Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Reliability of electroencephalogram indicator and event related potential in subacute stroke

View through CrossRef
Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance. Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient compliance. Objective evaluation methods include electroencephalogram (EEG) and event-related potential (ERP). This study was conducted to assess intra-tester reliability of resting EEG-based spectral features and auditory/visual P300 latency/amplitude in patients with subacute ischemic stroke. Twenty patients with subacute ischemic stroke were included in the study. The resting EEG and P300 wave using an auditory and visual oddball paradigm were measured at baseline and once again in 24 hours. The following electrode positions (10–20 system) were constantly recorded: F3 (Frontal), Fz, F4, C3 (Central), Cz, C4, P3 (Parietal), Pz, P4. DAR (delta/alpha ratio) and BSI (brain symmetry index) were determined using EEG data. F3 and F4, C3 and C4 and P3 and P4 were switched according to the stroke side and classified as affected hemisphere (AH) and unaffected hemisphere (UH) after the evaluation. In ERP, the amplitude and latency of P300 were obtained. In reliability analysis of EEG-based spectral characteristics, significant reliability was observed for DAR (ICC = 0.447), BSldir (ICC = 0.713) and BSIdirtheta (ICC = 0.724) (Table 4). DAR was showed a poor ICC level, and BSIdir and BSIdirtheta had a moderate ICC level. Visual P300 latency showed excellent intraclass correlation coefficient (ICC) in several montages (PUH = 0.972, Pz = 0.945). In 6 montages, auditory P300 latency was reliable, while in 9 montages, visual P300 latency was reliable. In 4 montages, auditory P300 amplitude was reliable, while visual P300 amplitude was reliable in 7. The visual P300 was more reliable than the auditory P300. The ICC values for P300 latency were greater than those for amplitude. Therefore, when ERP is performed on subacute stroke patients, visual has higher reliability than auditory.
Title: Reliability of electroencephalogram indicator and event related potential in subacute stroke
Description:
Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance.
Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient compliance.
Objective evaluation methods include electroencephalogram (EEG) and event-related potential (ERP).
This study was conducted to assess intra-tester reliability of resting EEG-based spectral features and auditory/visual P300 latency/amplitude in patients with subacute ischemic stroke.
Twenty patients with subacute ischemic stroke were included in the study.
The resting EEG and P300 wave using an auditory and visual oddball paradigm were measured at baseline and once again in 24 hours.
The following electrode positions (10–20 system) were constantly recorded: F3 (Frontal), Fz, F4, C3 (Central), Cz, C4, P3 (Parietal), Pz, P4.
DAR (delta/alpha ratio) and BSI (brain symmetry index) were determined using EEG data.
F3 and F4, C3 and C4 and P3 and P4 were switched according to the stroke side and classified as affected hemisphere (AH) and unaffected hemisphere (UH) after the evaluation.
In ERP, the amplitude and latency of P300 were obtained.
In reliability analysis of EEG-based spectral characteristics, significant reliability was observed for DAR (ICC = 0.
447), BSldir (ICC = 0.
713) and BSIdirtheta (ICC = 0.
724) (Table 4).
DAR was showed a poor ICC level, and BSIdir and BSIdirtheta had a moderate ICC level.
Visual P300 latency showed excellent intraclass correlation coefficient (ICC) in several montages (PUH = 0.
972, Pz = 0.
945).
In 6 montages, auditory P300 latency was reliable, while in 9 montages, visual P300 latency was reliable.
In 4 montages, auditory P300 amplitude was reliable, while visual P300 amplitude was reliable in 7.
The visual P300 was more reliable than the auditory P300.
The ICC values for P300 latency were greater than those for amplitude.
Therefore, when ERP is performed on subacute stroke patients, visual has higher reliability than auditory.

Related Results

Iranian stroke model-how to involve health policymakers
Iranian stroke model-how to involve health policymakers
Stroke in Iran, with more than 83 million population, is a leading cause of disability and mortality in adults. Stroke has higher incidence in Iran comparing the global situation a...
Comparative Characterization of Candidate Molecular Markers in Ischemic and Hemorrhagic Stroke
Comparative Characterization of Candidate Molecular Markers in Ischemic and Hemorrhagic Stroke
According to epidemiological studies, the leading cause of morbidity, disability and mortality are cerebrovascular diseases, in particular ischemic and hemorrhagic strokes. In rece...
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
Hypertension, Age, Sex, and  Stroke  Incidence In Stroke Installation Room RSUD dr. M. Yunus BengkuluABSTRAKStroke adalah gejala-gejala defisit fungsi susunan saraf yang diakibatka...
Abstract 3387: Community Education: A Statewide Effort
Abstract 3387: Community Education: A Statewide Effort
Background: The fourth leading cause of death for all Iowans is stroke. Southeast Iowa has higher mortality rates from stroke than northeast Iowa which indicates a geog...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
Scoping Review of Existing Stroke Guidelines; Argument for a Value-Added Change
Scoping Review of Existing Stroke Guidelines; Argument for a Value-Added Change
Abstract Background and Purpose Stroke represents one of the most important causes of morbidity ( eighty million patients with ...
Systematic Review of Existing Stroke Guidelines: Case for a Change
Systematic Review of Existing Stroke Guidelines: Case for a Change
Background and Purpose. Stroke represents one of the most important causes of morbidity (Just over hundred million patients with disabling of ongoing effects of...
Heterogeneity among women with stroke: health, demographic and healthcare utilization differentials
Heterogeneity among women with stroke: health, demographic and healthcare utilization differentials
Abstract Background Although age specific stroke rates are higher in men, women have a higher lifetime risk and are more likely to die from a stroke...

Back to Top