Javascript must be enabled to continue!
Results of CO2 Laser-assisted Deep Sclerectomy as Compared With Conventional Deep Sclerectomy
View through CrossRef
Purpose:
To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients.
Materials and Methods:
Patients who underwent primary filtration surgery with CO2 laser system at the time interval between July 2010 and April 2011 were identified, their medical files were reviewed, and their results were compared with matched control group who underwent classic NPDS with intrascleral implant at the same time period. Intraocular pressure (IOP) was measured at baseline, 1 week, and 3, 6, 12, 18, and 24 months, respectively. Main outcome measures were: IOP, use of supplemental medical therapy, and failure (5 mm Hg>IOP>18 mm Hg, reoperation for glaucoma, or loss of light perception).
Results:
A total of 58 patients were reviewed, including 27 in the CLASS group and 31 in the NPDS group. For the CLASS group the follow-up (mean±SD) was 20.7±6.8 months, the mean preoperative IOP was 23.3±8.2 mm Hg (range, 10 to 38 mm Hg), and the mean number of antiglaucoma medication before surgery was 3.0±1.0 (range, 1 to 4). At final follow-up visits, the mean IOP was 11.7±3.1 mm Hg (range, 6 to 19 mm Hg), and the mean number of antiglaucoma medication was reduced to 1.0±1.6 (P<0.0003). The complete success rate (IOP≤18 mm Hg without antiglaucoma medication) was 73% and the qualified success rate (IOP≤18 mm Hg with/without antiglaucoma medication) was 96%. For the control group the mean follow-up was 17.6±6.7 months, the mean preoperative IOP was 23.1±7.3 mm Hg (range, 14 to 44 mm Hg), and the mean number of antiglaucoma medication before surgery was 3.0±0.8 (range, 1 to 4). At final follow-up visits, the IOP was 13.3±3.6 mm Hg (range, 8 to 20 mm Hg), and the mean number of antiglaucoma medication was reduced to 0.7±1.1 (P<0.0004). The complete success rate and the qualified success rate were 71% and 89%, respectively.
Conclusions:
A new technique using a CO2-laser ablation system allows precise and easy creation of the scleral space and ablation of Schlemm canal. This technique has been shown to be as efficient as the standard NPDS surgery in terms of IOP-lowering effect. This would render the deep sclerectomy an easier glaucoma surgery.
Ovid Technologies (Wolters Kluwer Health)
Title: Results of CO2 Laser-assisted Deep Sclerectomy as Compared With Conventional Deep Sclerectomy
Description:
Purpose:
To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients.
Materials and Methods:
Patients who underwent primary filtration surgery with CO2 laser system at the time interval between July 2010 and April 2011 were identified, their medical files were reviewed, and their results were compared with matched control group who underwent classic NPDS with intrascleral implant at the same time period.
Intraocular pressure (IOP) was measured at baseline, 1 week, and 3, 6, 12, 18, and 24 months, respectively.
Main outcome measures were: IOP, use of supplemental medical therapy, and failure (5 mm Hg>IOP>18 mm Hg, reoperation for glaucoma, or loss of light perception).
Results:
A total of 58 patients were reviewed, including 27 in the CLASS group and 31 in the NPDS group.
For the CLASS group the follow-up (mean±SD) was 20.
7±6.
8 months, the mean preoperative IOP was 23.
3±8.
2 mm Hg (range, 10 to 38 mm Hg), and the mean number of antiglaucoma medication before surgery was 3.
0±1.
0 (range, 1 to 4).
At final follow-up visits, the mean IOP was 11.
7±3.
1 mm Hg (range, 6 to 19 mm Hg), and the mean number of antiglaucoma medication was reduced to 1.
0±1.
6 (P<0.
0003).
The complete success rate (IOP≤18 mm Hg without antiglaucoma medication) was 73% and the qualified success rate (IOP≤18 mm Hg with/without antiglaucoma medication) was 96%.
For the control group the mean follow-up was 17.
6±6.
7 months, the mean preoperative IOP was 23.
1±7.
3 mm Hg (range, 14 to 44 mm Hg), and the mean number of antiglaucoma medication before surgery was 3.
0±0.
8 (range, 1 to 4).
At final follow-up visits, the IOP was 13.
3±3.
6 mm Hg (range, 8 to 20 mm Hg), and the mean number of antiglaucoma medication was reduced to 0.
7±1.
1 (P<0.
0004).
The complete success rate and the qualified success rate were 71% and 89%, respectively.
Conclusions:
A new technique using a CO2-laser ablation system allows precise and easy creation of the scleral space and ablation of Schlemm canal.
This technique has been shown to be as efficient as the standard NPDS surgery in terms of IOP-lowering effect.
This would render the deep sclerectomy an easier glaucoma surgery.
Related Results
Rapid Large-scale Trapping of CO2 via Dissolution in US Natural CO2 Reservoirs
Rapid Large-scale Trapping of CO2 via Dissolution in US Natural CO2 Reservoirs
Naturally occurring CO2 reservoirs across the USA are critical natural analogues of long-term CO2 storage in the subsurface over geological timescales and provide valuable insights...
Design And Operation Of The Levelland Unit CO2 Injection Facility
Design And Operation Of The Levelland Unit CO2 Injection Facility
Abstract
The Levelland CO2 Facility provides CO2 storageand handling capacity for the five CO2 injection pilots located in the Levelland Unit. Facilities pilots l...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract
Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Impact of CCUS Impurities on Dense Phase CO2 Pipeline Surface Engineering Design
Impact of CCUS Impurities on Dense Phase CO2 Pipeline Surface Engineering Design
Abstract
Numerous CO2 injection pipeline applications have been developed and implemented in the past decades in the UAE and all around the globe. Transporting the C...
Evaluation of Kaolinite and activated carbon performance for CO2 capture
Evaluation of Kaolinite and activated carbon performance for CO2 capture
Global climate change is one of the major threats facing the world today and can be due to increased atmospheric concentrations of greenhouse gases (GHGs), such as carbon dioxide (...
Preliminary Assessment of CO2 Storage Potential in the H-59 Block in Jilin Oilfield CCS Project
Preliminary Assessment of CO2 Storage Potential in the H-59 Block in Jilin Oilfield CCS Project
The block H-59 in the Daqingzijing region was selected as a pilot site for the first stage of the CCS project in Jilin oilfield after an extensive assessment. This block is a light...
Aquifer Management to Accelerate CO2 Dissolution and Trapping
Aquifer Management to Accelerate CO2 Dissolution and Trapping
Abstract
Bulk phase CO2 injection can provide substantive reduction in CO2 emissions only if additional brine is produced out of the system to address relevant risk ...