Javascript must be enabled to continue!
Radionuclide Diagnosis of Sentinel Lymph Nodes in Breast cancer with a Radiopharmaceutical Based on Technetium-99m Labeled Gamma Aluminum Oxide
View through CrossRef
Аim: To analyze the results of radionuclide diagnostics of sentinel lymph nodes (SLN) in patients with breast cancer (BC) with the radiotracer Sentiscan, 99mTc (manufacturer “MedicorPharma-Ural”) using the multimodal SPECT/CT at the stage of visualization. Material and methods: The study was retrospective, it included 48 patients with BC with clinical stage T2-3N0M0, who underwent radionuclide diagnostics of SLN and SPECT/CT was performed at the imaging stage. The images were evaluated visually, the intensity of the radiotracer accumulation in the lymph nodes (LN) was analyzed, SUVmax was used as a quantitative parameter. Intraoperative detection of SLN with subsequent histological examination was also carried out with the calculation of the level of the radiotracer accumulation. Results: On tomoscintigrams, LNs were visualized in 43 patients out of 48, intraoperatively ‒ in 46 cases, in 2 patients, accumulation of the radiotracer in the LN projection was noted neither according to SPECT/CT, nor intraoperatively. When analyzing the intensity of the radiotracer accumulation according to SPECT/CT data, a rather large scatter of SUVmax‒35 [10‒104]. Sentinel were considered LNs with the level of the radiotracer accumulation in them of at least 10 % of the most intense node. According to SPECT/CT data, 165 lymph nodes were identified, the average number of lymph nodes detected in one patient was 2 [1‒3], the maximum number was 6 lymph nodes. In all patients, the lymph nodes were determined in the projection of the 1st level, in 25 cases ‒ in the projection of other zones of regional lymphatic outflow. The total number of lymph nodes removed during surgery was n=247, on average 3 [2‒5] lymph nodes were removed in one patient, with a maximum of 8 nodes. Conclusion: The sensitivity of radionuclide diagnostics of SLN with Sentiscan, 99mTc was 89.6 % according to SPECT/CT and 95.8 % according to the results of intraoperative detection. The use of multimodal imaging provides information on the exact anatomical localization of the lymph nodes. In the absence of scintigraphic visualization of the radiotracer redistribution in the lymphatic collector, intraoperative detection does not lose its relevance.
Burnasyan Federal Medical Biophysical Center Of Federal Medical Biological Agency
Title: Radionuclide Diagnosis of Sentinel Lymph Nodes in Breast cancer with a Radiopharmaceutical Based on Technetium-99m Labeled Gamma Aluminum Oxide
Description:
Аim: To analyze the results of radionuclide diagnostics of sentinel lymph nodes (SLN) in patients with breast cancer (BC) with the radiotracer Sentiscan, 99mTc (manufacturer “MedicorPharma-Ural”) using the multimodal SPECT/CT at the stage of visualization.
Material and methods: The study was retrospective, it included 48 patients with BC with clinical stage T2-3N0M0, who underwent radionuclide diagnostics of SLN and SPECT/CT was performed at the imaging stage.
The images were evaluated visually, the intensity of the radiotracer accumulation in the lymph nodes (LN) was analyzed, SUVmax was used as a quantitative parameter.
Intraoperative detection of SLN with subsequent histological examination was also carried out with the calculation of the level of the radiotracer accumulation.
Results: On tomoscintigrams, LNs were visualized in 43 patients out of 48, intraoperatively ‒ in 46 cases, in 2 patients, accumulation of the radiotracer in the LN projection was noted neither according to SPECT/CT, nor intraoperatively.
When analyzing the intensity of the radiotracer accumulation according to SPECT/CT data, a rather large scatter of SUVmax‒35 [10‒104].
Sentinel were considered LNs with the level of the radiotracer accumulation in them of at least 10 % of the most intense node.
According to SPECT/CT data, 165 lymph nodes were identified, the average number of lymph nodes detected in one patient was 2 [1‒3], the maximum number was 6 lymph nodes.
In all patients, the lymph nodes were determined in the projection of the 1st level, in 25 cases ‒ in the projection of other zones of regional lymphatic outflow.
The total number of lymph nodes removed during surgery was n=247, on average 3 [2‒5] lymph nodes were removed in one patient, with a maximum of 8 nodes.
Conclusion: The sensitivity of radionuclide diagnostics of SLN with Sentiscan, 99mTc was 89.
6 % according to SPECT/CT and 95.
8 % according to the results of intraoperative detection.
The use of multimodal imaging provides information on the exact anatomical localization of the lymph nodes.
In the absence of scintigraphic visualization of the radiotracer redistribution in the lymphatic collector, intraoperative detection does not lose its relevance.
Related Results
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Coexisting Granulomatous Mastitis and Breast Cancer: A Systematic Review
Coexisting Granulomatous Mastitis and Breast Cancer: A Systematic Review
Abstract
Introduction: Granulomatous mastitis (GM) is a rare inflammatory breast disease that mimics carcinoma. GM can coexist with breast cancer (BC), though the relationship rema...
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Abstract
Introduction
Fine-needle aspiration (FNA) is commonly used to investigate lymphadenopathy of suspected metastatic origin. The current study aims to find the association be...
PENENTUAN KEMURNIAN RADIONUKLIDA DARI PRODUK GENERATOR Mo-99/Tc-99m NON-FISI MENGGUNAKAN SPEKTROMETER GAMMA
PENENTUAN KEMURNIAN RADIONUKLIDA DARI PRODUK GENERATOR Mo-99/Tc-99m NON-FISI MENGGUNAKAN SPEKTROMETER GAMMA
The medical radionuclide technetium-99m (Tc-99m) is the type of radionuclide that is most widely used in diagnostic processes in the world of nuclear medicine. This is related to i...
Systemic Sentinel Lymph Node Detection Using Fluorescence Imaging After Indocyanine Green Intravenous Injection in Colorectal Cancer: Protocol for a Feasibility Study (Preprint)
Systemic Sentinel Lymph Node Detection Using Fluorescence Imaging After Indocyanine Green Intravenous Injection in Colorectal Cancer: Protocol for a Feasibility Study (Preprint)
BACKGROUND
Nodal staging is a major concern in colorectal cancer as it is an important prognostic factor. Several techniques that could potentially improve ...
The effect of miRNAs and MALAT1 related with the prognosis of Her-2 positive breast cancer patients with lymph node metastasis
The effect of miRNAs and MALAT1 related with the prognosis of Her-2 positive breast cancer patients with lymph node metastasis
Abstract
Background: To analyze and screen the miRNAs associated with lymph node metastasis of breast cancer (BC), and to explore the roles of these miRNAs in the prolifera...
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...

