Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

METHODS OF STERILIZATION OF MEDICAL POLYMER COMPOSITES BASED ON POLYHYDROXYBUTYRATE WITH ELASTOMERIC ADDITIVE

View through CrossRef
Introduction. Polyhydroxybutyrate is a biodegradable and completely biocompatible component, and in combination with various modifying additives can be suitable for the manufacture of medical products used in surgical practice as bone implants or their parts. There implants have a number of advantages over traditional metal products, but for their integration into the body they require thorough sterilization cleaning, which in the case of poly-mer compositions has a number of limitations associated with the possible destruction of the material structure during various cleaning stages. Purpose of the study. Find optimal methods for sterilization and disinfection of materials based on polyhydroxybutyrate (PHB) and an elastomeric additive – butadiene-nitrile rubber (NBR-28). Material and methods. Two-component PHB-NBR compositions with PHB content from 30 to 90% were studied. Four methods of sterilization and disinfection were used: autoclaving, air sterilization, disinfection with chlorine solution and ethanol solution. Determined mechanical characteristics are strength and elongation of the material at break. Sterility control – by the method of washings with subsequent observation of the growth of bacteria and fungi in Sabouraud's medium and thioglycollate medium. Results. Sterilized and disinfected samples showed no microbial growth in both culture media. No change in mechanical characteristics was detected for samples subjected to solution cleaning methods. High temperature cleaning reduced the mechanical properties of samples by 20–80% depending on the sterilization mode. Conclusions. The data obtained show that for sterilization and disinfection of PCM based on the biodegradable polymer PHB, solution methods are suitable without restrictions and the autoclave sterilization method is suitable with minor restrictions, while air sterilization leads to the destruction of PCM. The work was financially supported by the Ministry of Science and Higher Education of Russian Federation (Research theme state registration number 122041300207-2).
Title: METHODS OF STERILIZATION OF MEDICAL POLYMER COMPOSITES BASED ON POLYHYDROXYBUTYRATE WITH ELASTOMERIC ADDITIVE
Description:
Introduction.
Polyhydroxybutyrate is a biodegradable and completely biocompatible component, and in combination with various modifying additives can be suitable for the manufacture of medical products used in surgical practice as bone implants or their parts.
There implants have a number of advantages over traditional metal products, but for their integration into the body they require thorough sterilization cleaning, which in the case of poly-mer compositions has a number of limitations associated with the possible destruction of the material structure during various cleaning stages.
Purpose of the study.
Find optimal methods for sterilization and disinfection of materials based on polyhydroxybutyrate (PHB) and an elastomeric additive – butadiene-nitrile rubber (NBR-28).
Material and methods.
Two-component PHB-NBR compositions with PHB content from 30 to 90% were studied.
Four methods of sterilization and disinfection were used: autoclaving, air sterilization, disinfection with chlorine solution and ethanol solution.
Determined mechanical characteristics are strength and elongation of the material at break.
Sterility control – by the method of washings with subsequent observation of the growth of bacteria and fungi in Sabouraud's medium and thioglycollate medium.
Results.
Sterilized and disinfected samples showed no microbial growth in both culture media.
No change in mechanical characteristics was detected for samples subjected to solution cleaning methods.
High temperature cleaning reduced the mechanical properties of samples by 20–80% depending on the sterilization mode.
Conclusions.
The data obtained show that for sterilization and disinfection of PCM based on the biodegradable polymer PHB, solution methods are suitable without restrictions and the autoclave sterilization method is suitable with minor restrictions, while air sterilization leads to the destruction of PCM.
The work was financially supported by the Ministry of Science and Higher Education of Russian Federation (Research theme state registration number 122041300207-2).

Related Results

Forced Sterilization
Forced Sterilization
Photo by Renè Müller on Unsplash INTRODUCTION Forced sterilization of women around the globe is a human rights violation and bioethical concern. In the past, countries enacted laws...
Pregnancy after Tubal Sterilization
Pregnancy after Tubal Sterilization
Objectives: In our study, we have tried to evaluate the causative factors for sterilization failure and also to discuss preventive measures to avoid maternal morbidities and unwant...
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
Sterilization is a critical process with wide-ranging applications in healthcare, pharmaceuticals, food production, and laboratory research. Its primary objective is the complete e...
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE: To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization. METHODS: This retrospe...
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE: To compare rates of gynecologic morbidity after laparoscopic and hysteroscopic sterilization. METHODS: This ret...
Nanogold and nanosilver hybrid polymer materials
Nanogold and nanosilver hybrid polymer materials
<p>Significant opportunities exist in both the scientific and industrial sectors for the development of new generation hybrid materials. These multifunctional hybrid material...
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Suture-Induced Tubo-Ovarian Abscess: A Case Report with Literature Review
Abstract Introduction Suture is an underreported cause for tubo-ovarian abscess (TOA) that can cause significant morbidity. This report describes a case of TOA arising from a silk ...
Biocompatibility of gelatins A and B after sterilization by different methods
Biocompatibility of gelatins A and B after sterilization by different methods
Introduction: The reliable sterilization of gelatin-based hydrogels is of critical importance for the clinical application of a multitude of biomanufactured functional constructs f...

Back to Top