Javascript must be enabled to continue!
An empirical analysis of residential meter degradation in Gauteng Province, South Africa
View through CrossRef
Understanding the degradation rates of water meters assists utilities in making informed management decisions regarding meter replacement programmes and meter technology selection. This research evaluated the performance of 200 residential meters of two different technologies commonly used in Gauteng, South Africa, namely velocity meters and volumetric meters. This was done by conducting empirical meter testing in a verification laboratory and evaluating the degradation accuracy of each meter technology based on age and volume. Results indicate that velocity meters experience an accuracy degradation rate of approximately −1.13% per 1 000 kL of volume passed through the meter and an inferred initial error of −10.80%. Meter accuracy was not strongly related to age of the velocity meters tested. Volumetric meters did not exhibit a strong link with either age or accumulated volume, indicated by a loose grouping of results. These results indicate that accumulated volume of a velocity meter is a more reliable predictor of accuracy than age, and should be used when planning replacement strategies for velocity meters. Additionally, the lack of predictable degradation rates related to either age or accumulated volume for volumetric meters indicates that the accuracy of volumetric meters is primarily affected by other external factors, such as particulates or entrained air in the water network. These findings will assist utility managers in predicting the accuracy of their meter fleet and in making informed decisions regarding meter replacement.
Title: An empirical analysis of residential meter degradation in Gauteng Province, South Africa
Description:
Understanding the degradation rates of water meters assists utilities in making informed management decisions regarding meter replacement programmes and meter technology selection.
This research evaluated the performance of 200 residential meters of two different technologies commonly used in Gauteng, South Africa, namely velocity meters and volumetric meters.
This was done by conducting empirical meter testing in a verification laboratory and evaluating the degradation accuracy of each meter technology based on age and volume.
Results indicate that velocity meters experience an accuracy degradation rate of approximately −1.
13% per 1 000 kL of volume passed through the meter and an inferred initial error of −10.
80%.
Meter accuracy was not strongly related to age of the velocity meters tested.
Volumetric meters did not exhibit a strong link with either age or accumulated volume, indicated by a loose grouping of results.
These results indicate that accumulated volume of a velocity meter is a more reliable predictor of accuracy than age, and should be used when planning replacement strategies for velocity meters.
Additionally, the lack of predictable degradation rates related to either age or accumulated volume for volumetric meters indicates that the accuracy of volumetric meters is primarily affected by other external factors, such as particulates or entrained air in the water network.
These findings will assist utility managers in predicting the accuracy of their meter fleet and in making informed decisions regarding meter replacement.
Related Results
Afrikanske smede
Afrikanske smede
African Smiths Cultural-historical and sociological problems illuminated by studies among the Tuareg and by comparative analysisIn KUML 1957 in connection with a description of sla...
A model for the prevention of work-place violence towards public service emergency care providers in Gauteng province
A model for the prevention of work-place violence towards public service emergency care providers in Gauteng province
Workplace violence is an alarming world-wide phenomenon that also affects healthcare providers. However, among healthcare providers, Prehospital Emergency Care Providers (PECPs) ar...
Domestic water meter optimal replacement period to minimize water revenue loss
Domestic water meter optimal replacement period to minimize water revenue loss
Water meter under-registration results in apparent losses and lost revenue for municipalities. Municipalities should scientifically determine the optimal replacement periods for th...
South Africa
South Africa
The Republic of South Africa, known as South Africa, occupies the most southern tip of Africa with a coastline stretching from the border of Namibia on the Atlantic Ocean (south-we...
New species of the Afrotropical spider genus Cheiramiona Lotz & Dippenaar-Schoeman (Araneae: Eutichuridae)
New species of the Afrotropical spider genus Cheiramiona Lotz & Dippenaar-Schoeman (Araneae: Eutichuridae)
Twenty-three new species of the Afrotropical sac spider genus Cheiramiona Lotz & Dippenaar-Schoeman, 1999 are described: C. baviaan sp. nov. (♀, South Africa), C. boschrandensi...
Mindy Calling: Size, Beauty, Race in The Mindy Project
Mindy Calling: Size, Beauty, Race in The Mindy Project
When characters in the Fox Television sitcom The Mindy Project call Mindy Lahiri fat, Mindy sees it as a case of misidentification. She reminds the character that she is a “petite ...
Cancer diagnostic service use in people with HIV in South Africa: a cross-sectional study
Cancer diagnostic service use in people with HIV in South Africa: a cross-sectional study
AbstractObjectiveThe objective of this study was to map place of cancer diagnosis in relation to Human Immunodeficiency Virus (HIV) care centre among people with HIV (PWH) within S...
Diabetic control and compliance using HbA1C testing guidelines in public healthcare facilities of Gauteng province, South Africa
Diabetic control and compliance using HbA1C testing guidelines in public healthcare facilities of Gauteng province, South Africa
ABSTRACTObjectiveThis study aimed at evaluating diabetic control and compliance with testing guidelines, across healthcare facilities of Gauteng Province, South Africa as well as f...