Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

P1380 tissue Doppler and speckeled tracking of left ventricle post coarctation repair

View through CrossRef
Abstract Introduction Left ventricular dysfunction was observed after repair of coarctation of the aorta (COA) before development of left ventricular concentric hypertrophy. Aim The aim of this study was to assess the the LV functions after COA repair. Methods Thirty pediatric patients with COA repair underwent echocardiographic examinations using Conventional echocardiography, tissue doppler image (TDI) and 2D-STE. Results The LV systolic functions assessed by TDI and 2-D-STE showed a significant reduction of (S׳׳LW LV, IVA at LW LV, IVA at the septum, longtudinal strain (LS) basal and global radial (GRS) in cases compared to control group . There is significant increase in GCS in cases compared to control group, the conventional Doppler derived MPI of LV in post coarctation repair cases was significantly prolonged compared to control. Analysis of mitral annulus velocities including E", A", E"/A" ratio and E/E′ ratio revealed worsening of the left ventricular diastolic mechanics in the post COA repair cases compared to healthy controls. The E" wave velocity (at the left ventricular lateral wall) was significantly lower in post COA repair in cases compared with controls , E"/A" ratio was significantly lower in post COA repair cases compared with controls . The E/E′ ratio was significantly higher in the post COA repair cases compared to the control group . Conclusions LV systolic and diastolic dysfunction was fount in patient after COA repair. LV systolic function by 2-D-STE Cases Control P value Mean SD mean SD GLS -21.51 2.79 -22.63 2.99 .094 LS basal -19.94 2.83 -22.63 2.99 <0.01 (S) LS Mid -21.08 2.75 -21.87 2.78 .273 LS apical -23.52 4.22 -21.74 4.23 .109 GRS 22.58 5.24 49.01 10.08 <0.01 (S) RS basal 20.92 8.29 43.56 18.95 <0.01 (S) RS mid 25.03 7.59 56.80 14.27 .223 RS apical 21.78 8.34 46.66 15.11 <0.01 (S) GCS -20.09 2.66 -16.73 2.78 <0.01 (S) CS basal -21.49 2.70 -16.98 4.69 <0.01 (S) CS mid -21.27 4.09 -15.83 3.67 <0.01 (S) CS apical -17.51 4.63 -17.39 4.57 .920
Title: P1380 tissue Doppler and speckeled tracking of left ventricle post coarctation repair
Description:
Abstract Introduction Left ventricular dysfunction was observed after repair of coarctation of the aorta (COA) before development of left ventricular concentric hypertrophy.
Aim The aim of this study was to assess the the LV functions after COA repair.
Methods Thirty pediatric patients with COA repair underwent echocardiographic examinations using Conventional echocardiography, tissue doppler image (TDI) and 2D-STE.
Results The LV systolic functions assessed by TDI and 2-D-STE showed a significant reduction of (S׳׳LW LV, IVA at LW LV, IVA at the septum, longtudinal strain (LS) basal and global radial (GRS) in cases compared to control group .
There is significant increase in GCS in cases compared to control group, the conventional Doppler derived MPI of LV in post coarctation repair cases was significantly prolonged compared to control.
Analysis of mitral annulus velocities including E", A", E"/A" ratio and E/E′ ratio revealed worsening of the left ventricular diastolic mechanics in the post COA repair cases compared to healthy controls.
The E" wave velocity (at the left ventricular lateral wall) was significantly lower in post COA repair in cases compared with controls , E"/A" ratio was significantly lower in post COA repair cases compared with controls .
The E/E′ ratio was significantly higher in the post COA repair cases compared to the control group .
Conclusions LV systolic and diastolic dysfunction was fount in patient after COA repair.
LV systolic function by 2-D-STE Cases Control P value Mean SD mean SD GLS -21.
51 2.
79 -22.
63 2.
99 .
094 LS basal -19.
94 2.
83 -22.
63 2.
99 <0.
01 (S) LS Mid -21.
08 2.
75 -21.
87 2.
78 .
273 LS apical -23.
52 4.
22 -21.
74 4.
23 .
109 GRS 22.
58 5.
24 49.
01 10.
08 <0.
01 (S) RS basal 20.
92 8.
29 43.
56 18.
95 <0.
01 (S) RS mid 25.
03 7.
59 56.
80 14.
27 .
223 RS apical 21.
78 8.
34 46.
66 15.
11 <0.
01 (S) GCS -20.
09 2.
66 -16.
73 2.
78 <0.
01 (S) CS basal -21.
49 2.
70 -16.
98 4.
69 <0.
01 (S) CS mid -21.
27 4.
09 -15.
83 3.
67 <0.
01 (S) CS apical -17.
51 4.
63 -17.
39 4.
57 .
920.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
SUMMARY
SUMMARY
SUMMARYThe purpose of the present monograph is to give an account of the distribution of fibrinolytic components in the organism, with special reference to the tissue activator of ...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct Introduction Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Endoscopic anatomy of the ventricles
Endoscopic anatomy of the ventricles
The cerebral ventricles are structures known since antiquity. At the beginning of its description there was a belief that human thoughts and intellect were generated inside the ven...
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
Background: Several methods for fixing inguinal hernias have been documented. Anterior or posterior approaches,open or laparoscopic procedures, may be used for hernia repair. While...
Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
In order to determine the standard Doppler hemodynamic characteristics of the Bjork‐Shiley monostrut aortic prosthesis and the value of the continuity equation to calculate the pro...

Back to Top