Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation of electrically isolated capacitive sensing skins on concrete to reduce structure/sensor capacitive coupling

View through CrossRef
Abstract Damage to bridges can result in partial or complete structural failures, with fatal consequences. Cracks develop in concrete infrastructure from fatigue loading, vibrations, corrosion, or unforeseen structural displacement. Effective long-term monitoring of civil infrastructure can reduce the risk of structural failures and potentially reduce the cost and frequency of inspections. However, deploying structural health monitoring technologies for crack detection on bridges is expensive, especially long-term, due to the density of sensors required to detect, localize, and quantify cracks. Previous research on soft elastomeric capacitors (SECs) has shown their viability for low-cost monitoring of cracks in transportation infrastructure. However, when deployed on concrete for strain monitoring, a structure/sensor capacitive coupling exists that may cause a significant amplification in the signal collected from the SEC sensor. This work provides a detailed experimental study of electrically isolating capacitive sensing skins for concrete structures to reduce the structure/sensor capacitive coupling of an electrically grounded sensor. The study illustrates that the use of rubber isolators effectively decreases the capacitive coupling between concrete, which inherently has capacitive properties, and sensors such as the SEC that utilize capacitance measurements. In addition, the required thickness of isolation for accurate strain monitoring using the SEC with geometry described in the paper is investigated and better strain correlation is observed between the rubber of isolation thickness 0.30 mm and 0.64 mm with rubber of isolation of approximately 0.40 mm having the best response. Tests were conducted on small-scale concrete beams, and results were validated on full-scale reinforced concrete bridge decks recently taken out of service. This study demonstrates that with proper isolation material, the SEC can accurately transduce strain from concrete within a 10 μ ε error for strain levels beyond 25 μ ε .
Title: Investigation of electrically isolated capacitive sensing skins on concrete to reduce structure/sensor capacitive coupling
Description:
Abstract Damage to bridges can result in partial or complete structural failures, with fatal consequences.
Cracks develop in concrete infrastructure from fatigue loading, vibrations, corrosion, or unforeseen structural displacement.
Effective long-term monitoring of civil infrastructure can reduce the risk of structural failures and potentially reduce the cost and frequency of inspections.
However, deploying structural health monitoring technologies for crack detection on bridges is expensive, especially long-term, due to the density of sensors required to detect, localize, and quantify cracks.
Previous research on soft elastomeric capacitors (SECs) has shown their viability for low-cost monitoring of cracks in transportation infrastructure.
However, when deployed on concrete for strain monitoring, a structure/sensor capacitive coupling exists that may cause a significant amplification in the signal collected from the SEC sensor.
This work provides a detailed experimental study of electrically isolating capacitive sensing skins for concrete structures to reduce the structure/sensor capacitive coupling of an electrically grounded sensor.
The study illustrates that the use of rubber isolators effectively decreases the capacitive coupling between concrete, which inherently has capacitive properties, and sensors such as the SEC that utilize capacitance measurements.
In addition, the required thickness of isolation for accurate strain monitoring using the SEC with geometry described in the paper is investigated and better strain correlation is observed between the rubber of isolation thickness 0.
30 mm and 0.
64 mm with rubber of isolation of approximately 0.
40 mm having the best response.
Tests were conducted on small-scale concrete beams, and results were validated on full-scale reinforced concrete bridge decks recently taken out of service.
This study demonstrates that with proper isolation material, the SEC can accurately transduce strain from concrete within a 10 μ ε error for strain levels beyond 25 μ ε .

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Study on the effect of seawater on making and curing of unreinforced concrete applications
Study on the effect of seawater on making and curing of unreinforced concrete applications
Concrete, an essential component of worldwide infrastructure, depends significantly on fresh water for its manufacturing, contributing to freshwater scarcity in many regions. As co...
Lubricating Effects Against Interfaces Shear Strength Of Soil–Concrete And Concrete–Concrete
Lubricating Effects Against Interfaces Shear Strength Of Soil–Concrete And Concrete–Concrete
Box Jacking is a trenchless method of underpass construction that consists in pushing one or more prefabricated concrete boxes into the soil using high capacity hydraulic jacks, wh...
Evaluations of concrete mix stability for below-grade applications
Evaluations of concrete mix stability for below-grade applications
Drilled shafts are a commonly utilized foundation type for bridge construction, especially for bridges involving large loads or difficult ground conditions. Proper construction is ...
Development of textile capacitive sensor
Development of textile capacitive sensor
(English) Nowadays, the textile clothing industry is searching for new ways to add value to their products. Developments in textile sensors start to demonstrate their usability an...
Energy efficient cooperative node management for wireless multimedia sensor networks
Energy efficient cooperative node management for wireless multimedia sensor networks
In Wireless Multimedia Sensor Networks (WMSNs) the lifetime of battery operated visual nodes is limited by their energy consumption, which is proportional to the energy required fo...
The interaction between neural populations: Additive versus diffusive coupling
The interaction between neural populations: Additive versus diffusive coupling
Abstract Models of networks of populations of neurons commonly assume that the interactions between neural populations are via ...

Back to Top