Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

View through CrossRef
In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU). The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.
Title: Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System
Description:
In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning.
The indoor terminal device is the radiant induction-unit (RIDU).
The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed.
The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment.
With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied.
Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel.
The characteristics of the radiation and convection heat transfer of the RIDU were studied.
The total heat exchange of the RIDU can be 16.
5% greater than that of the traditional plate-type radiant terminal.

Related Results

Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
Radiant cooling systems are commonly applied in commercial applications because of their energy-saving potential. This potential can be further enhanced by evaluating the cooling p...
Dynamic Behavior of Aircraft Cabin and Air Conditioning System
Dynamic Behavior of Aircraft Cabin and Air Conditioning System
<div class="htmlview paragraph">During cruise flight, aircraft cabin environmental conditions are different from that found in a building. The relative humidity, mean radiant...
Neural substrates underlying human delay and trace eyeblink conditioning
Neural substrates underlying human delay and trace eyeblink conditioning
Classical conditioning paradigms, such as trace conditioning, in which a silent period elapses between the offset of the conditioned stimulus (CS) and the delivery of the unconditi...
PELATIHAN TEKNIK PENDINGIN AIR CONDITIONER (AC) DI PT WAHLRAB MUKANING BATAM
PELATIHAN TEKNIK PENDINGIN AIR CONDITIONER (AC) DI PT WAHLRAB MUKANING BATAM
ABSTRAK Permintaan AC juga terus meningkat lantaran kegiatan work from home (WFH) masih menjadi kebiasaan bagi sebagian masyarakat Indonesia di tengah meredanya pandemi. Dam...
Thermal Performance of Wall Systems Utilizing Radiant Barriers
Thermal Performance of Wall Systems Utilizing Radiant Barriers
Typical brick veneer wall assemblies contain an air space to provide drainage inside the wall. This air cavity results in heat transfer through the wall via conduction, convection,...
Surface Roughness of Er, Cr: YSGG Laser Etched Enamel Compared to Acid Etching: An In Vitro Study
Surface Roughness of Er, Cr: YSGG Laser Etched Enamel Compared to Acid Etching: An In Vitro Study
Objectives: Erbium-based lasers have been used in dentistry with different parameters for enamel conditioning with controversial results on the optimum parameter. This st...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...