Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

APPLICATION OF SELECTIVE HYPROMELLOSE SORBENT FOR THE BENZOCAINE QUANTITATION IN PHARMACEUTICAL FORMULATIONS

View through CrossRef
Introduction. In quality control of pharmaceutical formulations, there are methodological approaches based on the preliminary separation of sample components and approaches without preliminary separation. The use of solid-phase extraction (SPE) allows to separate analytes during sample prepa-ration, with the separation selectivity determining the analysis selectivity as a whole. Currently, sorbents that provide selectivity in interaction with the analyte are of interest. Aim. Evaluation of the metrological characteristics of benzocaine quantitation by UV-spectrophotometry in certain pharmaceutical formulations using hypromellose sorbent for solid-phase extraction. Material and methods. The sorbent using a method developed by us was obtained. Benzocaine (FS.2.1.0634, Russia State Pharmacopoeia XV ed.) to form active binding sites in sorbent structure was applied. The sorbent structure is polycyanoacrylate matrix with hypromellose fragments, the sur-face area is 255.50 m2/g, pore volume is 0.1433 cm3, pore diameter is 5.32 nm. The sorption capacity of hypromellose sorbent for benzocaine was 12.2±0.8 μg/g. The SPE technique is proposed. SPE includes the stages: conditioning, sample addition and step-by-step elution with purified water and hydrochloric acid solution 0.1 mol/L. The spectrophotometer SF-56 was used to measure the absorbance at an analytical wavelength of 286 nm. To evaluate the selectivity (specificity) of sample preparation during chromatographic (SPE) separation of pharmaceutical formulations, absorption spectra of eluates in the wavelength range of 200400 nm were scanned. The benzocaine identification in the eluate was carried out based on absorption peaks at 220 and 286 nm. The benzocaine calibration curve in the range of 120 μg/ml. To determination the metrological characteristics of benzocaine quan-titation method, 11 parallel determinations of samples of each pharmaceutical formulation were made. Results. When realizing the benzocaine quantitation technique for measuring absorbance, it is advisable to use only the first portions of eluate (a solu-tion of hydrochloric acid) in a volume of 510 ml were obtained. The relative error of benzocaine average concentration in the pharmaceutical formula-tions ranged from 1.28 to 1.34% for technique that included the SPE stage, and from 1.86 to 2.02% for technique that did not include it. A comparison of the modifications of the spectrophotometric quantitation of benzocaine in pharmaceutical formulation using hypromellose sorbent and technique without the SPE did not reveal a statistically significant difference in reproducibility. For the modification technique without SPE, an increase of benzo-caine concentration and in determination relative error by an average of 48.0% were observed. Conclusion. The possibility of using a selective hypromellose sorbent for sample preparation for benzocaine quantitation determination in pharmaceu-tical formulations has been showed. The use of a sorbent for SPE at the sample preparation stage reduces the systematic error of benzocaine spectro-photometry quantitation for the analyzed pharmaceutical formulations by an average of 79.2%.
Title: APPLICATION OF SELECTIVE HYPROMELLOSE SORBENT FOR THE BENZOCAINE QUANTITATION IN PHARMACEUTICAL FORMULATIONS
Description:
Introduction.
In quality control of pharmaceutical formulations, there are methodological approaches based on the preliminary separation of sample components and approaches without preliminary separation.
The use of solid-phase extraction (SPE) allows to separate analytes during sample prepa-ration, with the separation selectivity determining the analysis selectivity as a whole.
Currently, sorbents that provide selectivity in interaction with the analyte are of interest.
Aim.
Evaluation of the metrological characteristics of benzocaine quantitation by UV-spectrophotometry in certain pharmaceutical formulations using hypromellose sorbent for solid-phase extraction.
Material and methods.
The sorbent using a method developed by us was obtained.
Benzocaine (FS.
2.
1.
0634, Russia State Pharmacopoeia XV ed.
) to form active binding sites in sorbent structure was applied.
The sorbent structure is polycyanoacrylate matrix with hypromellose fragments, the sur-face area is 255.
50 m2/g, pore volume is 0.
1433 cm3, pore diameter is 5.
32 nm.
The sorption capacity of hypromellose sorbent for benzocaine was 12.
2±0.
8 μg/g.
The SPE technique is proposed.
SPE includes the stages: conditioning, sample addition and step-by-step elution with purified water and hydrochloric acid solution 0.
1 mol/L.
The spectrophotometer SF-56 was used to measure the absorbance at an analytical wavelength of 286 nm.
To evaluate the selectivity (specificity) of sample preparation during chromatographic (SPE) separation of pharmaceutical formulations, absorption spectra of eluates in the wavelength range of 200400 nm were scanned.
The benzocaine identification in the eluate was carried out based on absorption peaks at 220 and 286 nm.
The benzocaine calibration curve in the range of 120 μg/ml.
To determination the metrological characteristics of benzocaine quan-titation method, 11 parallel determinations of samples of each pharmaceutical formulation were made.
Results.
When realizing the benzocaine quantitation technique for measuring absorbance, it is advisable to use only the first portions of eluate (a solu-tion of hydrochloric acid) in a volume of 510 ml were obtained.
The relative error of benzocaine average concentration in the pharmaceutical formula-tions ranged from 1.
28 to 1.
34% for technique that included the SPE stage, and from 1.
86 to 2.
02% for technique that did not include it.
A comparison of the modifications of the spectrophotometric quantitation of benzocaine in pharmaceutical formulation using hypromellose sorbent and technique without the SPE did not reveal a statistically significant difference in reproducibility.
For the modification technique without SPE, an increase of benzo-caine concentration and in determination relative error by an average of 48.
0% were observed.
Conclusion.
The possibility of using a selective hypromellose sorbent for sample preparation for benzocaine quantitation determination in pharmaceu-tical formulations has been showed.
The use of a sorbent for SPE at the sample preparation stage reduces the systematic error of benzocaine spectro-photometry quantitation for the analyzed pharmaceutical formulations by an average of 79.
2%.

