Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

NOVEL NOVEL STABILITY-INDICATING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY METHOD FOR SIMULTANEOUS ESTIMATION OF HYDROCORTISONE AND TETRACYCLINE IN BULK AND PHARMACEUTICAL DOSAGE FORM

View through CrossRef
Objective: A combination of hydrocortisone and tetracycline as topical ophthalmic ointment is used for skin irritations, eye infections, inflammation, skin infections, acne, and rashes. The objective of the current work is to a simple, rapid, accurate, and precise, stability-indicating reverse-phase liquid chromatographic method was developed for the simultaneous estimation of hydrocortisone and tetracycline in bulk and pharmaceutical dosage form. Methods: The separation was carried out in Discovery C18 column (250 × 4.6 mm, 5 μm) using mobile phase ratio of water (pH 2.2 adjusted with orthophosphoric acid):acetonitrile (40:60 v/v) in an isocratic elution mode with a flow rate of 1.0 ml/min at detection wavelength of 244 nm. The injection volume was 10 μl and the column temperature was set at 30°C. Results: The retention time for hydrocortisone and tetracycline was found to be 2.214 ± 0.001 min and 3.497 ± 0.001 min, respectively. Calibration curves were linear (r2=0.999) at a concentration range of 2.5–15 mg/ml for both hydrocortisone and tetracycline. The percentage recoveries were found to be 99.13–99.67% for hydrocortisone and 99.39–99.61% for tetracycline. Relative standard deviation was found to be 0.3% for both the drugs. Limit of detection and limit of quantification values of hydrocortisone and tetracycline were found to be 0.09 μg/ml and 0.27 μg/ml and 0.17 μg/ml and 0.52 μg/ml, respectively. The drugs were subjected to various stress conditions and found no interference of degraded products peak at the retention times of analyte peaks. Conclusion: A rapid and accurate reverse-phase high-performance liquid chromatographic method was developed for simultaneous estimation of hydrocortisone and tetracycline, and the method was validated as per the International Council for Harmonization guidelines. Hence, the developed method can be successfully applied for the simultaneous estimation of hydrocortisone and tetracycline in bulk and ointment formulation.
Title: NOVEL NOVEL STABILITY-INDICATING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY METHOD FOR SIMULTANEOUS ESTIMATION OF HYDROCORTISONE AND TETRACYCLINE IN BULK AND PHARMACEUTICAL DOSAGE FORM
Description:
Objective: A combination of hydrocortisone and tetracycline as topical ophthalmic ointment is used for skin irritations, eye infections, inflammation, skin infections, acne, and rashes.
The objective of the current work is to a simple, rapid, accurate, and precise, stability-indicating reverse-phase liquid chromatographic method was developed for the simultaneous estimation of hydrocortisone and tetracycline in bulk and pharmaceutical dosage form.
Methods: The separation was carried out in Discovery C18 column (250 × 4.
6 mm, 5 μm) using mobile phase ratio of water (pH 2.
2 adjusted with orthophosphoric acid):acetonitrile (40:60 v/v) in an isocratic elution mode with a flow rate of 1.
0 ml/min at detection wavelength of 244 nm.
The injection volume was 10 μl and the column temperature was set at 30°C.
Results: The retention time for hydrocortisone and tetracycline was found to be 2.
214 ± 0.
001 min and 3.
497 ± 0.
001 min, respectively.
Calibration curves were linear (r2=0.
999) at a concentration range of 2.
5–15 mg/ml for both hydrocortisone and tetracycline.
The percentage recoveries were found to be 99.
13–99.
67% for hydrocortisone and 99.
39–99.
61% for tetracycline.
Relative standard deviation was found to be 0.
3% for both the drugs.
Limit of detection and limit of quantification values of hydrocortisone and tetracycline were found to be 0.
09 μg/ml and 0.
27 μg/ml and 0.
17 μg/ml and 0.
52 μg/ml, respectively.
The drugs were subjected to various stress conditions and found no interference of degraded products peak at the retention times of analyte peaks.
Conclusion: A rapid and accurate reverse-phase high-performance liquid chromatographic method was developed for simultaneous estimation of hydrocortisone and tetracycline, and the method was validated as per the International Council for Harmonization guidelines.
Hence, the developed method can be successfully applied for the simultaneous estimation of hydrocortisone and tetracycline in bulk and ointment formulation.

Related Results

7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see Rapid Communications in Mass Spectrometry 2012, 26 , ...
Kinetics of hydrocortisone sodium phosphate penetration into the human aqueous humor after topical application
Kinetics of hydrocortisone sodium phosphate penetration into the human aqueous humor after topical application
Aim of the study: Hydrocortisone is a soft steroid with low anti-inflammatory properties and a short duration of action, used to manage several ocular conditions. The clinical bene...
Topical Hydrocortisone Use in the Outpatient Department
Topical Hydrocortisone Use in the Outpatient Department
Aim: This study aimed to describe the use of topical hydrocortisone in the outpatient department in Alkharj. Methodology: This was a retrospective study that included reviewi...
Comparing Vasopressin and Hydrocortisone as Adjunctive Measures in Septic Shock
Comparing Vasopressin and Hydrocortisone as Adjunctive Measures in Septic Shock
Background: Norepinephrine has been widely established as the first-line agent for hemodynamic support in septic shock. The timing and order of initiation of va...
Development and validation of stability indicating chromatographic methods for simultaneous determination of citicoline and piracetam
Development and validation of stability indicating chromatographic methods for simultaneous determination of citicoline and piracetam
AbstractCiticoline and piracetam were subjected separately to different stress conditions as recommended by the international conference on harmonization. In addition, new stabilit...

Back to Top