Javascript must be enabled to continue!
Nonclinical Safety of SHP 826 (BAX 826), a Next Generation Extended Half-Life Recombinant Factor VIII Product
View through CrossRef
Abstract
Hemophilia A is a rare genetic bleeding disorder caused by missing or defective factor VIII (FVIII), a crucial factor in blood coagulation. Baxalta Innovations / Shire is currently developing SHP 826 (BAX 826), as the next generation EHL rFVIII replacement for the treatment of hemophilia A. SHP 826 is the first EHL rFVIII to utilize novel technology in which polysialic acid (PSA) is conjugated to Baxalta's licensed rFVIII product (Advate) to extend the circulation half-life of FVIII.
The potential toxicity of SHP 826 was evaluated in Sprague Dawley rats and cynomolgus monkeys. Acute toxicity was assessed in a dose-escalation study in monkeys that were intravenously administered 350 and 1800 IU rFVIII/kg SHP 826. Repeat dose toxicity was assessed in rats at doses of 80, 350, and 800 IU rFVIII/kg, in monkeys at doses of 800 IU rFVIII/kg every 5 days for 4 weeks, and in monkeys at doses of 80, 350, or 600 IU rFVIII/kg every five days for 31 days. Cardiovascular and respiratory safety was assessed in one of the repeat dose toxicity studies in monkeys. The thrombogenic potential of SHP 826 was evaluated after a single intravenous administration in rabbits (900 rFVIII/kg BW) using a stasis model developed by Wessler et al. (1959). The licensed rFVIII product was used as a comparator in the acute toxicity study and in the Wessler test.
Parameters evaluated included local tolerance at the injection site, body weight, clinical pathology, blood gas analysis, analysis of neutralizing and binding antibodies in plasma, organ weight, necropsy observation, and histopathological evaluation. In addition, seminology (epididymal and testicular sperm) was assessed in rats, and urinalysis, ophthalmic and telemetric cardiovascular examination and respiratory rate measurement was performed in monkeys.
SHP 826 showed a favorable safety/toxicity profile in both species used, with no abnormalities directly caused by test item administration noted in vivo or during clinical or histopathological examination. The NOAEL was set to the highest dose tested in each study (i.e. 800 IU rFVIII/kg BW in rats and 600 IU rFVIII/ kg BW in monkeys). Toxicokinetic evaluation indicated dose proportional PK. Exposure to FVIII decreased after repeated treatments due to appearance of anti-FVIII antibodies in both species. Development of anti-FVIII antibodies is an expected immune response after repeated application of heterologous proteins, and is not predictive of any potential for triggering development of anti-FVIII antibodies in humans.
Safety pharmacology studies with SHP 826 revealed no evidence of thrombogenic potential in rabbits. SHP 826 administered intravenously was well tolerated in conscious telemetered cynomolgous monkeys (part of the repeat dose toxicity study) and did not cause any adverse clinical, cardiovascular, or respiratory effects.
The results of these safety studies indicate sufficient safety margins to support the anticipated maximum clinical dose, and therefore entry into clinical development.
Disclosures
Ehrlich: Shire: Employment. Leidenmuehler:Shire: Employment. Dietrich:Shire: Employment. Hoebarth:Shire: Employment. Ruthsatz:Shire: Employment. Turecek:Shire: Employment. Wolfsegger:Shire: Employment, Equity Ownership. Weber:Shire: Employment. Gritsch:Shire: Employment. Hoellriegl:Shire: Employment. Turecek:Shire: Employment.
Title: Nonclinical Safety of SHP 826 (BAX 826), a Next Generation Extended Half-Life Recombinant Factor VIII Product
Description:
Abstract
Hemophilia A is a rare genetic bleeding disorder caused by missing or defective factor VIII (FVIII), a crucial factor in blood coagulation.
Baxalta Innovations / Shire is currently developing SHP 826 (BAX 826), as the next generation EHL rFVIII replacement for the treatment of hemophilia A.
SHP 826 is the first EHL rFVIII to utilize novel technology in which polysialic acid (PSA) is conjugated to Baxalta's licensed rFVIII product (Advate) to extend the circulation half-life of FVIII.
The potential toxicity of SHP 826 was evaluated in Sprague Dawley rats and cynomolgus monkeys.
Acute toxicity was assessed in a dose-escalation study in monkeys that were intravenously administered 350 and 1800 IU rFVIII/kg SHP 826.
Repeat dose toxicity was assessed in rats at doses of 80, 350, and 800 IU rFVIII/kg, in monkeys at doses of 800 IU rFVIII/kg every 5 days for 4 weeks, and in monkeys at doses of 80, 350, or 600 IU rFVIII/kg every five days for 31 days.
Cardiovascular and respiratory safety was assessed in one of the repeat dose toxicity studies in monkeys.
The thrombogenic potential of SHP 826 was evaluated after a single intravenous administration in rabbits (900 rFVIII/kg BW) using a stasis model developed by Wessler et al.
