Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Bioaerosol in Composting Facilities: A Survey on Full-Scale Plants in Italy

View through CrossRef
Bioaerosols lead to human health diseases and composting plants are one of the main sources among human activities. In this study, a survey was conducted on such plants to evaluate bioaerosol risk management. A questionnaire was used to collect information on plant location, process types, collective and personal protective equipment, bioaerosol and particulate matter monitoring data, and occupational surveillance. We examined the data produced by 11 plants located in Italy. Self-control bioaerosol monitoring showed a global contamination index mean of 9908 CFU/m3 underlining a higher concentration (a) in plants with only aerobic process (CPs) with respect to plants that also combined anaerobic treatment of the waste (ADCPs) (p < 0.05) and (b) in facilities with biocells with respect to windrows (p < 0.01). Workers are generally more exposed when working without vehicles. Some areas such as pre-treatment and screening are more prone to higher bioaerosol concentrations, requiring more efficient collective protective equipment. Particulate matter monitoring showed concentration in line with occupational exposure limits for inhalable dust (1862 ± 1729 µg/m3) and breathable dust (276 ± 126 µg/m3), however, organic particle exposure risk assessment has to be carefully reviewed. Improvements in the training program, process design, and health surveillance are desirable as major preventive tools.
Title: Bioaerosol in Composting Facilities: A Survey on Full-Scale Plants in Italy
Description:
Bioaerosols lead to human health diseases and composting plants are one of the main sources among human activities.
In this study, a survey was conducted on such plants to evaluate bioaerosol risk management.
A questionnaire was used to collect information on plant location, process types, collective and personal protective equipment, bioaerosol and particulate matter monitoring data, and occupational surveillance.
We examined the data produced by 11 plants located in Italy.
Self-control bioaerosol monitoring showed a global contamination index mean of 9908 CFU/m3 underlining a higher concentration (a) in plants with only aerobic process (CPs) with respect to plants that also combined anaerobic treatment of the waste (ADCPs) (p < 0.
05) and (b) in facilities with biocells with respect to windrows (p < 0.
01).
Workers are generally more exposed when working without vehicles.
Some areas such as pre-treatment and screening are more prone to higher bioaerosol concentrations, requiring more efficient collective protective equipment.
Particulate matter monitoring showed concentration in line with occupational exposure limits for inhalable dust (1862 ± 1729 µg/m3) and breathable dust (276 ± 126 µg/m3), however, organic particle exposure risk assessment has to be carefully reviewed.
Improvements in the training program, process design, and health surveillance are desirable as major preventive tools.

Related Results

Microbiological indicators of bioaerosol in veterinary medicine clinics
Microbiological indicators of bioaerosol in veterinary medicine clinics
Exposure to bioaerosol from the premises of veterinary clinics poses a significant threat to the health of veterinary staff and patient animals. Because pathogens of airborne infec...
Biodegradable Waste Management in Georgia: Problems of the Composting System Introduction
Biodegradable Waste Management in Georgia: Problems of the Composting System Introduction
Biodegradable waste management and, in particular, the introduction and implementation of composting systems are among the major problems for Georgia. An increase in the volume of ...
Composting for Feedlot Manure Management and Soil Quality
Composting for Feedlot Manure Management and Soil Quality
Contemporary industrialized grain and livestock production is Characterized by efficient, large‐scale confined animal feedlot operations (CAFOs) and equally efficient and large‐sca...
Continuous Detection of Pathogenic Bioaerosol Using Antibody Labelled Magnetic Beads and Flow Cytometry
Continuous Detection of Pathogenic Bioaerosol Using Antibody Labelled Magnetic Beads and Flow Cytometry
Biogenic aerosols play a key role in various infectious diseases, like COVID-19 (virus) and Tuberculosis (bacteria). This fact makes detecting and characterizing bioaerosol, especi...
Comparative Characterization of Atmospheric Bioaerosols in the Yangtze River Delta and the Tibetan Plateau
Comparative Characterization of Atmospheric Bioaerosols in the Yangtze River Delta and the Tibetan Plateau
Bioaerosols are an important component of atmospheric particulate matter and include a wide range of biological materials such as bacteria, fungal spores, pollen, and biological fr...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Waste Management through Composting: Challenges and Potentials
Waste Management through Composting: Challenges and Potentials
Composting is the controlled conversion of degradable organic products and wastes into stable products with the aid of microorganisms. Composting is a long-used technology, though ...

Back to Top