Javascript must be enabled to continue!
Functionalization of Screw Implants with Superelastic Structured Nitinol Anchoring Elements
View through CrossRef
Abstract
Demographic change is leading to a increase in the number of osteoporotic patients, so that a rethink is required in implantology in order to be able to guarantee adequate anchoring stability in the bone. The functional modification of conventional standard screw implants by the use of superelastic, structured Ti6Al4V anchoring elements promises great potential for increasing anchoring stability. For this purpose, conventional screw implants were mechanically machined and extended so that structured-superelastic-positionable-Ti6Al4V anchoring elements could be used. The set-up of the anchoring elements was investigated in CT studies in an artificial bone. In a subsequent handling test, the handling of the function samples was evaluated under surgical conditions. The anchorage stability to standard screw implants was investigated in a final pull-out test according to "ASTM F543".The functionalization of conventional screw implants with structured superelastic Ti6Al4V anchoring elements is technically realizable. It has been demonstrated that the anchoring elements can be set up in the artificial bone without any problems. The anchorage mechanism is easy to handle under operating conditions and the anchoring elements have no negative impact on the surgical procedure. It was shown that, compared to conventional standard screws, more mechanical work is required to remove the functional patterns completely from the bone.In summary, it was shown that conventional standard screw implants can be functionalized with Ti6Al4V structured NiTi anchoring elements and are suitable for orthopedic and neurosurgical use. A first biomechanical test showed that the anchoring stability can be increased by the anchoring elements.
Springer Science and Business Media LLC
Title: Functionalization of Screw Implants with Superelastic Structured Nitinol Anchoring Elements
Description:
Abstract
Demographic change is leading to a increase in the number of osteoporotic patients, so that a rethink is required in implantology in order to be able to guarantee adequate anchoring stability in the bone.
The functional modification of conventional standard screw implants by the use of superelastic, structured Ti6Al4V anchoring elements promises great potential for increasing anchoring stability.
For this purpose, conventional screw implants were mechanically machined and extended so that structured-superelastic-positionable-Ti6Al4V anchoring elements could be used.
The set-up of the anchoring elements was investigated in CT studies in an artificial bone.
In a subsequent handling test, the handling of the function samples was evaluated under surgical conditions.
The anchorage stability to standard screw implants was investigated in a final pull-out test according to "ASTM F543".
The functionalization of conventional screw implants with structured superelastic Ti6Al4V anchoring elements is technically realizable.
It has been demonstrated that the anchoring elements can be set up in the artificial bone without any problems.
The anchorage mechanism is easy to handle under operating conditions and the anchoring elements have no negative impact on the surgical procedure.
It was shown that, compared to conventional standard screws, more mechanical work is required to remove the functional patterns completely from the bone.
In summary, it was shown that conventional standard screw implants can be functionalized with Ti6Al4V structured NiTi anchoring elements and are suitable for orthopedic and neurosurgical use.
A first biomechanical test showed that the anchoring stability can be increased by the anchoring elements.
Related Results
Features of the Structural Design of Welded Joints of Superelastic Nitinol Wires
Features of the Structural Design of Welded Joints of Superelastic Nitinol Wires
The object of the study is a permanent joint of thin wires made of nitinol alloy. The problem of ensuring the formation of a joint of wires made of nitinol alloy was solved based o...
Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Towards a Nitinol-Based Microfabricated Approach to Repair Long-Gap Esophageal Atresia
Towards a Nitinol-Based Microfabricated Approach to Repair Long-Gap Esophageal Atresia
Long-gap esophageal atresia is a congenital anomaly that requires challenging repair procedures that are often associated with complications. This work proposes the use of nitinol ...
Design and Development of Nitinol Engine
Design and Development of Nitinol Engine
Nitinol, a nickel-titanium alloy, has become a focal point in energy conversion research due to its exceptional shape memory effect (SME) and superelasticity. These properties allo...
Navigating Anchor Relevance Skillfully: Expertise Reduces Susceptibility to Anchoring Effects
Navigating Anchor Relevance Skillfully: Expertise Reduces Susceptibility to Anchoring Effects
50 years ago Tversky and Kahneman (1974) described anchoring as the phenomenon whereby an irrelevant numerical value influences a subsequent numerical judgment. Although expertise ...
Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables
Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables
This study investigates the use of braided tubular superelastic cables, previously used for sternum closure following sternotomy, as sublaminar fixation method. It compares the bio...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract
Purpose
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
...

