Javascript must be enabled to continue!
An optimized method for neutron dose evaluation based on 24Na activity distribution in the human body
View through CrossRef
Abstract
The neutron dose resulting from external irradiation can be evaluated by measuring the counts of characteristic γ rays produced by 24Na in the human body. The detection geometry with the highest detection efficiency for measuring the whole-body 24Na activity has not been studied. In this work, the MCNP code is used to calculate the spatial distribution of 24Na in the human body irradiated by neutrons with different energies in different irradiation geometries. The fluence distribution of 24Na characteristic γ rays on the body surface is calculated. The counts of 24Na characteristic γ rays induced by monochromatic neutron irradiation are simulated to fit the scenarios of neutron irradiation by a continuous energy spectrum neutron. When the spontaneous neutrons from 252Cf with 1Gy dose irradiate the human body, (3.63–4.35) × 1010 24Na atoms are produced. The lower detection limit for the neutron absorption dose is reduced from ∼100 to less than 1 mGy when the radiation detector is placed over the back of the human body close to the liver. The relative error between the measured counts of 24Na characteristic γ rays caused by 252Cf neutron irradiation and the counts fitted by monochromatic neutron irradiation data is less than 5.7%. The neutron dose received from a continuous energy spectrum neutron can be acquired quickly and accurately by weighted summing of the data for monochromatic neutron irradiations calculated in this paper, which is more convenient and practical than the previous method.
Title: An optimized method for neutron dose evaluation based on 24Na activity distribution in the human body
Description:
Abstract
The neutron dose resulting from external irradiation can be evaluated by measuring the counts of characteristic γ rays produced by 24Na in the human body.
The detection geometry with the highest detection efficiency for measuring the whole-body 24Na activity has not been studied.
In this work, the MCNP code is used to calculate the spatial distribution of 24Na in the human body irradiated by neutrons with different energies in different irradiation geometries.
The fluence distribution of 24Na characteristic γ rays on the body surface is calculated.
The counts of 24Na characteristic γ rays induced by monochromatic neutron irradiation are simulated to fit the scenarios of neutron irradiation by a continuous energy spectrum neutron.
When the spontaneous neutrons from 252Cf with 1Gy dose irradiate the human body, (3.
63–4.
35) × 1010 24Na atoms are produced.
The lower detection limit for the neutron absorption dose is reduced from ∼100 to less than 1 mGy when the radiation detector is placed over the back of the human body close to the liver.
The relative error between the measured counts of 24Na characteristic γ rays caused by 252Cf neutron irradiation and the counts fitted by monochromatic neutron irradiation data is less than 5.
7%.
The neutron dose received from a continuous energy spectrum neutron can be acquired quickly and accurately by weighted summing of the data for monochromatic neutron irradiations calculated in this paper, which is more convenient and practical than the previous method.
Related Results
Tijelo u opusu Janka Polića Kamova
Tijelo u opusu Janka Polića Kamova
The doctoral disertation is dedicated to the concept of the body in the works of Janko Polić Kamov. The body is approached as a signifier system on the basis of which numerous and ...
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
AbstractIntroductionCancer is one of the major medical problems threatening human health. Breast cancer is the most prevalent type of cancer in women. Reports indicate that treatme...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED]Prima Weight Loss Dragons Den UK :-Obesity is a not kidding medical issue brought about by devouring an excessive amount of fat, eating terrible food sources, and practi...
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED]Prima Weight Loss Dragons Den UK :-Obesity is a not kidding medical issue brought about by devouring an excessive amount of fat, eating terrible food sources, and practi...
Update of the radiation environment measurement results aboard ExoMars TGO in May 2018-June 202
Update of the radiation environment measurement results aboard ExoMars TGO in May 2018-June 202
AbstractThe dosimetric telescope Liulin-MO [1] for measuring the radiation environment onboard the ExoMars TGO is a module of the Fine Resolution Epithermal Neutron Detector (FREND...
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
Unconventional oil and gas resources, such as tight oil and gas, have become indispensably succeeding energy sources in nowadays. At the stage of exploration, gas saturation is ess...