Javascript must be enabled to continue!
Analysis of the reconstruction of load curves in an urban Low Voltage substation
View through CrossRef
The study of the load curves in an urban Low Voltage (LV) substation is a work that has been carried out over several years. A load curve is a sequence of values, associated with the energy consumption, in time. This sequence can be considered as a signal and, in order to study it the techniques and tools of signal processing can be applied. This article applies different signal processing tools to analyze the interpolation of the load curve of an urban LV substation. The above mentioned interpolation can be necessary for both the case of lost measurements reconstruction and for the estimation of non-existent measurements. The tests have been carried out on a records database of an actual LV substation. The power records have been made over more than 10 years. This substation has been selected because its consumptions were representative of the entire city, not only of the influence area. This choice has been made comparing LV substation measurements with the sum of the measurements of the high voltage lines that supply electricity to the city. The extracted conclusions are valid in trying to improve future predictive models of lost measurements reconstruction, data construction, etc.
UK Zhende Publishing Limited Company
Title: Analysis of the reconstruction of load curves in an urban Low Voltage substation
Description:
The study of the load curves in an urban Low Voltage (LV) substation is a work that has been carried out over several years.
A load curve is a sequence of values, associated with the energy consumption, in time.
This sequence can be considered as a signal and, in order to study it the techniques and tools of signal processing can be applied.
This article applies different signal processing tools to analyze the interpolation of the load curve of an urban LV substation.
The above mentioned interpolation can be necessary for both the case of lost measurements reconstruction and for the estimation of non-existent measurements.
The tests have been carried out on a records database of an actual LV substation.
The power records have been made over more than 10 years.
This substation has been selected because its consumptions were representative of the entire city, not only of the influence area.
This choice has been made comparing LV substation measurements with the sum of the measurements of the high voltage lines that supply electricity to the city.
The extracted conclusions are valid in trying to improve future predictive models of lost measurements reconstruction, data construction, etc.
Related Results
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract
History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
Life Cycle Cost Analysis and Optimization of Modular Substation
Life Cycle Cost Analysis and Optimization of Modular Substation
Due to the lack of high standardization and specialization, the production scale of modular substation is difficult to meet the established requirements. Compared with traditional ...
Analysis and Research on Lightning Inrush Wave Overvoltage in EHV GIS Substation transformation project
Analysis and Research on Lightning Inrush Wave Overvoltage in EHV GIS Substation transformation project
Abstract
When lightning intrudes into the over-voltage in the 500 kV substation, the lightning wave will be introduced into the substation along the line, which will...
Life Cycle Cost Prediction of Substation Based on Advanced PSO and Least Squares Support Vector Machine
Life Cycle Cost Prediction of Substation Based on Advanced PSO and Least Squares Support Vector Machine
Abstract
The rapid prediction of the full life cycle cost of substation has guiding significance for the construction of substation. In this paper, a substation full...
A research based on testing method for the whole substation cascaded in digital substation
A research based on testing method for the whole substation cascaded in digital substation
Substation as an important component of the power grid, its safe and steady operation is crucial to the power grid. After building new substation or renovating the old ones, they n...
Orthogonal Curve Analysis of Human Scalp Shape
Orthogonal Curve Analysis of Human Scalp Shape
This paper presents a shape analysis on orthogonal feature curves of 3D bald head scans with the intention of predicting scalp shape under the hair. While there are currently a num...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...