Protecting Fibrinogen with Rutin during UVC Irradiation for Viral Inactivation

View through CrossRef
Abstract— Fibrinogen solutions were irradiated with UVC (254 nm) to inactivate contaminating viruses. In order to protect fibrinogen during UVC irradiation, 0.5 m M rutin was added prior to UVC exposure and subsequently removed during processing. Viral kill by 0.1 J/cm 2 UVC resulted in the following inactivation values (log 10): non‐lipid‐enveloped viruses: Parvo 5.5; encephalomyocarditis virus 6.5; hepatitis A virus 6.5: lipid‐enveloped viruses: human immunodeficiency virus 5.7; vesicular stomatitis virus 5.7. Fibrinogen irradiated with 0.5 m M rutin did not significantly differ from unirradiated material in terms of clot time and breaking strength. In the absence of rutin, UVC irradiation of fibrinogen at similar fluence led to loss of solubility, increased clot time and the cleavage of fibrino‐peptides that reacted with dinitro‐phenyl hydrazine as a test for ketonic carbonyl groups. High‐performance liquid chromatography and mass spectrometry data showed that rutin exposed to UVC formed numerous breakdown, oxidation and combinational products. Experiments with 3 H‐rutin showed that after UVC irradiation, subsequent processing by a C18 resin and alcohol precipitation removed >99% rutin, representing <10 ppm rutin in the final fibrinogen preparations. Residual 3 H‐rutin was not covalently bonded to the fibrinogen. Immunochemical studies with rabbit antisera to UVC irradiated (with rutin) fibrinogen showed the absence of neoimmungens. By all measures, rutin prevents fibrinogen degradation during virucidal UVC irradiation.
Title: Protecting Fibrinogen with Rutin during UVC Irradiation for Viral Inactivation
Description:
Abstract— Fibrinogen solutions were irradiated with UVC (254 nm) to inactivate contaminating viruses.
In order to protect fibrinogen during UVC irradiation, 0.
5 m M rutin was added prior to UVC exposure and subsequently removed during processing.
Viral kill by 0.
1 J/cm 2 UVC resulted in the following inactivation values (log 10): non‐lipid‐enveloped viruses: Parvo 5.
5; encephalomyocarditis virus 6.
5; hepatitis A virus 6.
5: lipid‐enveloped viruses: human immunodeficiency virus 5.
7; vesicular stomatitis virus 5.
7.
Fibrinogen irradiated with 0.
5 m M rutin did not significantly differ from unirradiated material in terms of clot time and breaking strength.
In the absence of rutin, UVC irradiation of fibrinogen at similar fluence led to loss of solubility, increased clot time and the cleavage of fibrino‐peptides that reacted with dinitro‐phenyl hydrazine as a test for ketonic carbonyl groups.
High‐performance liquid chromatography and mass spectrometry data showed that rutin exposed to UVC formed numerous breakdown, oxidation and combinational products.
Experiments with 3 H‐rutin showed that after UVC irradiation, subsequent processing by a C18 resin and alcohol precipitation removed >99% rutin, representing <10 ppm rutin in the final fibrinogen preparations.
Residual 3 H‐rutin was not covalently bonded to the fibrinogen.
Immunochemical studies with rabbit antisera to UVC irradiated (with rutin) fibrinogen showed the absence of neoimmungens.
By all measures, rutin prevents fibrinogen degradation during virucidal UVC irradiation.

Related Results

The Effectiveness of Commercial Household Ultraviolet C Germicidal Devices in Thailand
The Effectiveness of Commercial Household Ultraviolet C Germicidal Devices in Thailand
Abstract Ultraviolet C (UVC), also called ultraviolet germicidal irradiation (UVGI), is known for its effective air, water, and surface disinfectant properties. With the ri...
Kinetics of methylene blue degradation in VUV/UVC irradiation process and the role of hydroxyl radical
Kinetics of methylene blue degradation in VUV/UVC irradiation process and the role of hydroxyl radical
Abstract A series of investigations have been carried out to study the decomposition of methylene blue (MB) by the VUV/UVC based AOPs. However, MB degradation by VUV/UVC di...
The effectiveness of commercial household ultraviolet C germicidal devices in Thailand
The effectiveness of commercial household ultraviolet C germicidal devices in Thailand
Abstract Ultraviolet C (UVC), or ultraviolet germicidal irradiation, is known for its effective air, water, and surface disinfectant properties. With the rise of global awa...
Irradiation of UVC LED at 277 nm inactivates coronaviruses by photodegradation of spike protein
Irradiation of UVC LED at 277 nm inactivates coronaviruses by photodegradation of spike protein
SUMMARY To interrupt SARS-CoV-2 transmission chains, Ultraviolet-C (UVC) irradiation has emerged as a potential disinfection tool to aid in blocking the spread of c...
UVC Light Simulation for Room Disinfection System
UVC Light Simulation for Room Disinfection System
Viruses are minuscule parasites that have gained notoriety for causing diseases. However, these harmful pathogens can be inactivated using Ultraviolet-C (UVC) radiation that has a ...
KADAR FIBRINOGEN SEBAGAI FAKTOR PROGNOSTIK PASIEN PERDARAHAN INTRASEREBRAL SPONTAN
KADAR FIBRINOGEN SEBAGAI FAKTOR PROGNOSTIK PASIEN PERDARAHAN INTRASEREBRAL SPONTAN
         FIBRINOGEN VALUE AS PROGNOSTIC FACTOR IN SPONTANEOUS INTRACEREBRAL HEMORRHAGEABSTRACTIntroduction: Spontaneous intracerebral haemorrhage (SIH) refers as spontaneous bleedi...
Deteksi Simultan Kuersetin dan Rutin Menggunakan Screen-Printed Carbon Electrode Termodifikasi Grafena
Deteksi Simultan Kuersetin dan Rutin Menggunakan Screen-Printed Carbon Electrode Termodifikasi Grafena
Kuersetin dan rutin merupakan senyawa antioksidan alami yang termasuk golongan flavonoid. Senyawa ini dapat dideteksi dengan beberapa teknik analisis, salah satunya dengan teknik e...