(1959).
The licensed rFVIII product was used as a comparator in the acute toxicity study and in the Wessler test.
Parameters evaluated included local tolerance at the injection site, body weight, clinical pathology, blood gas analysis, analysis of neutralizing and binding antibodies in plasma, organ weight, necropsy observation, and histopathological evaluation.
In addition, seminology (epididymal and testicular sperm) was assessed in rats, and urinalysis, ophthalmic and telemetric cardiovascular examination and respiratory rate measurement was performed in monkeys.
SHP 826 showed a favorable safety/toxicity profile in both species used, with no abnormalities directly caused by test item administration noted in vivo or during clinical or histopathological examination.
The NOAEL was set to the highest dose tested in each study (i.
e.
800 IU rFVIII/kg BW in rats and 600 IU rFVIII/ kg BW in monkeys).
Toxicokinetic evaluation indicated dose proportional PK.
Exposure to FVIII decreased after repeated treatments due to appearance of anti-FVIII antibodies in both species.
Development of anti-FVIII antibodies is an expected immune response after repeated application of heterologous proteins, and is not predictive of any potential for triggering development of anti-FVIII antibodies in humans.
Safety pharmacology studies with SHP 826 revealed no evidence of thrombogenic potential in rabbits.
SHP 826 administered intravenously was well tolerated in conscious telemetered cynomolgous monkeys (part of the repeat dose toxicity study) and did not cause any adverse clinical, cardiovascular, or respiratory effects.
The results of these safety studies indicate sufficient safety margins to support the anticipated maximum clinical dose, and therefore entry into clinical development.
Disclosures
Ehrlich: Shire: Employment.
Leidenmuehler:Shire: Employment.
Dietrich:Shire: Employment.
Hoebarth:Shire: Employment.
Ruthsatz:Shire: Employment.
Turecek:Shire: Employment.
Wolfsegger:Shire: Employment, Equity Ownership.
Weber:Shire: Employment.
Gritsch:Shire: Employment.
Hoellriegl:Shire: Employment.
Turecek:Shire: Employment.
Related Results
Abstract 1773: The tyrosine phosphatase, SHP-2, is involved in regulating PD-L1 expression in non-small cell lung cancer
Abstract 1773: The tyrosine phosphatase, SHP-2, is involved in regulating PD-L1 expression in non-small cell lung cancer
Abstract
Immune checkpoint inhibitors (ICIs), specifically those which target the T-cell surface receptor Programmed Cell Death-1 (PD-1) and its ligand, Programme...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Nonclinical Assessment of Bax 604 (FEIBA STAR) - Reduced Volume Reconstitution & Higher Infusion Rate
Nonclinical Assessment of Bax 604 (FEIBA STAR) - Reduced Volume Reconstitution & Higher Infusion Rate
Abstract
To support the BAX 604 (FEIBA STAR) clinical study assessing different infusion rates and low volume reconstitution, the following nonclinical program was i...
Anatomy of the superior hypogastric plexus and its relevance to anterior lumbar interbody fusion
Anatomy of the superior hypogastric plexus and its relevance to anterior lumbar interbody fusion
OBJECTIVE
Retrograde ejaculation (RE) is a known complication of anterior lumbar interbody fusion (ALIF) and results from injury to the superior hypogastric ple...
Critical Role of Src and SHP-2 in sst2 Somatostatin Receptor-mediated Activation of SHP-1 and Inhibition of Cell Proliferation
Critical Role of Src and SHP-2 in sst2 Somatostatin Receptor-mediated Activation of SHP-1 and Inhibition of Cell Proliferation
The G protein-coupled sst2 somatostatin receptor acts as a negative cell growth regulator. Sst2 transmits antimitogenic signaling by recruiting and activating the tyrosine phosphat...
Activating PTPN11 Mutants Promote Myelomonocytic Differentiation Due to Altered Hematopoietic Lineage-Specific Transcription Factor Expression.
Activating PTPN11 Mutants Promote Myelomonocytic Differentiation Due to Altered Hematopoietic Lineage-Specific Transcription Factor Expression.
Abstract
Juvenile myelomonocytic leukemia (JMML) is a lethal disease of young children characterized by pathologic overproduction of myelomonocytic cells. Mutations ...
L'insertion membranaire de la protéine pro-apoptotique Bax est un processus muti-étapes dépendant de TOM22
L'insertion membranaire de la protéine pro-apoptotique Bax est un processus muti-étapes dépendant de TOM22
L'apoptose est le processus par lequel les cellules animales s'autodétruisent en réponse à un signal de mort (par exemple, des dommages à l'ADN). La voie intrinsèque est contrôlée ...
ChREBP Rather than SHP Regulates Hepatic VLDL Secretion
ChREBP Rather than SHP Regulates Hepatic VLDL Secretion
The regulation of hepatic very-low-density lipoprotein (VLDL) secretion plays an important role in the pathogenesis of dyslipidemia and fatty liver diseases. VLDL is controlled by ...