Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of a Filtering Respirator with a Real-Time Monitoring Device for Pressure Drop

View through CrossRef
Purpose. Development of a filtering respirator with a device for operational pressure drop control. Method: The development of the filtering respirator with a real-time monitoring device for pressure drop involves the use of the following equipment: the ESP32-C6-LCD-1.47 microcontroller with a video display, and the MPXV7002DP FRS pressure sensor, which enable monitoring of the pressure drop caused by dust accumulation, based on determining the critical filter resistance value. Findings. A real-time monitoring device for pressure drop in the respirator filter box has been developed. It provides prerequisites for improving worker safety in hazardous conditions and extends the possibilities of personalizing respiratory protective equipment according to specific operational requirements and users’ physiological characteristics. The developed algorithm of the device enhances the protective properties of the filtering respirator by timely informing the user about the pressure drop status of the filter, which is associated with half-mask tightness and battery charge level. A mathematical model has been proposed, correlating filter parameters, breathing mode, and the characteristics of the pressure drop sensor, which allows for determining changes in the pressure drop across the filter element depending on dust accumulation on the filter surface. This makes it possible to control filter service life by comparing it with the critical pressure drop value. Paper type. Experimental studies of filtering respirator’ performance indicators.
Title: Development of a Filtering Respirator with a Real-Time Monitoring Device for Pressure Drop
Description:
Purpose.
Development of a filtering respirator with a device for operational pressure drop control.
Method: The development of the filtering respirator with a real-time monitoring device for pressure drop involves the use of the following equipment: the ESP32-C6-LCD-1.
47 microcontroller with a video display, and the MPXV7002DP FRS pressure sensor, which enable monitoring of the pressure drop caused by dust accumulation, based on determining the critical filter resistance value.
Findings.
A real-time monitoring device for pressure drop in the respirator filter box has been developed.
It provides prerequisites for improving worker safety in hazardous conditions and extends the possibilities of personalizing respiratory protective equipment according to specific operational requirements and users’ physiological characteristics.
The developed algorithm of the device enhances the protective properties of the filtering respirator by timely informing the user about the pressure drop status of the filter, which is associated with half-mask tightness and battery charge level.
A mathematical model has been proposed, correlating filter parameters, breathing mode, and the characteristics of the pressure drop sensor, which allows for determining changes in the pressure drop across the filter element depending on dust accumulation on the filter surface.
This makes it possible to control filter service life by comparing it with the critical pressure drop value.
Paper type.
Experimental studies of filtering respirator’ performance indicators.

Related Results

Adjusting a commonly used respirator pressure drop equation for use with modern respirators
Adjusting a commonly used respirator pressure drop equation for use with modern respirators
Millions of workers in the United States require the use of a respirator while at work. Occupational inhalation hazards have the potential to cause respiratory diseases. Wearing ...
Woningcorporaties en Vastgoedontwikkeling
Woningcorporaties en Vastgoedontwikkeling
This summary highlights the findings of the PhD-thesis ‘Woningcorporaties en Vastgoedontwikkeling: Fit for Use’ (‘Housing associations and Real Estate Development: Fit for Use?’). ...
Numerical Simulation on Steam-Water Separator Performance Based on Population Balance Model
Numerical Simulation on Steam-Water Separator Performance Based on Population Balance Model
The performance of the moisture separator is simulated and analyzed by the Euler two fluid model with population balance model (PBM), and compared with the traditional single drop ...
Filtering Methods for Biomedical Image Denoising
Filtering Methods for Biomedical Image Denoising
In this paper, the filtering method of biomedical image denoising is described comprehensively. Firstly, it introduces the biomedical image denoising, describes the relationship be...
Extensions of Pressure Build-Up Analysis Methods
Extensions of Pressure Build-Up Analysis Methods
RUSSELL, D.G.,* MEMBER AIME, SHELL DEVELOPMENT CO., HOUSTON, TEX. Abstract Two techniques have been developed with which the app...

Back to Top