Javascript must be enabled to continue!
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
View through CrossRef
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that cause global warming and greenhouse effect. Flat plate collector was used because it’s easy, ninexpensive and efficient. Many test runs (more than 50) were carried out on the system from May to October, 2013; the main results were taken between the period of July 15, 2013 to August 15, 2013 to find the maximum C.O.P, cooling, temperature and pressure of the system. The system demonstrates a maximum generator temperature of 93.5 oC, on July 18, 2013 at 2:30 pm, and the average mean generator temperature Tgavr was 74.7 °C, for this period. The maximum pressure Pg obtained was 2.25 bar on July 19, 2013 at 2:00 pm. The current system shows cooling capacity of 0.15 ton with coefficient of performance of 0.48, and minimum evaporator temperature obtained was 14.2oC. A comparison of the present with previous works, showed that most of the previous work used ammonia as the main refrigerant, and even that used methanol it was as aqua methanol, or to be part of pair refrigerant, while the present work use the methanol as the main and the only refrigerant in the system. The results and the factors that provided by the current work, give a good understanding for using the methanol as a refrigerant with the solar absorption system. And the system can work in continuous operation cycle. This work gave fundamental understanding for designing solar refrigeration system, by using the results of present study to design air-conditioning unit, with one ton capacity, using the solar energy, and the methanol as a refrigerant.
Journal of Engineering
Title: Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Description:
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that cause global warming and greenhouse effect.
Flat plate collector was used because it’s easy, ninexpensive and efficient.
Many test runs (more than 50) were carried out on the system from May to October, 2013; the main results were taken between the period of July 15, 2013 to August 15, 2013 to find the maximum C.
O.
P, cooling, temperature and pressure of the system.
The system demonstrates a maximum generator temperature of 93.
5 oC, on July 18, 2013 at 2:30 pm, and the average mean generator temperature Tgavr was 74.
7 °C, for this period.
The maximum pressure Pg obtained was 2.
25 bar on July 19, 2013 at 2:00 pm.
The current system shows cooling capacity of 0.
15 ton with coefficient of performance of 0.
48, and minimum evaporator temperature obtained was 14.
2oC.
A comparison of the present with previous works, showed that most of the previous work used ammonia as the main refrigerant, and even that used methanol it was as aqua methanol, or to be part of pair refrigerant, while the present work use the methanol as the main and the only refrigerant in the system.
The results and the factors that provided by the current work, give a good understanding for using the methanol as a refrigerant with the solar absorption system.
And the system can work in continuous operation cycle.
This work gave fundamental understanding for designing solar refrigeration system, by using the results of present study to design air-conditioning unit, with one ton capacity, using the solar energy, and the methanol as a refrigerant.
Related Results
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract
A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract
It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...
Analysis of Solar Powered Air Conditioning Systems for Residential Applications
Analysis of Solar Powered Air Conditioning Systems for Residential Applications
In this paper the absorption air conditioning system has been analyzed, and the solar energy has been used as a source for heat required to operating the absorption cycle. The infl...
Analysis on the Implementation of a Solar-Powered Automobile Air Conditioning System (SPAAS)
Analysis on the Implementation of a Solar-Powered Automobile Air Conditioning System (SPAAS)
This study presents the implementation of a Solar-Powered Automobile Air-Conditioning System (SPAAS), offering a sustainable alternative to conventional vehicle air conditioning. I...
Neural substrates underlying human delay and trace eyeblink conditioning
Neural substrates underlying human delay and trace eyeblink conditioning
Classical conditioning paradigms, such as trace conditioning, in which a silent period elapses between the offset of the conditioned stimulus (CS) and the delivery of the unconditi...
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
The article examines the load change schedule of the solar power plant in the Ukraine-Moldova energy union. The analysis of data averaged at minute and 15-minute intervals in the p...
Surface Roughness of Er, Cr: YSGG Laser Etched Enamel Compared to Acid Etching: An In Vitro Study
Surface Roughness of Er, Cr: YSGG Laser Etched Enamel Compared to Acid Etching: An In Vitro Study
Objectives:
Erbium-based lasers have been used in dentistry with different parameters for enamel conditioning with controversial results on the optimum parameter. This st...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract
All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...