Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
View through CrossRef
Objectives: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome.
Patients and methods: The study included 83 patients (21 males, 62 females; mean age 51.6±11.0 years; range, 26 to 70 years) with shoulder impingement syndrome. The supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio values were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were calculated.
Results: The first observer had excellent intra-rater reliability in all measurements (ICC >0.90) with minimum detectable change of 0.740-0.047 mm and standard error of measurement of 0.017-0.26 mm. The second observer had excellent intra-rater reliability in supraspinatus tendon thickness and acromiohumeral distance measurements (ICC >0.90) with minimum detectable change of 0.498-0.770 mm and standard error of measurement of 0.18-0.28 mm and good intra-rater reliability in the occupation ratio measurement (ICC; 0.75-0.90) with minimum detectable change of 0.060 mm and standard error of measurement of 0.022 mm. Inter-rater reliability coefficients were 0.916 (95% confidence interval [CI]; 0.873-0.945) for supraspinatus tendon thickness, 0.943 (95% CI; 0.914-0.963) for acromiohumeral distance with minimum detectable change of 0.673 mm and standard error of measurement of 0.243 mm and 0.790 (%95 CI; 0.693-0.853) for occupation ratio with minimum detectable change of 0.077 mm and standard error of measurement of 0.028 mm.
Conclusion: These findings suggest that ultrasonographic measurements of the supraspinatus tendon thickness, acromiohumeral distance and occupation ratio can be reliable and consistent for clinical evaluation of patients with shoulder impingement syndrome in terms of supporting diagnosis and monitoring the treatment effect.
AVES YAYINCILIK A.Ş.
Title: Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
Description:
Objectives: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome.
Patients and methods: The study included 83 patients (21 males, 62 females; mean age 51.
6±11.
0 years; range, 26 to 70 years) with shoulder impingement syndrome.
The supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio values were obtained one week apart by two observers.
The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were calculated.
Results: The first observer had excellent intra-rater reliability in all measurements (ICC >0.
90) with minimum detectable change of 0.
740-0.
047 mm and standard error of measurement of 0.
017-0.
26 mm.
The second observer had excellent intra-rater reliability in supraspinatus tendon thickness and acromiohumeral distance measurements (ICC >0.
90) with minimum detectable change of 0.
498-0.
770 mm and standard error of measurement of 0.
18-0.
28 mm and good intra-rater reliability in the occupation ratio measurement (ICC; 0.
75-0.
90) with minimum detectable change of 0.
060 mm and standard error of measurement of 0.
022 mm.
Inter-rater reliability coefficients were 0.
916 (95% confidence interval [CI]; 0.
873-0.
945) for supraspinatus tendon thickness, 0.
943 (95% CI; 0.
914-0.
963) for acromiohumeral distance with minimum detectable change of 0.
673 mm and standard error of measurement of 0.
243 mm and 0.
790 (%95 CI; 0.
693-0.
853) for occupation ratio with minimum detectable change of 0.
077 mm and standard error of measurement of 0.
028 mm.
Conclusion: These findings suggest that ultrasonographic measurements of the supraspinatus tendon thickness, acromiohumeral distance and occupation ratio can be reliable and consistent for clinical evaluation of patients with shoulder impingement syndrome in terms of supporting diagnosis and monitoring the treatment effect.
Related Results
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Chronic non-traumatic shoulder pain: evaluation with ultrasonography and conventional mr imaging
Chronic non-traumatic shoulder pain: evaluation with ultrasonography and conventional mr imaging
Abstract
Background
Shoulder pain is a common and disabling complaint. It is responsible for approximately 16 % of all musculosk...
Frequency of supraspinatus tear and its association with reduced acromiohumeral interval using magnetic resonance imaging
Frequency of supraspinatus tear and its association with reduced acromiohumeral interval using magnetic resonance imaging
Background: Supraspinatus tendon tears are a common cause of chronic shoulder pain and functional limitation. An acromiohumeral interval (AHI) less than normal may be a useful radi...
Mineralization of the Supraspinatus Tendon: Clinical Observations in Seven Dogs
Mineralization of the Supraspinatus Tendon: Clinical Observations in Seven Dogs
Summary
Mineral-like densities in the supraspinatus tendon were determined to have different clinical significance according to their location. Those identified r...
Inter-Rater and Intra-Rater reliability of rehabilitative ultrasound imaging of core muscle thickness in individuals with Anterior Pelvic Tilt
Inter-Rater and Intra-Rater reliability of rehabilitative ultrasound imaging of core muscle thickness in individuals with Anterior Pelvic Tilt
Background & Objectives: Excessive lordotic curvature of the lumbar spine defines the phenomenon known as anterior pelvic tilt, which causes changes in posture, movement, and c...
Partial supraspinatus tears are associated with tendon lengthening
Partial supraspinatus tears are associated with tendon lengthening
AbstractPurposeTendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method ...
CHT/CFD Predictions of Impingement Cooling With Four Sided Flow Exit
CHT/CFD Predictions of Impingement Cooling With Four Sided Flow Exit
Impingement/effusion cooling has no cross-flow in the impingement gap if all the coolant flow through the impingement wall passes through the effusion wall. In this investigation, ...
Role of ultrasound elastography in the evaluation of rotator cuff tendon in patients with shoulder pain and its comparison with magnetic resonance imaging
Role of ultrasound elastography in the evaluation of rotator cuff tendon in patients with shoulder pain and its comparison with magnetic resonance imaging
Background: Pain in the shoulder is the third-most prevalent musculoskeletal pain type. Most frequently involved in tendinopathy/tendon tears is the supraspinatus tendon, followed ...