In vivo thermographic analysis of clear corneal incision during phacoemulsification: comparison for coaxial, microcoaxial and bimanual techniques
View through CrossRef
Abstract Purpose To measure the wound corneal temperature of clear corneal incisions (CCIs) during phacoemulsification (PKE) using different surgical techniques: standard coaxial, microincision coaxial and microincision bimanual. Methods Human corneal emissivity was determined on corneal graft with the “Black Tape” method. After validation of the method on porcine corneas, the temperature of 35 CCIs was recorded continuously during PKE (7 coaxial with 1.8 mm incision, 14 coaxial 2.2 mm, 8 coaxial 2.75 mm, and 6 bimanual 1.3 mm) using portable laser targeted infrared thermometer. Results No thermal differences were observed within the three groups in PKE mode 1 (nucleus sculpting and grooving) (p=0.56) and in PKE mode 2 (nuclear fragments phacoemulsification) (p=0.32). Bimanual 1.3 mm CCIs’s temperature was lower than the three other groups during irrigation‐aspiration mode (p<0.05). Conclusion Clear corneal microincisions did not induce temperature increase of CCIs during phacoemulsification compared to larger incisions.
Title: In vivo thermographic analysis of clear corneal incision during phacoemulsification: comparison for coaxial, microcoaxial and bimanual techniques
Description:
Abstract Purpose To measure the wound corneal temperature of clear corneal incisions (CCIs) during phacoemulsification (PKE) using different surgical techniques: standard coaxial, microincision coaxial and microincision bimanual.
Methods Human corneal emissivity was determined on corneal graft with the “Black Tape” method.
After validation of the method on porcine corneas, the temperature of 35 CCIs was recorded continuously during PKE (7 coaxial with 1.
8 mm incision, 14 coaxial 2.
2 mm, 8 coaxial 2.
75 mm, and 6 bimanual 1.
3 mm) using portable laser targeted infrared thermometer.
Results No thermal differences were observed within the three groups in PKE mode 1 (nucleus sculpting and grooving) (p=0.
56) and in PKE mode 2 (nuclear fragments phacoemulsification) (p=0.
32).
Bimanual 1.
3 mm CCIs’s temperature was lower than the three other groups during irrigation‐aspiration mode (p<0.
05).
Conclusion Clear corneal microincisions did not induce temperature increase of CCIs during phacoemulsification compared to larger incisions.
Related Results
Functional and aesthetic comparison of lower lip split incisions and modification of McGregor incision. (Preprint)
Functional and aesthetic comparison of lower lip split incisions and modification of McGregor incision. (Preprint)
BACKGROUND
The open mouth provided the basis for various surgical approaches to tumours of the oral cavity(1). If this access is inadequate it is generally ...
Bikini Incision Modification of the Direct Anterior Approach
Bikini Incision Modification of the Direct Anterior Approach
Background:
Although the direct anterior approach (DAA) represents an intermuscular and internervous approach to total hip arthroplasty (THA), it did not reach global a...
COMPARISON OF POST-SURGICAL CORNEAL ASTIGMATISM WITH PHACOEMULSIFICATION AND SMALL INCISION CATARACT SURGERY
COMPARISON OF POST-SURGICAL CORNEAL ASTIGMATISM WITH PHACOEMULSIFICATION AND SMALL INCISION CATARACT SURGERY
Background: Cataract, characterized by opacification of the crystalline lens, remains a leading cause of reversible blindness worldwide. Surgical intervention is the only effective...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Comparison of Surgically Induced Astigmatism by Superior and Temporal Clear Corneal Incision in Phacoemulsification
Comparison of Surgically Induced Astigmatism by Superior and Temporal Clear Corneal Incision in Phacoemulsification
Cataract surgery has evolved into a refractive procedure where optimal visual outcomes depend not only on lens extraction but also on minimizing surgically induced astigmatism. Pre...
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
AIM: To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laser-assisted phacoemulsification (FLACS).
METHODS: This study enrolled patie...
Wound temperature profiles of coaxial mini‐incision versus sleeveless microincision phacoemulsification
Wound temperature profiles of coaxial mini‐incision versus sleeveless microincision phacoemulsification
AbstractBackgroundTemperature profiles at the corneal wound of coaxial mini‐incision (2.4 mm) cataract surgery and sleeveless microincision (1.1 mm) cataract surgery were compared....