Javascript must be enabled to continue!
Testing XLE For Cost Savings in the DJ Basin: A Fiber Optic Case Study
View through CrossRef
Abstract
Historically, Great Western Petroleum has been an operator focused on efficiency without much focus on altering completion designs. Based on the successes of Extreme Limited Entry (XLE) in other basins, a science project was constructed to test different XLE in the first zipper group of a two-zipper group pad. The goal was to find a design that would yield the same production, but with less cost. Increasing stage length provides a significant cost saving and with XLE, production should be maintained. Based on the results from zipper one, the best design could then be implemented on the same pad in the second zipper group. This allows for a direct comparison of hydraulic fracturing designs, minimizing geologic impact.
This study was comprised of a number of different datasets with the primary focus being on Distributed Acoustic Sensing (DAS) using wellbore fiber optic cable. DAS is a rapidly evolving technology with numerous advances in both function and cost over the last few years, especially in fiber optic cable deployment. An opportunity was seen to not just gather data, but to test the data quality of the latest deployment methods, specifically a pump-down dissolvable, single-use fiber optic cable. This is a cost effective and minimal footprint option for data collection. This project included three acquisition methods for the DAS: 1) a permanent fiber optic line cemented on the outside of the casing, 2) a wireline retrievable fiber optic line, and 3) a pump-down dissolvable single-use fiber, all deployed in three unique wellbores. The permanent fiber optic well was used to compare the uniformity index of different completion designs. The designs were altered based on the results from the previous stage until an optimal design was reached. This DAS acquisition also provided offset strain and microseismic in the first and second zipper groups. The wireline retrievable fiber optic cable and single-use fiber optic cable deployments provided offset strain and microseismic for the wells in the first zipper group. High level observations resulting from this project include:
The data quality associated with the dissolvable single-use fiber looked comparable in data quality to the other fiber optic deployment methods. The Uniformity Index was high for most designs, even with stages as long as 450 ft and cluster spacing as tight as 7 ft. 350’ stages with 14 clusters at 1 spf was chosen for the second zipper group wells This provided significant cost savings, along with high stage uniformity Results from the offset strain and microseismic analysis from tighter and more clusters per stage showed less interference than what was seen with our legacy design stages RTA shows that compared to a pad with similar well spacing, the production is better with the new hydraulic fracture design
Having a case study with various fiber optic deployments is rare. At the time of this deployment, this was the first pump down dissolvable single-use fiber optic line in North America. This paper will show the efficacy of this fiber optic deployment compared to its peers. It also will look at conventional and XLE designs and the well-to-well interference differences. Finally, being able to compare production results to an offset pad with the same well spacing provides a unique opportunity to validate the effect of a new hydraulic fracture design.
Title: Testing XLE For Cost Savings in the DJ Basin: A Fiber Optic Case Study
Description:
Abstract
Historically, Great Western Petroleum has been an operator focused on efficiency without much focus on altering completion designs.
Based on the successes of Extreme Limited Entry (XLE) in other basins, a science project was constructed to test different XLE in the first zipper group of a two-zipper group pad.
The goal was to find a design that would yield the same production, but with less cost.
Increasing stage length provides a significant cost saving and with XLE, production should be maintained.
Based on the results from zipper one, the best design could then be implemented on the same pad in the second zipper group.
This allows for a direct comparison of hydraulic fracturing designs, minimizing geologic impact.
This study was comprised of a number of different datasets with the primary focus being on Distributed Acoustic Sensing (DAS) using wellbore fiber optic cable.
DAS is a rapidly evolving technology with numerous advances in both function and cost over the last few years, especially in fiber optic cable deployment.
An opportunity was seen to not just gather data, but to test the data quality of the latest deployment methods, specifically a pump-down dissolvable, single-use fiber optic cable.
This is a cost effective and minimal footprint option for data collection.
This project included three acquisition methods for the DAS: 1) a permanent fiber optic line cemented on the outside of the casing, 2) a wireline retrievable fiber optic line, and 3) a pump-down dissolvable single-use fiber, all deployed in three unique wellbores.
The permanent fiber optic well was used to compare the uniformity index of different completion designs.
The designs were altered based on the results from the previous stage until an optimal design was reached.
This DAS acquisition also provided offset strain and microseismic in the first and second zipper groups.
The wireline retrievable fiber optic cable and single-use fiber optic cable deployments provided offset strain and microseismic for the wells in the first zipper group.
High level observations resulting from this project include:
The data quality associated with the dissolvable single-use fiber looked comparable in data quality to the other fiber optic deployment methods.
The Uniformity Index was high for most designs, even with stages as long as 450 ft and cluster spacing as tight as 7 ft.
350’ stages with 14 clusters at 1 spf was chosen for the second zipper group wells This provided significant cost savings, along with high stage uniformity Results from the offset strain and microseismic analysis from tighter and more clusters per stage showed less interference than what was seen with our legacy design stages RTA shows that compared to a pad with similar well spacing, the production is better with the new hydraulic fracture design
Having a case study with various fiber optic deployments is rare.
At the time of this deployment, this was the first pump down dissolvable single-use fiber optic line in North America.
This paper will show the efficacy of this fiber optic deployment compared to its peers.
It also will look at conventional and XLE designs and the well-to-well interference differences.
Finally, being able to compare production results to an offset pad with the same well spacing provides a unique opportunity to validate the effect of a new hydraulic fracture design.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Introduction: Idiopathic optic neuritis is an optic neuropathy with characteristics of optic nerve dysfunction that can be caused by various disorders of the optic nerve, including...
Clinical features of COVID-19-related optic neuritis: a retrospective study
Clinical features of COVID-19-related optic neuritis: a retrospective study
ObjectiveThis retrospective study aimed to investigate the clinical features of optic neuritis associated with COVID-19 (COVID-19 ON), comparing them with neuromyelitis optica-asso...
Optic Nerve Disorders
Optic Nerve Disorders
Abstract
Just as neuro-ophthalmology links ophthalmology with other medical specialties, so too the optic nerve links the eye with the central nervous system. Thus, ...
Application of Optical Sensors in Deepwater Environments
Application of Optical Sensors in Deepwater Environments
Abstract
Fiber optic sensors are currently being deployed in novel completions throughout the world. The first completions being targeted are wells where specific...
Hereditary Optic Neuropathies
Hereditary Optic Neuropathies
Abstract
Hereditary optic neuropathies are a group of disorders characterized by optic nerve damage in which the underlying cause is heritable. Optic atrophy is a cl...
Enhancing Landslide Early Warning: Advances in Fiber Optic Sensor Sensitivity
Enhancing Landslide Early Warning: Advances in Fiber Optic Sensor Sensitivity
Fiber optic sensors offer a high-performance alternative because they provide a low-cost solution, resistance to electromagnetic interference, multiplexing capabilities, and high i...
The Genetic Mechanism of the Sequence Stratigraphy of the Rift Lacustrine Basin in Jiyang Depression, East China
The Genetic Mechanism of the Sequence Stratigraphy of the Rift Lacustrine Basin in Jiyang Depression, East China
Abstract
Through the studies of sequence stratigraphy of early Tertiary in the east part of Jiyang depression, the characteristics of sequence evolution in contin...

