Javascript must be enabled to continue!
Optimiser™: The next generation of microplates (144.18)
View through CrossRef
Abstract
The Optimiser™ microplates combine the power of microfluidics with the 96-well architecture to offer unparalleled performance. The Optimiser consists of an array of wells defined on one face of a substrate connected to microfluidic channels on the opposing face. The channels are sealed by a sealing layer with opening at outlet of the channel, which in turn connects to an absorbent pad. In the Optimiser the microfluidic channel (with a 50% higher surface area and 50x higher surface area to volume ratio) serves as the reaction chamber, allowing for low volume, rapid assay reactions. During use, the first reagent is added to the well, drawn into the channel by capillary forces and transported to the absorbent pad and partially sucked out. The unique design allows the liquid to exit the well but be trapped within the channel for static incubation. Further steps only involve sequential reagent additions which are transported through the channel for a complete assay sequence. The Optimiser has been successfully tested in chemifluorescence mode to demonstrate comparable sensitivity to a 96-well plate with < 1/3rd sample volume. Alternately with similar sample volumes, the Optimiser boasts >10x higher sensitivity, to achieve detection limits of < 1 pg from a 100 µl sample. In all cases, a complete sandwich assay can be completed in < 30 minutes with the Optimiser. The Optimiser conforms to ANSI microplate specs and can be used with all current microplate instruments.
Oxford University Press (OUP)
Title: Optimiser™: The next generation of microplates (144.18)
Description:
Abstract
The Optimiser™ microplates combine the power of microfluidics with the 96-well architecture to offer unparalleled performance.
The Optimiser consists of an array of wells defined on one face of a substrate connected to microfluidic channels on the opposing face.
The channels are sealed by a sealing layer with opening at outlet of the channel, which in turn connects to an absorbent pad.
In the Optimiser the microfluidic channel (with a 50% higher surface area and 50x higher surface area to volume ratio) serves as the reaction chamber, allowing for low volume, rapid assay reactions.
During use, the first reagent is added to the well, drawn into the channel by capillary forces and transported to the absorbent pad and partially sucked out.
The unique design allows the liquid to exit the well but be trapped within the channel for static incubation.
Further steps only involve sequential reagent additions which are transported through the channel for a complete assay sequence.
The Optimiser has been successfully tested in chemifluorescence mode to demonstrate comparable sensitivity to a 96-well plate with < 1/3rd sample volume.
Alternately with similar sample volumes, the Optimiser boasts >10x higher sensitivity, to achieve detection limits of < 1 pg from a 100 µl sample.
In all cases, a complete sandwich assay can be completed in < 30 minutes with the Optimiser.
The Optimiser conforms to ANSI microplate specs and can be used with all current microplate instruments.
Related Results
miRNA-144/451 Regulates Cell Surface TfR1 Expression in Normal and β-Thalassemic Erythroblasts
miRNA-144/451 Regulates Cell Surface TfR1 Expression in Normal and β-Thalassemic Erythroblasts
β-thalassemia is a common inherited blood disorder caused by mutations in the β-globin gene (HBB) leading to a reduction of the corresponding protein. Consequently, excess free α-g...
Wellmap: a file format for microplate layouts
Wellmap: a file format for microplate layouts
Abstract
Objective
Microplates are ubiquitous in biological research because they make it easy to collect data for hundreds of different conditions ...
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
The article examines the load change schedule of the solar power plant in the Ukraine-Moldova energy union. The analysis of data averaged at minute and 15-minute intervals in the p...
Spirometric surveillance of obstructive lung diseases
Spirometric surveillance of obstructive lung diseases
Background: Obstructive Lung Disease (OLD) becomes global health issues that influencing the physical health and economic conditions of people. Chronic Respiratory Disease (CRD) is...
Resource provisioning and dynamic optimization of Network Slices in an SDN/NFV environment
Resource provisioning and dynamic optimization of Network Slices in an SDN/NFV environment
Provisionnement des ressources et optimisation dynamique des slices réseaux dans un environnement SDN/NFV
Pour offrir le haut débit mobile amélioré, les communicati...
Downhole Power Generation: Status, Problems, and Prospects
Downhole Power Generation: Status, Problems, and Prospects
Abstract
Downhole power generation is an important technology for the oil/gas industry. It provides a steady source of power for all types of operations, including d...
Three Steps to Improve Jellyfish Search Optimiser
Three Steps to Improve Jellyfish Search Optimiser
This paper describes three different mechanisms used in Jellyfish Search (JS) optimiser. At first, an archive of good old solutions is used to prevent getting stuck in the local-op...
Autonomous or assisted deployment by mobile robots of wireless sensor networks : coverage and connectivity issues
Autonomous or assisted deployment by mobile robots of wireless sensor networks : coverage and connectivity issues
Déploiement autonome ou assisté par des robots mobiles d'un réseau de capteurs sans fil : couverture et connectivité
Les réseaux de capteurs sans fil sont déployés ...

