Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of methods for the separation and characterization of natural organic matter in dam water

View through CrossRef
This project arose out the need for a simple method to analyse NOM on a routine basis. Water samples were obtained from the Vaal dam, which is one of the dams used by a hydroelectric power station. Analysis was preceded by separation of NOM into the humic and non-humic portions. The humic portion was separated into two fractions by employing a non-ionic resin (DAX-8) to separate humic acid from fulvic acid. High performance size exclusion chromatography (HPSEC), equipped with an Ultraviolet( UV) detector and an Evaporative Light Scattering (ELS) detector connected in series, was used to obtain molecular weight distribution information and the concentration levels of the two acids. Mixed standards of polyethylene oxide/glycol were employed to calibrate the selected column. Suwanee River humic acid standard was used as a certified reference material. The molecular weight distributions (MWDs) of the isolated fractions of humic and fulvic acids were determined with ELSD detection as weight-average (Mw), number-average (Mn) and polydispersity (ρ) of individual NOM fractions. The Mw/Mn ratio was found to be less than 1.5 in all the fractions, indicating that they have a low and narrow size fraction. An increase in Mn and Mw values, with increasing wavelength for all three humic substances (HS) examined was observed. The HS, isolated from the dam water, was found to be about the same molecular weight as the International Humic Acid Standard (IIHSS). For the fulvic acid standard, the molecular weight was estimated to be around 7500 Da. Characterization of NOM was done to assist in the identification of the species present in the water. FTIR-ATR was used to as a characterization tool to identify the functional groups in the structure of the humic and fulvic acid respectively present in the Vaal Dam. Analysis of the infrared (IR) spectra indicated that the humic acids of the Vaal dam have phenolic hydroxyl groups, hydroxyl groups, conjugated double bond of aromatic family (C=C), and free carboxyl groups. The isolation method has proved to be applicable and reliable for dam water samples and showed to successfully separate the humic substances from water and further separate the humic substances into its hydrophobic acids, namely, humic and fulvic acids. It can be concluded that the Eskom Vaal dam composes of humic substance which shows that the technique alone gives a very good indication of the characteristics of water. The HPSEC method used, equipped with UV and ELSD was able to identify the molecular weight range of NOM present in source water as it confirmed that the Eskom Vaal dam contains humic substances as humic acid and fulvic acid and these pose a health concern as they can form disinfectant byproducts in the course of water treatment with chemicals. FTIR characterization was successful as important functional groups were clearly assigned. Lastly, the use of the TOC and DOC values to calculate SUVA was also a good tool to indicate the organic content in water. It is recommended to use larger amounts of water must be processed to obtain useful quantities of the humic and fulvic acid fractions.
Durban University of Technology
Title: Development of methods for the separation and characterization of natural organic matter in dam water
Description:
This project arose out the need for a simple method to analyse NOM on a routine basis.
Water samples were obtained from the Vaal dam, which is one of the dams used by a hydroelectric power station.
Analysis was preceded by separation of NOM into the humic and non-humic portions.
The humic portion was separated into two fractions by employing a non-ionic resin (DAX-8) to separate humic acid from fulvic acid.
High performance size exclusion chromatography (HPSEC), equipped with an Ultraviolet( UV) detector and an Evaporative Light Scattering (ELS) detector connected in series, was used to obtain molecular weight distribution information and the concentration levels of the two acids.
Mixed standards of polyethylene oxide/glycol were employed to calibrate the selected column.
Suwanee River humic acid standard was used as a certified reference material.
The molecular weight distributions (MWDs) of the isolated fractions of humic and fulvic acids were determined with ELSD detection as weight-average (Mw), number-average (Mn) and polydispersity (ρ) of individual NOM fractions.
The Mw/Mn ratio was found to be less than 1.
5 in all the fractions, indicating that they have a low and narrow size fraction.
An increase in Mn and Mw values, with increasing wavelength for all three humic substances (HS) examined was observed.
The HS, isolated from the dam water, was found to be about the same molecular weight as the International Humic Acid Standard (IIHSS).
For the fulvic acid standard, the molecular weight was estimated to be around 7500 Da.
Characterization of NOM was done to assist in the identification of the species present in the water.
FTIR-ATR was used to as a characterization tool to identify the functional groups in the structure of the humic and fulvic acid respectively present in the Vaal Dam.
Analysis of the infrared (IR) spectra indicated that the humic acids of the Vaal dam have phenolic hydroxyl groups, hydroxyl groups, conjugated double bond of aromatic family (C=C), and free carboxyl groups.
The isolation method has proved to be applicable and reliable for dam water samples and showed to successfully separate the humic substances from water and further separate the humic substances into its hydrophobic acids, namely, humic and fulvic acids.
It can be concluded that the Eskom Vaal dam composes of humic substance which shows that the technique alone gives a very good indication of the characteristics of water.
The HPSEC method used, equipped with UV and ELSD was able to identify the molecular weight range of NOM present in source water as it confirmed that the Eskom Vaal dam contains humic substances as humic acid and fulvic acid and these pose a health concern as they can form disinfectant byproducts in the course of water treatment with chemicals.
FTIR characterization was successful as important functional groups were clearly assigned.
Lastly, the use of the TOC and DOC values to calculate SUVA was also a good tool to indicate the organic content in water.
It is recommended to use larger amounts of water must be processed to obtain useful quantities of the humic and fulvic acid fractions.

