Javascript must be enabled to continue!
P1380 tissue Doppler and speckeled tracking of left ventricle post coarctation repair
View through CrossRef
Abstract
Introduction
Left ventricular dysfunction was observed after repair of coarctation of the aorta (COA) before development of left ventricular concentric hypertrophy.
Aim
The aim of this study was to assess the the LV functions after COA repair.
Methods
Thirty pediatric patients with COA repair underwent echocardiographic examinations using Conventional echocardiography, tissue doppler image (TDI) and 2D-STE.
Results
The LV systolic functions assessed by TDI and 2-D-STE showed a significant reduction of (S׳׳LW LV, IVA at LW LV, IVA at the septum, longtudinal strain (LS) basal and global radial (GRS) in cases compared to control group . There is significant increase in GCS in cases compared to control group, the conventional Doppler derived MPI of LV in post coarctation repair cases was significantly prolonged compared to control. Analysis of mitral annulus velocities including E", A", E"/A" ratio and E/E′ ratio revealed worsening of the left ventricular diastolic mechanics in the post COA repair cases compared to healthy controls. The E" wave velocity (at the left ventricular lateral wall) was significantly lower in post COA repair in cases compared with controls , E"/A" ratio was significantly lower in post COA repair cases compared with controls . The E/E′ ratio was significantly higher in the post COA repair cases compared to the control group .
Conclusions
LV systolic and diastolic dysfunction was fount in patient after COA repair.
LV systolic function by 2-D-STE Cases Control P value Mean SD mean SD GLS -21.51 2.79 -22.63 2.99 .094 LS basal -19.94 2.83 -22.63 2.99 <0.01 (S) LS Mid -21.08 2.75 -21.87 2.78 .273 LS apical -23.52 4.22 -21.74 4.23 .109 GRS 22.58 5.24 49.01 10.08 <0.01 (S) RS basal 20.92 8.29 43.56 18.95 <0.01 (S) RS mid 25.03 7.59 56.80 14.27 .223 RS apical 21.78 8.34 46.66 15.11 <0.01 (S) GCS -20.09 2.66 -16.73 2.78 <0.01 (S) CS basal -21.49 2.70 -16.98 4.69 <0.01 (S) CS mid -21.27 4.09 -15.83 3.67 <0.01 (S) CS apical -17.51 4.63 -17.39 4.57 .920
Oxford University Press (OUP)
Title: P1380 tissue Doppler and speckeled tracking of left ventricle post coarctation repair
Description:
Abstract
Introduction
Left ventricular dysfunction was observed after repair of coarctation of the aorta (COA) before development of left ventricular concentric hypertrophy.
Aim
The aim of this study was to assess the the LV functions after COA repair.
Methods
Thirty pediatric patients with COA repair underwent echocardiographic examinations using Conventional echocardiography, tissue doppler image (TDI) and 2D-STE.
Results
The LV systolic functions assessed by TDI and 2-D-STE showed a significant reduction of (S׳׳LW LV, IVA at LW LV, IVA at the septum, longtudinal strain (LS) basal and global radial (GRS) in cases compared to control group .
There is significant increase in GCS in cases compared to control group, the conventional Doppler derived MPI of LV in post coarctation repair cases was significantly prolonged compared to control.
Analysis of mitral annulus velocities including E", A", E"/A" ratio and E/E′ ratio revealed worsening of the left ventricular diastolic mechanics in the post COA repair cases compared to healthy controls.
The E" wave velocity (at the left ventricular lateral wall) was significantly lower in post COA repair in cases compared with controls , E"/A" ratio was significantly lower in post COA repair cases compared with controls .
The E/E′ ratio was significantly higher in the post COA repair cases compared to the control group .
Conclusions
LV systolic and diastolic dysfunction was fount in patient after COA repair.
LV systolic function by 2-D-STE Cases Control P value Mean SD mean SD GLS -21.
51 2.
79 -22.
63 2.
99 .
094 LS basal -19.
94 2.
83 -22.
63 2.
99 <0.
01 (S) LS Mid -21.
08 2.
75 -21.
87 2.
78 .
273 LS apical -23.
52 4.
22 -21.
74 4.
23 .
109 GRS 22.
58 5.
24 49.
01 10.
08 <0.
01 (S) RS basal 20.
92 8.
29 43.
56 18.
95 <0.
01 (S) RS mid 25.
03 7.
59 56.
80 14.
27 .
223 RS apical 21.
78 8.
34 46.
66 15.
11 <0.
01 (S) GCS -20.
09 2.
66 -16.
73 2.
78 <0.
01 (S) CS basal -21.
49 2.
70 -16.
98 4.
69 <0.
01 (S) CS mid -21.
27 4.
09 -15.
83 3.
67 <0.
01 (S) CS apical -17.
51 4.
63 -17.
39 4.
57 .
920.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
P1494 Incidental finding of aortic aneurysm formation following 34 years of coarctation repair by dacron patch aortoplasty
P1494 Incidental finding of aortic aneurysm formation following 34 years of coarctation repair by dacron patch aortoplasty
Abstract
Introduction
Aneurysms are found following all types of surgical repair of aortic coarctation, especially after Dacron ...
Endoscopic anatomy of the ventricles
Endoscopic anatomy of the ventricles
The cerebral ventricles are structures known since antiquity. At the beginning of its description there was a belief that human thoughts and intellect were generated inside the ven...
Baseline Penile Ultrasound and Color Doppler Parameters – A Comparison Between Psychogenic and Vasculogenic Erectile Dysfunction Patients
Baseline Penile Ultrasound and Color Doppler Parameters – A Comparison Between Psychogenic and Vasculogenic Erectile Dysfunction Patients
Background and Objectives: There are many causes of erectile dysfunction (ED) like congenital anomalies, neurological, endocrinal, pharmacological, psychological, pathological or h...
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
AN EXPERIENCE COMPARING INGUINAL HERNIA MESH REPAIR VS DARN REPAIR
Background: Several methods for fixing inguinal hernias have been documented. Anterior or posterior approaches,open or laparoscopic procedures, may be used for hernia repair. While...
Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
In order to determine the standard Doppler hemodynamic characteristics of the Bjork‐Shiley monostrut aortic prosthesis and the value of the continuity equation to calculate the pro...