Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

In vitro loading models for tendon mechanobiology

View through CrossRef
ABSTRACTTendons are the connective tissue responsible for transferring force from muscles to bones. A key factor in tendon development, maturation, repair, and degradation is its biomechanical environment. Understanding tendon mechanobiology is essential for the development of injury prevention strategies, rehabilitation protocols and potentially novel treatments in tendon injury and degeneration. Despite the simple overall loading on tendon tissue, cells within the tissue in vivo experience a much more complex mechanical environment including tension, compression and shear forces. This creates a substantial challenge in the establishment of in vitro loading models of the tendon. This article reviews multiple loading models used for the study of tendon mechanobiology and summarizes the main findings. Although impressive progress has been achieved in the functionality and mimicry of in vitro loading models, an ideal platform is yet to be developed. Multidisciplinary approaches and collaborations will be the key to unveiling the tendon mechanobiology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:566–575, 2018.
Title: In vitro loading models for tendon mechanobiology
Description:
ABSTRACTTendons are the connective tissue responsible for transferring force from muscles to bones.
A key factor in tendon development, maturation, repair, and degradation is its biomechanical environment.
Understanding tendon mechanobiology is essential for the development of injury prevention strategies, rehabilitation protocols and potentially novel treatments in tendon injury and degeneration.
Despite the simple overall loading on tendon tissue, cells within the tissue in vivo experience a much more complex mechanical environment including tension, compression and shear forces.
This creates a substantial challenge in the establishment of in vitro loading models of the tendon.
This article reviews multiple loading models used for the study of tendon mechanobiology and summarizes the main findings.
Although impressive progress has been achieved in the functionality and mimicry of in vitro loading models, an ideal platform is yet to be developed.
Multidisciplinary approaches and collaborations will be the key to unveiling the tendon mechanobiology.
© 2017 Orthopaedic Research Society.
Published by Wiley Periodicals, Inc.
J Orthop Res 36:566–575, 2018.

Related Results

Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
ABSTRAK Latar Belakang : Perkembangan tendon Palmaris Longus sudah lengkap saat dilahirkan. Tendon Palmaris Longus tidak akan berkembang lagi sesudah itu. tendon Palmaris Longus se...
Spontaneous Bilateral Patellar Tendon Rupture in Patient with Ehlers–Danlos Syndrome: A Case Report
Spontaneous Bilateral Patellar Tendon Rupture in Patient with Ehlers–Danlos Syndrome: A Case Report
Introduction: Bilateral spontaneous patellar tendon ruptures are rare, though it is hypothesized to be more common in patients with risk factors such as connective tissue disorders...
Biomimetic Breakthrough: Enhancing Tendon Repair with dAM- TDSCs
Biomimetic Breakthrough: Enhancing Tendon Repair with dAM- TDSCs
Abstract Background Adhesions and poor healing are major complications after Achilles tendon injury, and there is no effective solution to this problem. The purpose of this...
High-Performance Tendon For TLP Manufactured By Quench And Temper
High-Performance Tendon For TLP Manufactured By Quench And Temper
Abstract For the purpose of cost saving, three-piece tendon, which consists of a straight pipe with a couple of threaded forging connectors welded to both ends, i...
TGF-β3 Regulates Adhesion Formation Through the JNK/c-Jun Pathway During Flexor Tendon Healing
TGF-β3 Regulates Adhesion Formation Through the JNK/c-Jun Pathway During Flexor Tendon Healing
Abstract Background: The injured flexor tendon has poor healing ability, 15 which is easy to cause tendon adhesion. It can affect the recovery of tendon function, which is ...
In Vivo and In Vitro Tendon Engineering
In Vivo and In Vitro Tendon Engineering
Tendon is an important supportive tissue of human body responsible for normal physical activity. However, tendon damage and defect remain an important factor for causing disability...
Human Achilles tendon: Absence of renewal during adult life revealed by nuclear bomb 14C
Human Achilles tendon: Absence of renewal during adult life revealed by nuclear bomb 14C
Tendons connect muscle to bone and transmit enormous, repetitive forces during movement. The prevalence of tendon overuse‐injuries is high, and these conditions are often prolonged...

Back to Top