Javascript must be enabled to continue!
Thermal Analysis of Blood Pump Rotor System
View through CrossRef
In order to study the heat conduction, convection and heat flux density of blood for blood pump rotor system,and established the three-dimensional model of the blood pump rotor system in Solidworks, and then will establish a model to lead the finite element analysis in ANSYS Workbench, thermal analysis, the result of analysis is temperature distribution and heat flux distribution and temperature deformation figure of the blood pump rotor system. Through the study, the rise of temperature of the blood pump rotor system meets the requirements, and The structure design is reasonable;the blood pump rotor system overall deformation is small,but it’s not affect the normal work of the blood pump, It could provided data to support the optimization design of the blood pump rotor system.
Trans Tech Publications, Ltd.
Title: Thermal Analysis of Blood Pump Rotor System
Description:
In order to study the heat conduction, convection and heat flux density of blood for blood pump rotor system,and established the three-dimensional model of the blood pump rotor system in Solidworks, and then will establish a model to lead the finite element analysis in ANSYS Workbench, thermal analysis, the result of analysis is temperature distribution and heat flux distribution and temperature deformation figure of the blood pump rotor system.
Through the study, the rise of temperature of the blood pump rotor system meets the requirements, and The structure design is reasonable;the blood pump rotor system overall deformation is small,but it’s not affect the normal work of the blood pump, It could provided data to support the optimization design of the blood pump rotor system.
Related Results
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Static Structural Analysis of the Blood Pump Rotor System
Static Structural Analysis of the Blood Pump Rotor System
In order to study the impact of external forces of the influence of the structural characteristics of axial flow blood pump rotor system.Using the blood pump rotor system as the re...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
PROTOTYPE POMPA APUNG
PROTOTYPE POMPA APUNG
ABSTRACT
Floating pump is a water pump than can flat and adapt to the level of water surface. This water pump is solution of the problem happens because of the significant increas...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract
The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements
NASA's Europa Clipper mission will characterize the current and recent surface activity of the icy-moon Europa through a wide range of remote sensing observations. In particular, t...
Cross-Sectional Study on Knowledge, Attitude and Practice of Voluntary Blood Donation among Nursing Staff at Orotta National Referral Teaching Hospital Asmara, Eritrea
Cross-Sectional Study on Knowledge, Attitude and Practice of Voluntary Blood Donation among Nursing Staff at Orotta National Referral Teaching Hospital Asmara, Eritrea
Introduction: Blood transfusion is one of the essential components of quality health care service package. Safe blood for transfusion is obtained mainly from Voluntary blood donors...
Modular Rotor Single Phase Field Excited Flux Switching Machine with Non-Overlapped Windings
Modular Rotor Single Phase Field Excited Flux Switching Machine with Non-Overlapped Windings
In recent years, numerous topologies of single phase and three phase Field Excited Flux-Switching Machine (FEFSM) have been developed for several applications. Comparative study of...