A Comparison of Haemodynamic Responses between Clinical Assessments Guided Tracheal Intubation and Neuromuscular Block Monitoring Guided Tracheal Intubation
View through CrossRef
BACKGROUND During the induction of general anaesthesia (GA), laryngoscopy and endotracheal intubation produce significant nociceptive stimuli, which frequently results in inadvertent activation of the sympathetic nervous system. To blunt this pressor response, many drugs are successfully used. However, administration of an additional drug might cause adverse haemodynamic effects or might unnecessarily increase the depth of anaesthesia. Hence, a non-pharmacological measure to reduce the response is preferred. In this study, we wanted tocompare haemodynamic responses between clinical assessment-guided tracheal intubation and neuromuscular block monitoring-guided tracheal intubation. METHODS An observational study was conducted on 62 patients aged 18 – 60 years old belonging to American Soceity of Anaesthesiologist (ASA) I & II posted for surgeries under general anaesthesia were allotted to 2 groups of 31 each. In Group C patients, the trachea was intubated after the clinical judgment of jaw muscle relaxation. In Group M patients, the trachea was intubated after train of four counts became zero in adductor pollicis muscle. Changes in heart rate [HR], mean arterial blood pressure [MAP], Krieg’s intubation score, time between the administration of a neuromuscular blocking agent and endotracheal intubation were recorded. The collected data was analysed by mean, standard deviation, frequency, percentage, ttest and chi square test. RESULTS HR and mean arterial pressure were significantly higher in Group C as compared to Group M after laryngoscopy and tracheal intubation (P < 0.05). The mean time required for intubation was significantly shorter in Group C compared to Group M (179.52 ± 2 s vs. 358.19 ± 55 s). Excellent and good intubation conditions were observed in all Group M patients, whereas 24 out of 31 patients (77 %) in Group C showed excellent and good intubation conditions. CONCLUSIONS Haemodynamic responses to laryngoscopy and tracheal intubation can be significantly attenuated if tracheal intubation is performed following complete paralysis of laryngeal muscles, detected by neuromuscular monitoring of adductor pollicis muscle. KEY WORDS Laryngoscopy, Intubation, Haemodynamic Responses, Stress Response, Neuromuscular Monitor.
Akshantala Enterprises Private Limited
Title: A Comparison of Haemodynamic Responses between Clinical Assessments Guided Tracheal Intubation and Neuromuscular Block Monitoring Guided Tracheal Intubation
Description:
BACKGROUND During the induction of general anaesthesia (GA), laryngoscopy and endotracheal intubation produce significant nociceptive stimuli, which frequently results in inadvertent activation of the sympathetic nervous system.
To blunt this pressor response, many drugs are successfully used.
However, administration of an additional drug might cause adverse haemodynamic effects or might unnecessarily increase the depth of anaesthesia.
Hence, a non-pharmacological measure to reduce the response is preferred.
In this study, we wanted tocompare haemodynamic responses between clinical assessment-guided tracheal intubation and neuromuscular block monitoring-guided tracheal intubation.
METHODS An observational study was conducted on 62 patients aged 18 – 60 years old belonging to American Soceity of Anaesthesiologist (ASA) I & II posted for surgeries under general anaesthesia were allotted to 2 groups of 31 each.
In Group C patients, the trachea was intubated after the clinical judgment of jaw muscle relaxation.
In Group M patients, the trachea was intubated after train of four counts became zero in adductor pollicis muscle.
Changes in heart rate [HR], mean arterial blood pressure [MAP], Krieg’s intubation score, time between the administration of a neuromuscular blocking agent and endotracheal intubation were recorded.
The collected data was analysed by mean, standard deviation, frequency, percentage, ttest and chi square test.
RESULTS HR and mean arterial pressure were significantly higher in Group C as compared to Group M after laryngoscopy and tracheal intubation (P < 0.
05).
The mean time required for intubation was significantly shorter in Group C compared to Group M (179.
52 ± 2 s vs.
358.
19 ± 55 s).
Excellent and good intubation conditions were observed in all Group M patients, whereas 24 out of 31 patients (77 %) in Group C showed excellent and good intubation conditions.
CONCLUSIONS Haemodynamic responses to laryngoscopy and tracheal intubation can be significantly attenuated if tracheal intubation is performed following complete paralysis of laryngeal muscles, detected by neuromuscular monitoring of adductor pollicis muscle.
KEY WORDS Laryngoscopy, Intubation, Haemodynamic Responses, Stress Response, Neuromuscular Monitor.
Related Results
Awake Tracheal Intubation Is Associated with Fewer Adverse Events in Critical Care Patients than Anaesthetised Tracheal Intubation
Awake Tracheal Intubation Is Associated with Fewer Adverse Events in Critical Care Patients than Anaesthetised Tracheal Intubation
Background: Tracheal intubation in critical care is a high-risk procedure requiring significant expertise and airway strategy modification. We hypothesise that awake tracheal intub...
Intubating Conditions and Tracheal Intubation at First Attempt Without Neuromuscular Blockade Using Sevoflurane: Comparison of Clinical Versus Bispectral Index Monitored Depth of Anaesthesia
Intubating Conditions and Tracheal Intubation at First Attempt Without Neuromuscular Blockade Using Sevoflurane: Comparison of Clinical Versus Bispectral Index Monitored Depth of Anaesthesia
Tracheal intubation, which is typically made possible by neuromuscular blocking agents, is an essential part of airway management in critical care and anaesthesia. To lessen relate...
Flexible Lightwand–guided Tracheal Intubation with the Intubating Laryngeal Mask Fastrach TMin Adults after Unpredicted Failed Laryngoscope-guided Tracheal Intubation
Flexible Lightwand–guided Tracheal Intubation with the Intubating Laryngeal Mask Fastrach TMin Adults after Unpredicted Failed Laryngoscope-guided Tracheal Intubation
Background
The authors determined the efficacy of using the intubating laryngeal mask airway Fastrach (ILM) as a ventilatory device and aid to flexible lightwand-guided...
Comparative evaluation of Intubating Laryngeal Mask Airway (ILMA), I-gel and Ambu AuraGain for blind tracheal intubation in adults
Comparative evaluation of Intubating Laryngeal Mask Airway (ILMA), I-gel and Ambu AuraGain for blind tracheal intubation in adults
Background and Aims:
The supraglottic airway devices (SADs) that allow direct (without an intermediary device like Aintree or airway exchange catheters) trachea...
Treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia
Treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia
Objective. To describe treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia. Material and methods. There were 91 patients wi...
Correlation between clinical risk factors and tracheal intubation difficulty in infants with Pierre-Robin syndrome: A retrospective study
Correlation between clinical risk factors and tracheal intubation difficulty in infants with Pierre-Robin syndrome: A retrospective study
Abstract
Background: Difficult tracheal intubation is a common problem encountered by anesthesiologists in the clinic. This study was conducted to assess the difficulty of...
Correlation between clinical risk factors and tracheal intubation difficulty in infants with Pierre-Robin syndrome: A retrospective study
Correlation between clinical risk factors and tracheal intubation difficulty in infants with Pierre-Robin syndrome: A retrospective study
Abstract
Background: Difficult tracheal intubation is a common problem encountered by anesthesiologists in the clinic. This study was conducted to assess the difficulty of...
TRACHEAL INTUBATION
TRACHEAL INTUBATION
Introduction: Haemodynamic response to direct laryngoscopy and tracheal intubation has always been concern especially in cardiac patients. The use of fiberoptic bronchoscope for en...