A multisample, high-intensity Cs sputter negative ion source for accelerator mass spectrometry applications
View through CrossRef
The development of a high-intensity Cs sputter negative ion source has been completed. The source is equipped with a spherical tungsten ionizer and a target wheel with 18 sample positions. The wheel is separated from the hot sputter region by a gate valve in order to change the samples rapidly and reduce cross contamination. A drive system can push the selected sample into the sputter position and pull it back to the wheel. A metal-ceramic bonded ring is used to support all the parts at sputter potential. The ring is protected from vapor depositions by a specially designed shielding structure, resulting in reliable insulation between the ionizer and the sputter samples. No insulation trouble has occurred during the work for over one year. Beams of 10-μA BeO−, 5-μA Al−, 4.5-μA Fe−, and 350-μA C−, etc. have been delivered. The normalized beam emittance ranges from (2–4) πmm mrad MeV1/2. The memory effect has been evaluated. More than 1000 and 500 times of attenuation for C− and BeO− are observed, respectively, in 10 min after a sample change. The ionization efficiency for 12C− is higher than 5.4% for a graphite sample.
Title: A multisample, high-intensity Cs sputter negative ion source for accelerator mass spectrometry applications
Description:
The development of a high-intensity Cs sputter negative ion source has been completed.
The source is equipped with a spherical tungsten ionizer and a target wheel with 18 sample positions.
The wheel is separated from the hot sputter region by a gate valve in order to change the samples rapidly and reduce cross contamination.
A drive system can push the selected sample into the sputter position and pull it back to the wheel.
A metal-ceramic bonded ring is used to support all the parts at sputter potential.
The ring is protected from vapor depositions by a specially designed shielding structure, resulting in reliable insulation between the ionizer and the sputter samples.
No insulation trouble has occurred during the work for over one year.
Beams of 10-μA BeO−, 5-μA Al−, 4.
5-μA Fe−, and 350-μA C−, etc.
have been delivered.
The normalized beam emittance ranges from (2–4) πmm mrad MeV1/2.
The memory effect has been evaluated.
More than 1000 and 500 times of attenuation for C− and BeO− are observed, respectively, in 10 min after a sample change.
The ionization efficiency for 12C− is higher than 5.
4% for a graphite sample.
Related Results
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Abstract
Introduction
Fine-needle aspiration (FNA) is commonly used to investigate lymphadenopathy of suspected metastatic origin. The current study aims to find the association be...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Electrostatic Accelerators
Electrostatic Accelerators
Abstract
The article contains sections titled:
Introduction
Types of Electrostatic Accelerators
...
Mass Spectrometry of Long‐Lived RadionuclidesUpdate based on the original article by J.S. Becker,Encyclopedia of Analytical Chemistry, © 2000, John Wiley & Sons, Ltd.
Mass Spectrometry of Long‐Lived RadionuclidesUpdate based on the original article by J.S. Becker,Encyclopedia of Analytical Chemistry, © 2000, John Wiley & Sons, Ltd.
AbstractInorganic mass spectrometric methods are powerful multielement analytical techniques for sensitive determination at the trace and ultratrace level, and for isotope ratio me...
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
RationaleLinear ion traps with simplified structure have been widely used in miniaturized mass spectrometers. However, linear ion traps usually have low ion detection efficiency wh...
Ion extraction experiment for electron cyclotron resonance ion source with different magnetic topology
Ion extraction experiment for electron cyclotron resonance ion source with different magnetic topology
Electron cyclotron resonance ion source (ECRIS) for space propulsion requires to be compact and efficient. In this work, ECRIS, which generates magnetic field through permanent mag...
Mass spectrometry of oligosaccharides
Mass spectrometry of oligosaccharides
Abstract
I.
Introduction
162
II.
CHARACTERISTICS OF TANDEM MASS SPECTRA OF CARBOHYDRATES
163
A. Ionization of Carbohydrates
163
1. Electrospray Ionization (E...