Javascript must be enabled to continue!
Flexural Behaviour of RC Beams with a Circular Opening at the Flexural Zone and Shear Zone Strengthened Using Steel Plates
View through CrossRef
In this paper, an investigation on the behaviour of RC beams with circular openings in the flexural zone and shear zone strengthened using steel plates is presented. Totally seven beams were cast: a control beam, one beam with a circular opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone, one beam with opening strengthened using the steel plate, one beam with a circular opening of size of 100 mmϕ in the shear zone, one beam with an opening in the shear zone strengthened using the steel plate, one beam with two circular openings of size of 100 mmϕ in the shear zone, and another beam with two openings in the shear zone strengthened using the steel plate. The experiments were conducted in a loading frame of 400 kN capacity. The beams were subjected to two‐point loading. The ultimate load carrying capacity reduced marginally by 1.78% and 2.8% compared to that of the control beam when a circular opening of 100 mmϕ was provided in the flexural zone and shear zone, respectively, and when the opening was strengthened with steel plates, it reduced by 3.04% and 25%, respectively, but the ductility increased when steel plates were provided. Beams with an opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone strengthened with the steel plate can be provided, as the load carrying capacity is only marginally reduced compared to the control beam, and the ductility is more when compared with beams with unstrengthened openings.
Title: Flexural Behaviour of RC Beams with a Circular Opening at the Flexural Zone and Shear Zone Strengthened Using Steel Plates
Description:
In this paper, an investigation on the behaviour of RC beams with circular openings in the flexural zone and shear zone strengthened using steel plates is presented.
Totally seven beams were cast: a control beam, one beam with a circular opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone, one beam with opening strengthened using the steel plate, one beam with a circular opening of size of 100 mmϕ in the shear zone, one beam with an opening in the shear zone strengthened using the steel plate, one beam with two circular openings of size of 100 mmϕ in the shear zone, and another beam with two openings in the shear zone strengthened using the steel plate.
The experiments were conducted in a loading frame of 400 kN capacity.
The beams were subjected to two‐point loading.
The ultimate load carrying capacity reduced marginally by 1.
78% and 2.
8% compared to that of the control beam when a circular opening of 100 mmϕ was provided in the flexural zone and shear zone, respectively, and when the opening was strengthened with steel plates, it reduced by 3.
04% and 25%, respectively, but the ductility increased when steel plates were provided.
Beams with an opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone strengthened with the steel plate can be provided, as the load carrying capacity is only marginally reduced compared to the control beam, and the ductility is more when compared with beams with unstrengthened openings.
Related Results
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
L'acer inoxidable està essent utilitzat de manera creixent en els últims anys als sectors de la indústria i de l'arquitectura gràcies a la seva resistència a la corrosió, facilitat...
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
The dynamic behavior of three-layer composite beams, consisting of concrete slabs and steel beams, is influenced by the structural configuration of each layer as well as the shear ...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Hollow Lightweight Concrete (HLC) beams are gaining popularity due to low cost and low weight as compared with the Solid Lightweight Concrete (SLC) beams. HLC and SLC beams decreas...
Efficiency of Steel Fibers in Improving the Performance of Concrete Beams without Shear Reinforcement
Efficiency of Steel Fibers in Improving the Performance of Concrete Beams without Shear Reinforcement
This research aims to experimentally study the shear strength of steel fiber concrete beams without shear reinforcement (stirrups). Parameters of the study include two compressive ...
Strengthening and Characterization of Existing Reinforced Concrete Beams for Flexure by Effective Utilization of External Steel Elements
Strengthening and Characterization of Existing Reinforced Concrete Beams for Flexure by Effective Utilization of External Steel Elements
Strengthening of structural members is a common practice around the world that may arise due to deterioration of concrete with age or upgradation of design code. This paper aims to...
Shear and flexural behaviour of lightweight self-consolidating concrete beams
Shear and flexural behaviour of lightweight self-consolidating concrete beams
Shear and flexural behaviour of lightweight self-consolidating concrete (LWSCC) beams made of slag aggregates were investigated. Shear reinforced LWSCC beams showed similar shear b...
Shear and flexural behaviour of lightweight self-consolidating concrete beams
Shear and flexural behaviour of lightweight self-consolidating concrete beams
Shear and flexural behaviour of lightweight self-consolidating concrete (LWSCC) beams made of slag aggregates were investigated. Shear reinforced LWSCC beams showed similar shear b...

