Javascript must be enabled to continue!
Unsupported electrospun membrane for water desalination using direct contact membrane distillation
View through CrossRef
AbstractIn this project, an unsupported electrospun poly(vinylidene fluoride)‐co‐hexafluoropropylene (PVDF‐HFP) membrane was used for water desalination using direct contact membrane distillation (DCMD). The membrane was electrospun using a laboratory‐scale machine with multiple nozzles that was developed in‐house. Critical process parameters, including the applied voltage and polymer concentration, were optimized to obtain bead‐free electrospun membranes with fiber diameters less than 300 nm. To improve the membrane thermal stability and performance, the selected electrospun membrane was heat‐pressed at 160°C. The untreated and heat‐pressed membranes were tested in a DCMD setup at different feed temperatures (60, 70, and 80°C) and feed flow rates (0.4, 0.6, and 0.8 L/min), while maintaining the permeate temperature and flow rate at 20°C and 0.2 L/min, respectively. The modified electrospun membrane exhibited a very high permeate flux (>37.5 kg/m2/h) and a salt rejection rate of 99.99% at a feed temperature of 70°C. The performance of the heat‐pressed unsupported PVDF‐HFP electrospun membrane was nearly identical to a commercially available polytetrafluoroethylene (PTFE) supported membrane. These promising results demonstrate that relatively low‐cost electrospun membranes can be easily produced and successfully used in DCMD to minimize the capital cost and increase the energy efficiency of the process.
Title: Unsupported electrospun membrane for water desalination using direct contact membrane distillation
Description:
AbstractIn this project, an unsupported electrospun poly(vinylidene fluoride)‐co‐hexafluoropropylene (PVDF‐HFP) membrane was used for water desalination using direct contact membrane distillation (DCMD).
The membrane was electrospun using a laboratory‐scale machine with multiple nozzles that was developed in‐house.
Critical process parameters, including the applied voltage and polymer concentration, were optimized to obtain bead‐free electrospun membranes with fiber diameters less than 300 nm.
To improve the membrane thermal stability and performance, the selected electrospun membrane was heat‐pressed at 160°C.
The untreated and heat‐pressed membranes were tested in a DCMD setup at different feed temperatures (60, 70, and 80°C) and feed flow rates (0.
4, 0.
6, and 0.
8 L/min), while maintaining the permeate temperature and flow rate at 20°C and 0.
2 L/min, respectively.
The modified electrospun membrane exhibited a very high permeate flux (>37.
5 kg/m2/h) and a salt rejection rate of 99.
99% at a feed temperature of 70°C.
The performance of the heat‐pressed unsupported PVDF‐HFP electrospun membrane was nearly identical to a commercially available polytetrafluoroethylene (PTFE) supported membrane.
These promising results demonstrate that relatively low‐cost electrospun membranes can be easily produced and successfully used in DCMD to minimize the capital cost and increase the energy efficiency of the process.
Related Results
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
An Investigation into Hydrophobic Membrane Fouling in Desalination Using Membrane Distillation Technology
An Investigation into Hydrophobic Membrane Fouling in Desalination Using Membrane Distillation Technology
Demand for freshwater supplies is continuously increasing globally to the extent where some parts of the world became highly water stressed. In particular, the Arabian Gulf states ...
Desalination by Membrane Distillation
Desalination by Membrane Distillation
At present, around 25% of water desalination processes are based on distillation. Similar to classical distillation, membrane distillation is a phased-change process in which a hyd...
A Critical Review of Alternative Desalination Technologies for Smart Waterflooding
A Critical Review of Alternative Desalination Technologies for Smart Waterflooding
Summary
The importance of tuning injection-water chemistry for upstream is moving beyond formation-damage control/water incompatibility to increasing oil recovery fr...
Desalination
Desalination
Abstract
Desalination is the production of fresh potable water from a saline water source (seawater or brackish water) via membrane separation or evaporation. Desalinatio...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Desalination and Long-Haul Water Transfer as a Water Supply for Dallas, Texas: A Case Study of the Energy-Water Nexus in Texas
Desalination and Long-Haul Water Transfer as a Water Supply for Dallas, Texas: A Case Study of the Energy-Water Nexus in Texas
As existing water supplies become increasingly strained in some locations, water planners turn to alternative options to quench cities’ thirst. Among these options for inland citie...
Water Desalination
Water Desalination
AbstractThis article addresses water availability and use with special emphasis on the role and current level of technology of water desalination. The major desalination processes,...

