Javascript must be enabled to continue!
Digital Impedance Emulator for Battery Measurement System Calibration
View through CrossRef
Meaningful information on the internal state of a battery can be derived by measuring its impedance. Accordingly, battery management systems based on electrochemical impedance spectroscopy are now recognized as a feasible solutions for online battery control and diagnostic. Since the impedance of a battery is always changing along with its state of charge and aging effects, it is important to have a stable impedance reference in order to calibrate and test a battery management system. In this work we propose a programmable impedance emulator that in principle could be used for the calibration of any battery management system based on electrochemical impedance spectroscopy. A digital finite-impulse-response filter is implemented, whose frequency response is programmed so as to reproduce exactly the impedance of a real battery in the frequency domain. The whole design process of the filter is presented in detail. An analytical expression for the impedance of real battery in the frequency domain is derived from an equivalent circuit model. The model is validated both through numerical simulations and experimental tests. In particular, the filter is implemented on a low-cost microcontroller unit, and the emulated impedance is measured by means of a custom-made electrochemical impedance spectroscopy measuring system, and verified by using standard commercial bench instruments. Results on this prototype show the feasibility of using the proposed emulator as a fully controllable and low-cost reference for calibrating battery impedance measurement systems.
Title: Digital Impedance Emulator for Battery Measurement System Calibration
Description:
Meaningful information on the internal state of a battery can be derived by measuring its impedance.
Accordingly, battery management systems based on electrochemical impedance spectroscopy are now recognized as a feasible solutions for online battery control and diagnostic.
Since the impedance of a battery is always changing along with its state of charge and aging effects, it is important to have a stable impedance reference in order to calibrate and test a battery management system.
In this work we propose a programmable impedance emulator that in principle could be used for the calibration of any battery management system based on electrochemical impedance spectroscopy.
A digital finite-impulse-response filter is implemented, whose frequency response is programmed so as to reproduce exactly the impedance of a real battery in the frequency domain.
The whole design process of the filter is presented in detail.
An analytical expression for the impedance of real battery in the frequency domain is derived from an equivalent circuit model.
The model is validated both through numerical simulations and experimental tests.
In particular, the filter is implemented on a low-cost microcontroller unit, and the emulated impedance is measured by means of a custom-made electrochemical impedance spectroscopy measuring system, and verified by using standard commercial bench instruments.
Results on this prototype show the feasibility of using the proposed emulator as a fully controllable and low-cost reference for calibrating battery impedance measurement systems.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Development of an Antenna Emulator Device for the JuventasRadar Experiment on the HERA Mission
Development of an Antenna Emulator Device for the JuventasRadar Experiment on the HERA Mission
The Juventas Radar (JuRa), a monostatic radar system designed to probe Didymos binarysystem internal structure using a BPSK coded signal. A key component in ensuring the effectiveo...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Access Denied
Access Denied
Introduction
As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Data-Driven Decision Making in Battery Technology – How to Compete in Global Battery Industry?
Data-Driven Decision Making in Battery Technology – How to Compete in Global Battery Industry?
Battery technology is regarded as a crucial key technology for the energy transition and thus a sustainable future, as batteries can store and distribute renewable energy to cover ...
Fast sensitivity analysis methods for computationally expensive models with multidimensional
output
Fast sensitivity analysis methods for computationally expensive models with multidimensional
output
Abstract. Global sensitivity analysis (GSA) is a critical approach in identifying which inputs or parameters of a model most affect model output. This determines which inputs to in...
APPLICATION OF SOLAR ENERGY TO MEASURE PHOTOVOLTAIC CAPACITY AND BATTERY OPTIMIZATION
APPLICATION OF SOLAR ENERGY TO MEASURE PHOTOVOLTAIC CAPACITY AND BATTERY OPTIMIZATION
This study uses the Markov Decision Model (MDP) to implement battery degradation and optimize battery use in Photovoltaic and the battery system model created. The battery optimiza...
Wireless Battery Management System with Data-Driven Modelling
Wireless Battery Management System with Data-Driven Modelling
In today's world, because of the universal use of batteries for different applications like electric vehicles, tools/appliances, and industrial equipment, battery monitori...

