Javascript must be enabled to continue!
Assessment of coronary artery stents by 16 slice computed tomography
View through CrossRef
Objective: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography.
Patients and methods: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 × 0.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/s). Two independent blinded reviewers analysed the MSCT.
Results: 143 patients had previous stenting (232 stents) and 190 (82%) of the 232 stents were detected. Intrastent lumen was interpretable in 126 (64%) of the detected stents. Lumen interpretability depended on stent diameter: for stent diameter > 3 mm, 81% of lumens were interpretable, as against 51% with ⩽ 3 mm stent diameter (p < 0.001). Restenosis detection likewise depended on stent diameter: with small stents (⩽ 3 mm), sensitivity and specificity of MSCT were 54% and 100%, respectively; positive and negative predictive values were 100% and 94%. For stents with > 3 mm diameter, corresponding values were 86%, 100%, 100%, and 99%.
Conclusion: 16 slice MSCT allows analysis of in-stent lumen in about half of all stented angioplasties. It performs better when stent diameter is more than 3 mm and may offer a non-invasive alternative to conventional coronary angiography for monitoring stented coronary arteries. Technical progress may improve interpretability and hence increase the yield of MSCT in this application.
Title: Assessment of coronary artery stents by 16 slice computed tomography
Description:
Objective: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography.
Patients and methods: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 × 0.
75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/s).
Two independent blinded reviewers analysed the MSCT.
Results: 143 patients had previous stenting (232 stents) and 190 (82%) of the 232 stents were detected.
Intrastent lumen was interpretable in 126 (64%) of the detected stents.
Lumen interpretability depended on stent diameter: for stent diameter > 3 mm, 81% of lumens were interpretable, as against 51% with ⩽ 3 mm stent diameter (p < 0.
001).
Restenosis detection likewise depended on stent diameter: with small stents (⩽ 3 mm), sensitivity and specificity of MSCT were 54% and 100%, respectively; positive and negative predictive values were 100% and 94%.
For stents with > 3 mm diameter, corresponding values were 86%, 100%, 100%, and 99%.
Conclusion: 16 slice MSCT allows analysis of in-stent lumen in about half of all stented angioplasties.
It performs better when stent diameter is more than 3 mm and may offer a non-invasive alternative to conventional coronary angiography for monitoring stented coronary arteries.
Technical progress may improve interpretability and hence increase the yield of MSCT in this application.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
3D-printed polymeric bioresorbable stents for cardiovascular applications
3D-printed polymeric bioresorbable stents for cardiovascular applications
(English) Bioresorbable stents (BRS) have been envisioned as a revolution in the treatment of coronary heart disease. Ideally, stents would initially retain sufficient radial stren...
A study on risk factors of coronary artery disease in Chong Qing city
A study on risk factors of coronary artery disease in Chong Qing city
Objective
To investigate the relationship between risk factors and coronary artery disease in Chong Qing city, and to provide scientific basis for preventing and ...
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitat...
Computed Tomography-derived Fractional Flow Reserve: Clinical Review for Cardiologist
Computed Tomography-derived Fractional Flow Reserve: Clinical Review for Cardiologist
Abstract
Coronary artery disease remained a major global health burden, and although coronary computed tomography angiography provided detailed anatomical informa...
Evolving Paradigms in the Endovascular Treatment of Coronary Artery Disease [CAD]
Evolving Paradigms in the Endovascular Treatment of Coronary Artery Disease [CAD]
Background: Endovascular treatment, or more simply and more practically speaking, the technical implementation of stents [or stent grafts, coils, plugs, etc.] into the blood vessel...

