Javascript must be enabled to continue!
Research on Shield-Out Synchronous Grouting Technology and its Influence on the Backfill Synchronous Grouting
View through CrossRef
Shield-out space and shield-end space in shield construction are mainly due to the over-excavation caused by the shield machine structure, which result in the ground surface subsidence. This paper introduced the shield-out synchronous grouting technology that used for temporary filling of shield-out space between shield and strata. The influence of shield-out synchronous grouting on backfill synchronous grouting is researched by the laboratory tests, and the surface subsidence controlling effect is studied by an engineering application. The results shows that the clay shock, shield-out grouting material, weakens the setting time, fluidity, UCS, and flexural strength of cemented mortar, though the bleeding and hardening properties are improved. It is suggested that the volume ratio of clay shock to cemented mortar that in appropriate for shield construction should be less than 1/5, and the cemented mortar with higher strength should be adopted. The shield-out synchronous grouting technology can effectively limit the surface subsidence during shield construction without any reinforcement of surrounding buildings.
Title: Research on Shield-Out Synchronous Grouting Technology and its Influence on the Backfill Synchronous Grouting
Description:
Shield-out space and shield-end space in shield construction are mainly due to the over-excavation caused by the shield machine structure, which result in the ground surface subsidence.
This paper introduced the shield-out synchronous grouting technology that used for temporary filling of shield-out space between shield and strata.
The influence of shield-out synchronous grouting on backfill synchronous grouting is researched by the laboratory tests, and the surface subsidence controlling effect is studied by an engineering application.
The results shows that the clay shock, shield-out grouting material, weakens the setting time, fluidity, UCS, and flexural strength of cemented mortar, though the bleeding and hardening properties are improved.
It is suggested that the volume ratio of clay shock to cemented mortar that in appropriate for shield construction should be less than 1/5, and the cemented mortar with higher strength should be adopted.
The shield-out synchronous grouting technology can effectively limit the surface subsidence during shield construction without any reinforcement of surrounding buildings.
Related Results
Experimental research on the flow law of the grouting fluid in an annular gap between a non-soil-squeezing PHC pipe pile wall and a hole wall
Experimental research on the flow law of the grouting fluid in an annular gap between a non-soil-squeezing PHC pipe pile wall and a hole wall
The bearing capacity of drilling with pre-stressed concrete pile cased pile (hereafter referred to as DPC pile) is closely related to the grouting effect on an annular gap between ...
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
Abstract
Background
Epetraborole (EBO) is an orally available, bacterial leucyl transfer RNA synthetase inhibitor that concentra...
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
Abstract
Background
SUL-DUR is a β-lactam/β-lactamase inhibitor combination in development for the treatment of ABC infections, ...
STUDY ON A NEW DESIGN OF GROUTING PUMP FOR MANAGING WATER INRUSH IN KARST TUNNELS
STUDY ON A NEW DESIGN OF GROUTING PUMP FOR MANAGING WATER INRUSH IN KARST TUNNELS
The low flow rate and efficiency of existing grouting pumps such as piston pumps and diaphragm pumps result in difficulty in managing sudden water and slurry discharges. In this st...
Study of the Effect of Grouting Material Strength on Semiflexible Pavement Material
Study of the Effect of Grouting Material Strength on Semiflexible Pavement Material
In this study, cement mortars with different strengths are poured into the large void matrix asphalt macadam material as a semiflexible pavement (SFP) material and the experimental...
The mitigation of surface subsidence in coal mines
The mitigation of surface subsidence in coal mines
Overlying-separation layer grouting technology refers to manufacturing grouting by mixing water, fly ash and other materials on ground in proportion, and then injecting into stratu...
Grouting Fractured Coal Permeability Evolution Based on Industrial CT Scanning
Grouting Fractured Coal Permeability Evolution Based on Industrial CT Scanning
Gas extraction from coal seams in China faces various middle-term and long-term problems, such as the poor sealing quality and low extraction rate. The mean gas extraction concentr...
Migration mechanism of grouting slurry and permeability reduction in mining fractured rock mass
Migration mechanism of grouting slurry and permeability reduction in mining fractured rock mass
Abstract
In order to solve the water and gas discharge hazard caused by gob water and harmful gases (such as CO), the method of grouting overburden fractures is a...