.
The bottle height at which the posterior capsule contacted with the tip and estimated ACP were 57.
5±12.
6 cm (20.
2±7.
9 mm Hg) at 200 mm Hg with a 20-gauge tip, 35.
0±10.
0 cm (16.
6±6.
3 mm Hg) at 150 mm Hg with a 20-gauge tip, 47.
5±12.
6 cm (18.
7±8.
7 mm Hg) at 300 mm Hg with a 21-gauge tip, and 32.
5±5.
0 cm (15.
7±3.
5 mm Hg) at 250 mm Hg with a 21-gauge tip.
CONCLUSION: A comprehensive understanding of this chamber system’s characteristics and usage can resolve anterior chamber instability caused by changing preoperative settings on the phaco machine.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Tube Shunt Related Complications of the Anterior Chamber
Tube Shunt Related Complications of the Anterior Chamber
Postoperative complications in the anterior chamber can affect both glaucoma progression and vision. Preoperative considerations and surgical technique are important to reduce and ...
Tube Shunt Related Complications in Pediatrics
Tube Shunt Related Complications in Pediatrics
Although medical therapy is usually an excellent therapeutic option in the adult population, in children it is often ineffective or associated with an undesirable risk:benefit rati...
Stability of anterior segments in patients with moderate and high myopia one year after SMILE
Stability of anterior segments in patients with moderate and high myopia one year after SMILE
Abstract Background: SMILE is one of the most leading-edge corneal refractive surgery.In our study, we aim to investigate the stability of anterior segments in patients wit...
Tube Shunt Related Complications of the Cornea
Tube Shunt Related Complications of the Cornea
Tube shunts can be placed in the anterior chamber, the ciliary sulcus, or the pars plana. However, if the eye is phakic, the choice is limited to the anterior chamber; ciliary sulc...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
Effect of Die Velocity on Tube Deformation Mechanics During Low Pressure Tube Hydroforming Process Sequence Variation
Effect of Die Velocity on Tube Deformation Mechanics During Low Pressure Tube Hydroforming Process Sequence Variation
Abstract Tube hydroforming is one of the successful manufacturing processes to create a variety of shapes using fluid pressure. The process fills the tube with fluid...

Back to Top