Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Detecting Moments of Stress from Measurements of Wearable Physiological Sensors

View through CrossRef
There is a rich repertoire of methods for stress detection using various physiological signals and algorithms. However, there is still a gap in research efforts moving from laboratory studies to real-world settings. A small number of research has verified when a physiological response is a reaction to an extrinsic stimulus of the participant’s environment in real-world settings. Typically, physiological signals are correlated with the spatial characteristics of the physical environment, supported by video records or interviews. The present research aims to bridge the gap between laboratory settings and real-world field studies by introducing a new algorithm that leverages the capabilities of wearable physiological sensors to detect moments of stress (MOS). We propose a rule-based algorithm based on galvanic skin response and skin temperature, combing empirical findings with expert knowledge to ensure transferability between laboratory settings and real-world field studies. To verify our algorithm, we carried out a laboratory experiment to create a “gold standard” of physiological responses to stressors. We validated the algorithm in real-world field studies using a mixed-method approach by spatially correlating the participant’s perceived stress, geo-located questionnaires, and the corresponding real-world situation from the video. Results show that the algorithm detects MOS with 84% accuracy, showing high correlations between measured (by wearable sensors), reported (by questionnaires and eDiary entries), and recorded (by video) stress events. The urban stressors that were identified in the real-world studies originate from traffic congestion, dangerous driving situations, and crowded areas such as tourist attractions. The presented research can enhance stress detection in real life and may thus foster a better understanding of circumstances that bring about physiological stress in humans.
Title: Detecting Moments of Stress from Measurements of Wearable Physiological Sensors
Description:
There is a rich repertoire of methods for stress detection using various physiological signals and algorithms.
However, there is still a gap in research efforts moving from laboratory studies to real-world settings.
A small number of research has verified when a physiological response is a reaction to an extrinsic stimulus of the participant’s environment in real-world settings.
Typically, physiological signals are correlated with the spatial characteristics of the physical environment, supported by video records or interviews.
The present research aims to bridge the gap between laboratory settings and real-world field studies by introducing a new algorithm that leverages the capabilities of wearable physiological sensors to detect moments of stress (MOS).
We propose a rule-based algorithm based on galvanic skin response and skin temperature, combing empirical findings with expert knowledge to ensure transferability between laboratory settings and real-world field studies.
To verify our algorithm, we carried out a laboratory experiment to create a “gold standard” of physiological responses to stressors.
We validated the algorithm in real-world field studies using a mixed-method approach by spatially correlating the participant’s perceived stress, geo-located questionnaires, and the corresponding real-world situation from the video.
Results show that the algorithm detects MOS with 84% accuracy, showing high correlations between measured (by wearable sensors), reported (by questionnaires and eDiary entries), and recorded (by video) stress events.
The urban stressors that were identified in the real-world studies originate from traffic congestion, dangerous driving situations, and crowded areas such as tourist attractions.
The presented research can enhance stress detection in real life and may thus foster a better understanding of circumstances that bring about physiological stress in humans.

Related Results

Wearable Sensor Application for Integrated Early Warning and Health Surveillance
Wearable Sensor Application for Integrated Early Warning and Health Surveillance
Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health u...
Editors' words
Editors' words
<p class="Text">Developing materials is basic in wearable technology. The materials had better be stretchable, comfortable, bendable, portable, light and flexible enough to m...
Dynamic Scheduled Access Medium Access Control for Emerging Wearable Applications
Dynamic Scheduled Access Medium Access Control for Emerging Wearable Applications
Context and MotivationWearable technology is emerging as one of the key enablers for the internet of everything (IoE). The technology is getting mature by every day with more appli...
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
The development of flexible and textile-based wearable pressure sensors has provided the opportunity of continuous and real time measurement of human physiological and biomechanica...
(Invited) Tellurene Wearable Sensors
(Invited) Tellurene Wearable Sensors
The development of wearable sensors for continually monitoring biomarkers is a promising alternative to the costly tools currently utilized in healthcare. Two-dimensional (2D) mate...
Research and sustainable design of wearable sensor for clothing based on body area network
Research and sustainable design of wearable sensor for clothing based on body area network
AbstractThe body area network (BAN) is composed of every wearable device network on the body to share information and data, which is applied in medical and health, especially in th...
Nafion Based Two Electrode CO Sensor
Nafion Based Two Electrode CO Sensor
The aim of this work is to determine the optimal platinum loading for the preparation of membrane-based electrochemical sensors for carbon monoxide detection. Platinum is a require...

Back to Top