Background
Artificial intelligence (AI) strategies have been proposed for automatic landmark recognition applications with the expectation of simplifying and improving cephalometric analysis through accurate and consistent landmarks identification. The aim of the current study was to evaluate the accuracy and reliability of AI in identifying cephalometric landmarks for orthodontics cephalometric tracing.
Materials and methods
A total of 506 lateral cephalometric radiographs of patients aged 14–40 years were retrieved from the archives of Dubai Dental Hospital from the period of 2018–2021. Radiographs were traced using Dolphin imaging software, and the AI program (AI Ceph) was trained to identify 19 key cephalometric landmarks. Manual tracings were compared with AI-generated ones to evaluate the accuracy and reliability of the AI Ceph program.
Results
High agreement was observed between manual and AI-generated tracings. The highest concordance was detected for Menton (96.6%), whereas the lowest was observed for Nasion (86.6%). The deviation between the two methods was within 2 mm for all landmarks except Glabella (
p
< 0.02). Sensitivity values exceeded 80% for all evaluated landmarks except for Nasion and A-point where they showed a sensitivity of 72.7% and 78.8% respectively, demonstrating acceptable accuracy and reliability of the AI system.
Conclusions
The tested AI method was accurate and reliable for identifying cephalometric landmarks, with a clinically acceptable 2 mm deviation. AI-assisted cephalometric tracing may serve as a useful adjunctive tool to support orthodontists in diagnosis and treatment planning.
Title: Assessment of AI-based cephalometric landmark recognition on lateral cephalometric radiographs
Description:
Background
Artificial intelligence (AI) strategies have been proposed for automatic landmark recognition applications with the expectation of simplifying and improving cephalometric analysis through accurate and consistent landmarks identification.
The aim of the current study was to evaluate the accuracy and reliability of AI in identifying cephalometric landmarks for orthodontics cephalometric tracing.
Materials and methods
A total of 506 lateral cephalometric radiographs of patients aged 14–40 years were retrieved from the archives of Dubai Dental Hospital from the period of 2018–2021.
Radiographs were traced using Dolphin imaging software, and the AI program (AI Ceph) was trained to identify 19 key cephalometric landmarks.
Manual tracings were compared with AI-generated ones to evaluate the accuracy and reliability of the AI Ceph program.
Results
High agreement was observed between manual and AI-generated tracings.
The highest concordance was detected for Menton (96.
6%), whereas the lowest was observed for Nasion (86.
6%).
The deviation between the two methods was within 2 mm for all landmarks except Glabella (
p
< 0.
02).
Sensitivity values exceeded 80% for all evaluated landmarks except for Nasion and A-point where they showed a sensitivity of 72.
7% and 78.
8% respectively, demonstrating acceptable accuracy and reliability of the AI system.
Conclusions
The tested AI method was accurate and reliable for identifying cephalometric landmarks, with a clinically acceptable 2 mm deviation.
AI-assisted cephalometric tracing may serve as a useful adjunctive tool to support orthodontists in diagnosis and treatment planning.
Related Results
Assessment of the reliability of digital cephalometric analysis using One Ceph app in comparison with manual cephalometric analysis
Assessment of the reliability of digital cephalometric analysis using One Ceph app in comparison with manual cephalometric analysis
Objective: To evaluate and compare the accuracy and reliability of digital cephalometric tracing against the traditional manual tracing method.
Method: The retrospective, cross-sec...
Evaluation of endo-perio lesions according to different specific classifications
Evaluation of endo-perio lesions according to different specific classifications
Abstract
Introduction: Endo-perio lesions, beyond the clinical examination, are also assessed by means of radiographs. It is important that the radiographs used for diagnos...
Comparison of Semi and Fully Automated Artificial Intelligence Driven Softwares and Manual System for Cephalometric Analysis
Comparison of Semi and Fully Automated Artificial Intelligence Driven Softwares and Manual System for Cephalometric Analysis
Abstract
Background:
Cephalometric analysis has been used as one of the main diagnostic tools for orthodontic diagnosis and treatment planning. The analysis can be performe...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Multi-lateral Wells With Cemented Junctions
Multi-lateral Wells With Cemented Junctions
Abstract
Multi-lateral drilling and completion technology is advancing rapidly in the petroleum industry. It is currently being applied or considered for applicat...
Evaluation of Tweed’s Facial Triangle among Students in Lagos, Nigeria
Evaluation of Tweed’s Facial Triangle among Students in Lagos, Nigeria
Introduction: The advent of cephalometric analysis has aided orthodontic diagnostic procedures, while the Tweed’s facial triangle which is a type of cephalometric analysis has comp...
Comparison of angular measurements in cephalometrics and photographs.
Comparison of angular measurements in cephalometrics and photographs.
Abstract:
Introduction: The evaluation of the facial profile is an important factor in any current orthodontic diagnosis and accurate treatment planning is dependent on it....
When to Add Lateral Soft Tissue Balancing?
When to Add Lateral Soft Tissue Balancing?
Lateral patellofemoral (PF) soft tissue abnormalities range from excessive lateral PF tightness (lateral patellar compression syndrome, lateral patellar instability and arthritis),...