Related Results

Application of AHP in flood combination calculation of check dam system
Application of AHP in flood combination calculation of check dam system
Check dam is an important water and soil conservation measure for comprehensive treatment of small watershed in the Loess Plateau. The reinforcement of sick and dangerous check dam...
Structure and Fractal Characteristics of Organic Matter Pores in Wufeng–Lower Longmaxi Formations in Southern Sichuan Basin, China
Structure and Fractal Characteristics of Organic Matter Pores in Wufeng–Lower Longmaxi Formations in Southern Sichuan Basin, China
Organic matter pores constitute a significant storage space in shale gas reservoirs, contributing to approximately 50% of the total porosity. This study employed a comprehensive ap...
Modal Analysis of Chushandian Gravity Dam
Modal Analysis of Chushandian Gravity Dam
This article uses the finite element software ABAQUS to establish a three-dimensional finite element model based on the overflow dam section 12 # ~15 # and surface outlet dam secti...
Physicochemical and oligotrophic status impact on Warwade dam water quality, Dutse, Jigawa State, Nigeria
Physicochemical and oligotrophic status impact on Warwade dam water quality, Dutse, Jigawa State, Nigeria
Warwade Dam, one of the biggest dams in Dutse land, is 1.4 km long, 6 m wide, 10 m deep, and has a total capacity of 300 million cubic meters of water. It is situated between latit...
Study on Deformation Characteristics of Gate Dam and Earth-Rock Dam System on Deep Overburden
Study on Deformation Characteristics of Gate Dam and Earth-Rock Dam System on Deep Overburden
The gate dam and earth-rock dam system offers advantages such as minimal ecological impact and strong terrain adaptability, making them the preferred dam type for low-head, high-fl...
Study on Deformation Characteristics of Gate Dam and Earth–Rock Dam Systems with Deep Overburden
Study on Deformation Characteristics of Gate Dam and Earth–Rock Dam Systems with Deep Overburden
Gate dam and earth–rock dam systems have many advantages, such as minimal ecological impact and good terrain adaptability, making them the preferred dam type for low-head, high-flo...
Exploring the influence of chemical extraction on the complexity of the Soluble Organic Matter (SOM) in carbonaceous chondrites
Exploring the influence of chemical extraction on the complexity of the Soluble Organic Matter (SOM) in carbonaceous chondrites
The complexity and origin of organic matter in carbonaceous chondrites has been a topic of interest for over 60 years1. This organic matter has been studied through the bulk, the I...

Back to Top