Related Results

PENJERAPAN GAS CO HASIL PEMBAKARAN SAMPAH MENGGUNAKAN SORBENT TERMODIFIKASI DALAM REAKTOR FIXED BED
PENJERAPAN GAS CO HASIL PEMBAKARAN SAMPAH MENGGUNAKAN SORBENT TERMODIFIKASI DALAM REAKTOR FIXED BED
ADSORPTION OF CO FROM WASTE COMBUSTION USING MODIFIED SORBENT IN A FIXED BED REACTOR. Gases produced by garbage burning consist of dangerous gases such as CO, SO2 and other gases. ...
Perianal Allergic Contact Dermatitis from Benzocaine – a Case Report
Perianal Allergic Contact Dermatitis from Benzocaine – a Case Report
Abstract A large number of contact allergic reactions to benzocaine have been reported since its introduction to the pharmaceutical market as an active ingredient...
Sorbent Membranes: Device Designs, Evaluations and Potential Applications
Sorbent Membranes: Device Designs, Evaluations and Potential Applications
ABSTRACTFor the biomedical application of sorbents in extracorporeal circulation, the system must be free of particle release and must be biocompatible. In addition, because of the...
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
BACKGROUND As of July 2020, a Web of Science search of “machine learning (ML)” nested within the search of “pharmacokinetics or pharmacodynamics” yielded over 100...
Cyanosis in the Pre-op Area
Cyanosis in the Pre-op Area
Abstract Case Presentation Pulmonology was consulted for a patient who developed acute hypoxic respiratory failure in the pre-op area. A 47-year-old female presen...
Synthesis and Characterization of Alginate Encapsulated Zirconium-Based Ferromagnetic Sorbent for Adsorptive Removal of Dyes
Synthesis and Characterization of Alginate Encapsulated Zirconium-Based Ferromagnetic Sorbent for Adsorptive Removal of Dyes
This paper provides insight on the removal of dyes from water using magnetic separation technique. A new alginate encapsulated zirconium-based encapsulated ferromagnetic sorbent ha...
Sintering Resistant Co2 Sorbents Prepared by Eggshell Derived Xerogels
Sintering Resistant Co2 Sorbents Prepared by Eggshell Derived Xerogels
A modified sol-gel like was used to prepare CaO sorbents from eggshells and carboxylic acids with improved sintering resistance. Sorbent materials obtained by calcination (900 °C) ...

Back to Top