Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Optimization of magnetic resonance imaging high-order axial shim coils using boundary element method

View through CrossRef
In this paper, we present a novel nonlinear optimization algorithm for designing a shim coil system, especially a high-order axial shim coil, for a magnetic resonance imaging(MRI) system. In an MRI equipment, in order to eliminate higher-order harmonic components of the magnetic field within the volume of interest(VOI), passive shimming(PS) is adopted in traditional methods. However, such a method is suitable for the global shimming with low accuracy and poor target. Active shimming(AS) makes up for the shortcomings from PS with a set of shim coils which are designed to generate a specific magnetic fields to improve magnetic field homogeneity within the VOI. Because the complexity of wire pattern increases with the order of AS coil increasing, conventional optimization model cannot meet the design requirements for producing the complicated magnetic field. In this paper, we propose a nonlinear optimization method of designing the axial shim coils for an open-style bi-planar MRI system, based on boundary element method. The optimization model is built in light of influence extents of the various parameters on the coil characteristics for different shim coils. In such a new method, the field error between the magnetic field produced by designed shim coil and the desired target value is selected to be an optimal value subjected to some constraints including line spacing and coil radius, which makes it possible to realize the manufacture process. Meanwhile, the more design parameters, which involve not only the stream function values at each node, but also the compensation parameters and/or the number of grid nodes, are regarded as optimized variables to control the magnetic deviation and characteristics of designed coil. By using some designed shim coils for a 0.5 T open style bi-planar superconducting MRI, including Z1, Z2, Z3 and Z4, the efficiency of such a numerical design method is displayed. Especially for high-order shim coils, more optimized parameters are involved to control the magnetic deviation of the coils, thereby providing a more flexible and straightforward method of designing the axial shim coils.
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Title: Optimization of magnetic resonance imaging high-order axial shim coils using boundary element method
Description:
In this paper, we present a novel nonlinear optimization algorithm for designing a shim coil system, especially a high-order axial shim coil, for a magnetic resonance imaging(MRI) system.
In an MRI equipment, in order to eliminate higher-order harmonic components of the magnetic field within the volume of interest(VOI), passive shimming(PS) is adopted in traditional methods.
However, such a method is suitable for the global shimming with low accuracy and poor target.
Active shimming(AS) makes up for the shortcomings from PS with a set of shim coils which are designed to generate a specific magnetic fields to improve magnetic field homogeneity within the VOI.
Because the complexity of wire pattern increases with the order of AS coil increasing, conventional optimization model cannot meet the design requirements for producing the complicated magnetic field.
In this paper, we propose a nonlinear optimization method of designing the axial shim coils for an open-style bi-planar MRI system, based on boundary element method.
The optimization model is built in light of influence extents of the various parameters on the coil characteristics for different shim coils.
In such a new method, the field error between the magnetic field produced by designed shim coil and the desired target value is selected to be an optimal value subjected to some constraints including line spacing and coil radius, which makes it possible to realize the manufacture process.
Meanwhile, the more design parameters, which involve not only the stream function values at each node, but also the compensation parameters and/or the number of grid nodes, are regarded as optimized variables to control the magnetic deviation and characteristics of designed coil.
By using some designed shim coils for a 0.
5 T open style bi-planar superconducting MRI, including Z1, Z2, Z3 and Z4, the efficiency of such a numerical design method is displayed.
Especially for high-order shim coils, more optimized parameters are involved to control the magnetic deviation of the coils, thereby providing a more flexible and straightforward method of designing the axial shim coils.

Related Results

Characterization of real B0 shim fields generated by higher order B0 shim systems of whole body human 3T and 7T MRI systems
Characterization of real B0 shim fields generated by higher order B0 shim systems of whole body human 3T and 7T MRI systems
Purpose Ensuring optimal homogeneity of the static magnetic field (B0) is critically important for significantly enhancing the image quality, spectral resolution, an...
Experimental and numerical study of blood flow in cerebral aneurysms treated with endovascular coils
Experimental and numerical study of blood flow in cerebral aneurysms treated with endovascular coils
Etude numérique et expérimentale du flux sanguin dans des anévrismes cérébraux après déploiement de coils Une des complications fréquentes des anévrismes cérébraux ...
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. ...
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Recent Progress in the Preparation Technologies for Micro Metal Coils
Recent Progress in the Preparation Technologies for Micro Metal Coils
The recent development of micro-fabrication technologies has provided new methods for researchers to design and fabricate micro metal coils, which will allow the coils to be smalle...
Axial dipole moments of solar active regions in cycles 21-24
Axial dipole moments of solar active regions in cycles 21-24
<p>The axial dipole moments of emerging active regions control the evolution of the axial dipole moment of the whole photospheric magnetic field and the strength of p...
Evaluation of Axial and Lateral Modal Superposition for General 3D Drilling Riser Analysis
Evaluation of Axial and Lateral Modal Superposition for General 3D Drilling Riser Analysis
Abstract A 3D partially non-linear transient filly-coupled riser analysis method is evaluated which uses modal superposition of independently extracted lateral an...

Back to Top