Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

MEASUREMENT OF THE HALF-PERIOD OF POLONIUM 213

View through CrossRef
In the recently discovered (4n + 1) radioactive series, bismuth 213 transforms to polonium 213 by β-emission. The latter rapidly transforms by α-emission to lead 209. The present paper describes a measurement of the half-period of polonium 213. A preparation of radium 225 was placed between two Geiger–Müller counters. One detected β-particles while the other detected α and β-particles. Coincidences were counted with a modified Rossi circuit. The pulse-width on the grid of one of the tubes of the coincidence unit was made variable, while the pulse-width on the other remained fixed. The pulse-width associated with the counter that responded only to β-particles was chosen to be variable. Coincidences were counted as a function of the pulse-width. Corrections were made for accidental coincidences and exact coincidences arising from other causes. The final value for the half-period T of polonium 213 is T = 4.2 ± 0.8 μsec. A subsidiary experiment to determine the half-period of thorium C′ gave the value T = 0.34 ± 0.06 μsec. in reasonable agreement with measurements by other workers.
Canadian Science Publishing
Title: MEASUREMENT OF THE HALF-PERIOD OF POLONIUM 213
Description:
In the recently discovered (4n + 1) radioactive series, bismuth 213 transforms to polonium 213 by β-emission.
The latter rapidly transforms by α-emission to lead 209.
The present paper describes a measurement of the half-period of polonium 213.
A preparation of radium 225 was placed between two Geiger–Müller counters.
One detected β-particles while the other detected α and β-particles.
Coincidences were counted with a modified Rossi circuit.
The pulse-width on the grid of one of the tubes of the coincidence unit was made variable, while the pulse-width on the other remained fixed.
The pulse-width associated with the counter that responded only to β-particles was chosen to be variable.
Coincidences were counted as a function of the pulse-width.
Corrections were made for accidental coincidences and exact coincidences arising from other causes.
The final value for the half-period T of polonium 213 is T = 4.
2 ± 0.
8 μsec.
A subsidiary experiment to determine the half-period of thorium C′ gave the value T = 0.
34 ± 0.
06 μsec.
in reasonable agreement with measurements by other workers.

Related Results

Uranium, Polonium-218, and Polonium-214 Concentrations in Serum Samples of Cancer Patients at Al-Najaf Governorate
Uranium, Polonium-218, and Polonium-214 Concentrations in Serum Samples of Cancer Patients at Al-Najaf Governorate
This research examines the concentrations of uranium (UC), polonium of POW (218Po and 214Po on the wall of the irradiation container), and polonium of POS (218Po and 214Po on the s...
Polonium: Radionuclides
Polonium: Radionuclides
Abstract All polonium isotopes are radioactive with only three having appreciable half‐lives: 208 Po, 209 Po,...
Polonium: Radionuclides
Polonium: Radionuclides
Abstract All polonium isotopes are radioactive with only three having appreciable half‐lives: 208 Po, 209 Po,...
Practical Concerns In Metering Fluids From Production Operations
Practical Concerns In Metering Fluids From Production Operations
Abstract Accurate measurement of oil and gas is of vital concern. Measurement of these vapor and liquid streams by mass, volumetric, and energy techniques are rev...
Air, 4. Pollution Monitoring
Air, 4. Pollution Monitoring
AbstractThe article contains sections titled:1.Introduction2.Measurement Planning2.1.Types of Air Pollution Monitoring2.2.Planning of Pollution Measurements2.2.1.Measurement Networ...
The Effect of Clinical Knee Measurement in Children with Genu Varus
The Effect of Clinical Knee Measurement in Children with Genu Varus
Abstract Introduction Children with genu varus needs frequent assessment and follow up that may need several radiographies. This study investigates the effectiveness of the clinica...
Large-scale absolute distance measurement using inter-mode beat of a femtosecond laser
Large-scale absolute distance measurement using inter-mode beat of a femtosecond laser
Large-scale absolute distance measurement system with high accuracy plays a significant role in science and engineering applications. In many fields such as aerospace technology, l...

Back to Top