Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Abstract 4367277: Intracardiac Echocardiography Use and Outcomes Following Catheter Ablation of Ventricular Tachycardia: A Meta-Analysis

View through CrossRef
Introduction: Intracardiac echocardiography (ICE) has emerged as a potentially valuable tool during ventricular tachycardia (VT), offering real-time visualization of cardiac anatomy and the catheter–tissue interface. Despite its theoretical benefits, data on the efficacy of ICE-guided VT ablation remains limited. We conducted a meta-analysis to systematically evaluate the impact of ICE on procedural success, complication rates, and long-term outcomes in VT ablation. Methods: A total of 1,616 studies were identified through a systematic search of PubMed and Embase up to May 2025. Three observational studies met the inclusion criteria and were included in the analysis. Primary outcomes included cardiovascular (CV)-related readmission, ventricular tachycardia (VT)-related readmission, major complications (cardiac tamponade, vascular injury, thromboembolism, major bleeding requiring transfusion), and repeat VT ablation. Using the Mantel-Haenszel method, a random-effects model was employed to calculate odds ratio (ORs) with corresponding 95% confidence intervals (CIs) for statistical significance. Higgins' I^2 was used to analyze heterogeneity. Results: Three studies involving 4,473 patients were included in the analysis. Ventricular tachycardia (VT) ablation guided by intracardiac echocardiography (ICE) was associated with a significantly lower incidence of cardiovascular (CV)-related readmissions (OR 0.78, 95% CI 0.67–0.92; p = 0.002). While VT ablation with ICE did not show any significant difference in major complications (OR 0.79, 95% CI 0.39–1.60; p = 0.5) , VT-related readmissions (OR 0.85, 95% CI 0.69–1.04; p = 0.10), and repeat VT ablation (OR 1.08, 95% CI 0.73–1.58; p = 0.71). Conclusion: Intracardiac echocardiography (ICE) use during catheter ablation of ventricular tachycardia (VT) showed reduced incidence of CV-related readmissions, however there were no significant statistical differences in VT- related readmissions, repeat VT ablation and major complications between the two groups. Further observational studies and RCTs are needed to better understand the benefits of intracardiac echocardiography in catheter ablation of ventricular tachycardia.
Title: Abstract 4367277: Intracardiac Echocardiography Use and Outcomes Following Catheter Ablation of Ventricular Tachycardia: A Meta-Analysis
Description:
Introduction: Intracardiac echocardiography (ICE) has emerged as a potentially valuable tool during ventricular tachycardia (VT), offering real-time visualization of cardiac anatomy and the catheter–tissue interface.
Despite its theoretical benefits, data on the efficacy of ICE-guided VT ablation remains limited.
We conducted a meta-analysis to systematically evaluate the impact of ICE on procedural success, complication rates, and long-term outcomes in VT ablation.
Methods: A total of 1,616 studies were identified through a systematic search of PubMed and Embase up to May 2025.
Three observational studies met the inclusion criteria and were included in the analysis.
Primary outcomes included cardiovascular (CV)-related readmission, ventricular tachycardia (VT)-related readmission, major complications (cardiac tamponade, vascular injury, thromboembolism, major bleeding requiring transfusion), and repeat VT ablation.
Using the Mantel-Haenszel method, a random-effects model was employed to calculate odds ratio (ORs) with corresponding 95% confidence intervals (CIs) for statistical significance.
Higgins' I^2 was used to analyze heterogeneity.
Results: Three studies involving 4,473 patients were included in the analysis.
Ventricular tachycardia (VT) ablation guided by intracardiac echocardiography (ICE) was associated with a significantly lower incidence of cardiovascular (CV)-related readmissions (OR 0.
78, 95% CI 0.
67–0.
92; p = 0.
002).
While VT ablation with ICE did not show any significant difference in major complications (OR 0.
79, 95% CI 0.
39–1.
60; p = 0.
5) , VT-related readmissions (OR 0.
85, 95% CI 0.
69–1.
04; p = 0.
10), and repeat VT ablation (OR 1.
08, 95% CI 0.
73–1.
58; p = 0.
71).
Conclusion: Intracardiac echocardiography (ICE) use during catheter ablation of ventricular tachycardia (VT) showed reduced incidence of CV-related readmissions, however there were no significant statistical differences in VT- related readmissions, repeat VT ablation and major complications between the two groups.
Further observational studies and RCTs are needed to better understand the benefits of intracardiac echocardiography in catheter ablation of ventricular tachycardia.

Related Results

Case report: Para Hisian Atrial Tachycardia
Case report: Para Hisian Atrial Tachycardia
Atrial tachycardia accounts for around 10% of supraventricular tachycardias (1). Atrial      tachycardia can either be focal or macrorenentrant. Focal AT usually start at a focal p...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract Introduction  Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
Introduction: Novel ablation catheters equipped with mini-electrodes (ME) offer high resolution mapping for target tissue. This study aimed to evaluate the mappin...
The evaluation of irrigating ablation catheter in the treatment for severely symptomatic premature ventricular contractions
The evaluation of irrigating ablation catheter in the treatment for severely symptomatic premature ventricular contractions
Introduction Radiofrequency catheter ablation (RFCA) of symptomatic ventricular premature contractions has been reported to be a safe and effective treatment opti...
Ablation of left posterior fascicular tachycardia during sinus rhythm under the guide of non-contact array
Ablation of left posterior fascicular tachycardia during sinus rhythm under the guide of non-contact array
Aims To explore the effectiveness and safety of catheter ablation for left posterior fascicular ventricular tachycardia under the guide of Ensite3000/array. ...
Radiofrequency Catheter Ablation in Children with Supraventricular Tachycardias: Intermediate Term Follow up Results
Radiofrequency Catheter Ablation in Children with Supraventricular Tachycardias: Intermediate Term Follow up Results
The Purpose of the Study Radiofrequency (RF) catheter ablation represents an important advance in the management of children with cardiac arrhythmias and has ra...

Back to Top