Simulation of Effects Off Service Closed Feedwater Heater on Steam Power Plant Performance Using Cycle Tempo 5.0
View through CrossRef
Abstract
Steam power plant needs three important things in its operation, they are safety, reliability, and efficiency. Steam power plant efficiency can be elevated by installing regenerative feedwater heater. Feedwater heater is used to increase the temperature of water needed for combustion process in the boiler, therefore minimizing the fuel used in boiler. Case study is taken from PT. PJB UP Muara Karang Steam Power Plant unit 4 and 5. HPH 4 off service in August 2018 caused thermal efficiency drop about 1.86 % from the previous month. The same case was found in January 2019, in which HPH F off service caused 0.68 % from the previous month. This study’s aim is to find out the effect of off service closed feedwater heater to steam power plant performance using Cycle Tempo 5.0. Steam power plant unit 5 with 172 MW load is modelled on Cycle Tempo. Validation is done by comparing some parameter of simulation result to performance test result with 5% error tolerance. Few variation off service feedwater heater conditions are done by regulating valve for line bypass in order to set feedwater flow into tubes as well as drain flow. NPHR analysis is done by gathering net power and heat needed in boiler for each variation. The result obtained from this study shows that off service feedwater heater cause NPHR enhancement. The highest NPHR increase is achieved when HPH F is on off service condition, with value about 30.58 kCal/kWh. Off service HPH has bigger effect on NPHR increase than LPH on the same condition. Steam power plant efficiency increase continuously with the greater amount of operating feedwater heater. 3 LPH and 2 HPH usage on steam power plant with 172 MW load is assessed as adequate efficient, with all feedwater heater operating at 33.39 %.
Title: Simulation of Effects Off Service Closed Feedwater Heater on Steam Power Plant Performance Using Cycle Tempo 5.0
Description:
Abstract
Steam power plant needs three important things in its operation, they are safety, reliability, and efficiency.
Steam power plant efficiency can be elevated by installing regenerative feedwater heater.
Feedwater heater is used to increase the temperature of water needed for combustion process in the boiler, therefore minimizing the fuel used in boiler.
Case study is taken from PT.
PJB UP Muara Karang Steam Power Plant unit 4 and 5.
HPH 4 off service in August 2018 caused thermal efficiency drop about 1.
86 % from the previous month.
The same case was found in January 2019, in which HPH F off service caused 0.
68 % from the previous month.
This study’s aim is to find out the effect of off service closed feedwater heater to steam power plant performance using Cycle Tempo 5.
Steam power plant unit 5 with 172 MW load is modelled on Cycle Tempo.
Validation is done by comparing some parameter of simulation result to performance test result with 5% error tolerance.
Few variation off service feedwater heater conditions are done by regulating valve for line bypass in order to set feedwater flow into tubes as well as drain flow.
NPHR analysis is done by gathering net power and heat needed in boiler for each variation.
The result obtained from this study shows that off service feedwater heater cause NPHR enhancement.
The highest NPHR increase is achieved when HPH F is on off service condition, with value about 30.
58 kCal/kWh.
Off service HPH has bigger effect on NPHR increase than LPH on the same condition.
Steam power plant efficiency increase continuously with the greater amount of operating feedwater heater.
3 LPH and 2 HPH usage on steam power plant with 172 MW load is assessed as adequate efficient, with all feedwater heater operating at 33.
39 %.
Related Results
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
A new type of Steam separator for CAP1400 Steam Generator is introduced. The result of characteristic experiment, the variables of which contain steam load, saturated water flow an...
PRELIMINARY DESIGN OF RDE FEEDWATER PUMP IMPELLER
PRELIMINARY DESIGN OF RDE FEEDWATER PUMP IMPELLER
Nowadays, pumps are being widely used in the thermal power generation including nuclear power plants. Reaktor Daya Eksperimental (RDE) is a proposed nuclear reactor concept for the...
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
Abstract
In a previous paper (SPE/PS-CIM/CHOA 97850), we presented our findings on a novel cyclic steam injection method that we developed. The Top-Injection Bott...
STEAM DIEGIMO UGDYMO PROCESE IŠŠŪKIAI IR MOKYTOJŲ KOMPETENCIJŲ TOBULINIMO GALIMYBĖS
STEAM DIEGIMO UGDYMO PROCESE IŠŠŪKIAI IR MOKYTOJŲ KOMPETENCIJŲ TOBULINIMO GALIMYBĖS
This article investigates the opportunities for teacher competence development and the challenges that arise when implementing STEAM (Science, Technology, Engineering, Arts, and Ma...
High-Pressure Saturated-Steam Correlations
High-Pressure Saturated-Steam Correlations
Summary
During steam-assisted oil recovery processes, the thermal properties of saturated steam are required in the computation of heat losses and quality changes...
Steam-CO Recovery Processes For Bottom Water Oil Reservoirs
Steam-CO Recovery Processes For Bottom Water Oil Reservoirs
Abstract
Based on Pujol and Boberg's scaling criteria, a series of experiments on steam-CO2 injection strategies was conducted in a high temperature, high pressur...
Downhole Steam Generation for Green Heavy Oil Recovery
Downhole Steam Generation for Green Heavy Oil Recovery
Abstract
The ultimate target of heavy oil recovery is to enhance oil mobility by transferring steam's thermal energy to the oil phase, incrementing its temperatur...
Vacuum Insulated Tubing Efficiency for Offshore Steam Injection: Case Study from Emeraude Field Congo
Vacuum Insulated Tubing Efficiency for Offshore Steam Injection: Case Study from Emeraude Field Congo
Abstract