Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Analysis of Beam-Column Joint Reinforced with Cross Bars according to SK SNI T-15-1991-03 on Cyclic Loads

View through CrossRef
The primary structural component supporting the other structural loads in a building is the beam-column joint. It is considered a critical area of a building which needs to be accurately designed to ensure energy is dissipated properly during the occurrence of an earthquake. Beam-column joint has the ability to offer a proper structure required to transform cyclic loads in the inelastic region but also has a direct impact on the components connected to it during the occurrence of any failure. This is one of the reasons the beam-column connection needs to be designed carefully. Therefore, this study focused on designing a beam-column joint with reinforcement according to SK SNI T-15-1991 in order to withstand cyclic loads. The test specimen used was observed to have a concrete compressive strength of 19.17 MPa while the dimension of the beam was 120 x 30 x 40 cm and the column was 30 x 30 x 200 cm, having 8Ø13.4 mm bars with 310.03 MPa yield strength (fy) as well as Ø9.8-100 mm stirrup reinforcement with (fy) 374.59 MPa. The test was initiated through the provision of 0.75 mm, 1.5 mm, 3 mm, 6 mm, 12 mm, 24 mm monotonic cyclic loads at the end of the beam up to the moment the specimen cracked. A maximum load of 68.35 kN for the compression and 49.92 kN for the tension was required to attain the cyclic load capacity. The maximum load was attained at 50.98 mm displacement. Furthermore, beam-column with 23.93 mm displacement caused a reduction in capacity. Meanwhile, the load at 24 mm produced the cycle's highest dissipation energy of 13.25 but this can be increased through the addition of stirrups to provide stiffness in the joint. The stiffness value was also observed to have increased after the structural repairs.
Title: The Analysis of Beam-Column Joint Reinforced with Cross Bars according to SK SNI T-15-1991-03 on Cyclic Loads
Description:
The primary structural component supporting the other structural loads in a building is the beam-column joint.
It is considered a critical area of a building which needs to be accurately designed to ensure energy is dissipated properly during the occurrence of an earthquake.
Beam-column joint has the ability to offer a proper structure required to transform cyclic loads in the inelastic region but also has a direct impact on the components connected to it during the occurrence of any failure.
This is one of the reasons the beam-column connection needs to be designed carefully.
Therefore, this study focused on designing a beam-column joint with reinforcement according to SK SNI T-15-1991 in order to withstand cyclic loads.
The test specimen used was observed to have a concrete compressive strength of 19.
17 MPa while the dimension of the beam was 120 x 30 x 40 cm and the column was 30 x 30 x 200 cm, having 8Ø13.
4 mm bars with 310.
03 MPa yield strength (fy) as well as Ø9.
8-100 mm stirrup reinforcement with (fy) 374.
59 MPa.
The test was initiated through the provision of 0.
75 mm, 1.
5 mm, 3 mm, 6 mm, 12 mm, 24 mm monotonic cyclic loads at the end of the beam up to the moment the specimen cracked.
A maximum load of 68.
35 kN for the compression and 49.
92 kN for the tension was required to attain the cyclic load capacity.
The maximum load was attained at 50.
98 mm displacement.
Furthermore, beam-column with 23.
93 mm displacement caused a reduction in capacity.
Meanwhile, the load at 24 mm produced the cycle's highest dissipation energy of 13.
25 but this can be increased through the addition of stirrups to provide stiffness in the joint.
The stiffness value was also observed to have increased after the structural repairs.

Related Results

Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Cyclic Behaviour of Beam-Column Joints with Corbels Under In-Plane Lateral Loads
Cyclic Behaviour of Beam-Column Joints with Corbels Under In-Plane Lateral Loads
Abstract Corbels appearance in precast beam-column joints has a significant impact on the behaviour of the transition zone at the end of the beam which could help in...
Electroacupuncture combined with subanesthetic alfaxalone as a novel target for alleviating neuropathic pain
Electroacupuncture combined with subanesthetic alfaxalone as a novel target for alleviating neuropathic pain
Abstract Introduction: Neuropathic pain severely affects patients' quality of life. Limited treatments offer relief but often involve long-term u...
Reinforced concrete beam‐columns anchored with headed bars subjected to reversed cyclic loading: Experimental and numerical investigation
Reinforced concrete beam‐columns anchored with headed bars subjected to reversed cyclic loading: Experimental and numerical investigation
AbstractPast seismic events have shown poor performance of reinforced concrete (RC) moment resisting frames, due to failure of beam‐column joints, attributed to insufficient anchor...
Structural behavior of ultra-high performance concrete corner beam-column joint under bidirectional loading
Structural behavior of ultra-high performance concrete corner beam-column joint under bidirectional loading
Abstract In the past few decades, extensive experimental research has been focused on studying the performance of beam-column joints under cyclic load due to their involvem...

Back to Top