Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Computation of variance in compartment model parameter estimates from dynamic PET data

View through CrossRef
Purpose:This paper investigates the validity of the analytical framework for variance (“analytical variance”) in kinetic parameter and macroparameter estimations. Analytical variance is compared against the variance obtained from Monte Carlo simulations (“MC variance”) for two different compartment models at different noise levels.Methods:Kinetic parameters for one‐tissue (1T) and two‐tissue (2T) compartment models are used to generate time–activity curves (TAC). Gaussian noise is added to the noiseless TAC to generate noise realizations for each noise level. The kinetic parameters are then estimated by minimizing the weighted squared error between the noisy TAC and the model output. Standard deviation is computed statistically from the estimated parameters and computed analytically using the framework at each noise level. The ratio of standard deviation to true parameter value obtained from Monte Carlo simulations and analytical computations is compared.Results:Difference between the analytical and MC variance increases with the level of noise and complexity of the compartment model. The standard deviation of the analytical variance also increases with the noise‐level and model complexity. The difference between the analytical and MC variance is less than 3% for 1T compartment model and less than 10% for 2T compartment model at all noise levels. In addition, the standard deviation in the analytical variance is less than 15% for 1T and 2T compartment models at all noise levels.Conclusions:These results indicate that the proposed framework for the variance in the kinetic parameter estimations can be used for 1T and 2T compartment models even in the existence of high noise.
Title: Computation of variance in compartment model parameter estimates from dynamic PET data
Description:
Purpose:This paper investigates the validity of the analytical framework for variance (“analytical variance”) in kinetic parameter and macroparameter estimations.
Analytical variance is compared against the variance obtained from Monte Carlo simulations (“MC variance”) for two different compartment models at different noise levels.
Methods:Kinetic parameters for one‐tissue (1T) and two‐tissue (2T) compartment models are used to generate time–activity curves (TAC).
Gaussian noise is added to the noiseless TAC to generate noise realizations for each noise level.
The kinetic parameters are then estimated by minimizing the weighted squared error between the noisy TAC and the model output.
Standard deviation is computed statistically from the estimated parameters and computed analytically using the framework at each noise level.
The ratio of standard deviation to true parameter value obtained from Monte Carlo simulations and analytical computations is compared.
Results:Difference between the analytical and MC variance increases with the level of noise and complexity of the compartment model.
The standard deviation of the analytical variance also increases with the noise‐level and model complexity.
The difference between the analytical and MC variance is less than 3% for 1T compartment model and less than 10% for 2T compartment model at all noise levels.
In addition, the standard deviation in the analytical variance is less than 15% for 1T and 2T compartment models at all noise levels.
Conclusions:These results indicate that the proposed framework for the variance in the kinetic parameter estimations can be used for 1T and 2T compartment models even in the existence of high noise.

Related Results

SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
A enfermagem é o pilar da assistência pois está na linha de frente do cuidado holístico, todavia esta é estigmatizada e desvalorizada, assim como não possui reconhecimento consider...
Comparative study of total-body PET and PET/MR in the diagnosis of liver metastases
Comparative study of total-body PET and PET/MR in the diagnosis of liver metastases
ObjectiveTo compare the diagnostic differences between total-body PET/CT (positron emission tomography/computed tomography) and PET/MR (positron emission tomography/magnetic resona...
Forced diuresis and dual-phase 18F-fluorodeoxyglucose-PET/CT scan for restaging of urinary bladder cancers
Forced diuresis and dual-phase 18F-fluorodeoxyglucose-PET/CT scan for restaging of urinary bladder cancers
Abstract Context: The results of 18 F-fluorodeoxyglucose (FDG)-PET imaging carried out with the current standard techniques for assessment of urinary tract cancers have...
Adaptive hybrid potential evapotranspiration (PET) prediction method based on automatic machine learning
Adaptive hybrid potential evapotranspiration (PET) prediction method based on automatic machine learning
Abstract In arid areas, estimation of crop water demand through potential evapotranspiration (PET) forecast has a guiding effect on water-saving irrigation, to cope with th...
Bridging bones
Bridging bones
Chapter 2 presents the evaluation of the feasibility of utilizing whole-body [18F]Fluoride PET/CT for visualizing molecular new bone formation in clinically active PsA patients. Th...
Pet Euthanasia and Human Euthanasia
Pet Euthanasia and Human Euthanasia
Photo ID 213552852 © Yuryz | Dreamstime.com Abstract A criticism of assisted death is that it’s contrary to the Hippocratic Oath. This opposition to assisted death assumes that dea...
Chromatin interaction analysis with updated ChIA-PET Tool (V3)
Chromatin interaction analysis with updated ChIA-PET Tool (V3)
AbstractUnderstanding chromatin interactions is important since they create chromosome conformation and link the cis- and trans-regulatory elements to their target genes for transc...

Back to Top