Javascript must be enabled to continue!
Complex discrete samples in electrocardiosignal processing tasks
View through CrossRef
A typical task of preprocessing an electrocardiosignal is to eliminate the isoline drift. The presence of the isoline drift changes the position of the ST segment relative to the zero line, which leads to a distortion of the informative parameters of the ST segment. Modern electrocardiographs are equipped with high-pass filters for isoline drift removal. In this case, along with the isoline drift, a part of the spectral components of the useful signal is removed from the electrocardiogram signal. Preservation of the components of the spectrum of the electrocardiogram signal is possible by interpolating discrete samples of the isoline drift signal taken on the PQ segment or the TP interval. In this case, the sampling rate of the isoline drift signal is determined by the heart rate. Consequently, when the frequency of the isoline drift signal changing increases, the accuracy of its recovery deteriorates, and when half of the heart rate is reached, recovery becomes impossible. Purpose – the working purpose is to find ways to eliminate the isoline drift even in the presence of components in its spectrum with frequencies reaching the heart rate, while preserving the informative spectral components of the electrocardiosignal. This purpose can be achieved by converting the samples of the isoline drift signal taken at the TP interval of the electrocardiosignal into a group of samples forming a complex discrete sample (CDS). In the spectrum of the CDS sequence, the specified spectral zones can be suppressed. It is sufficient to suppress the first spectral zone at the sampling rate equal to the average heart rate to isolate the isoline drift. In this case, the frequency of the isolated isoline drift signal can theoretically be increased to the sampling rate, which is up to the heart rate. Due to the heart rate variability, the isoline drift signal samples taken at the TP interval will have a varying repetition period (sampling period). To take this fact into account, the following tasks have been solved. The analysis of the spectral composition of the sequences of samples, from which complex discrete samples are formed, has been carried out with a changing sampling rate. Pulse-frequency modulation is used as a mathematical model of the sample sequence. It has been found that with a changing sampling rate, the side components remain non-suppressed in the suppressed spectral zone at the frequencies that differ from the sampling rate by the frequency of sampling rate change. The conditions for the equality of all spectral components in the suppressed spectral zone to zero have been determined. Mathematical expressions that describe these conditions and allow us to determine the amplitude-time parameters of the CDS necessary for the implementation of these conditions have been obtained. Mathematical simulation of the CDS spectra, which confirmed the workability of the proposed description of the CDS with a changing sampling period, has been carried out. The obtained mathematical expressions allow us to determine the structure and amplitude-time parameters of complex discrete samples that provide suppression of the specified spectral components with a changing sampling period, which provides an extension of the frequency range of the isolated isoline drift signal while preserving the informative components of the electrocardiosignal.
Publishing house "Radiotekhnika"
Title: Complex discrete samples in electrocardiosignal processing tasks
Description:
A typical task of preprocessing an electrocardiosignal is to eliminate the isoline drift.
The presence of the isoline drift changes the position of the ST segment relative to the zero line, which leads to a distortion of the informative parameters of the ST segment.
Modern electrocardiographs are equipped with high-pass filters for isoline drift removal.
In this case, along with the isoline drift, a part of the spectral components of the useful signal is removed from the electrocardiogram signal.
Preservation of the components of the spectrum of the electrocardiogram signal is possible by interpolating discrete samples of the isoline drift signal taken on the PQ segment or the TP interval.
In this case, the sampling rate of the isoline drift signal is determined by the heart rate.
Consequently, when the frequency of the isoline drift signal changing increases, the accuracy of its recovery deteriorates, and when half of the heart rate is reached, recovery becomes impossible.
Purpose – the working purpose is to find ways to eliminate the isoline drift even in the presence of components in its spectrum with frequencies reaching the heart rate, while preserving the informative spectral components of the electrocardiosignal.
This purpose can be achieved by converting the samples of the isoline drift signal taken at the TP interval of the electrocardiosignal into a group of samples forming a complex discrete sample (CDS).
In the spectrum of the CDS sequence, the specified spectral zones can be suppressed.
It is sufficient to suppress the first spectral zone at the sampling rate equal to the average heart rate to isolate the isoline drift.
In this case, the frequency of the isolated isoline drift signal can theoretically be increased to the sampling rate, which is up to the heart rate.
Due to the heart rate variability, the isoline drift signal samples taken at the TP interval will have a varying repetition period (sampling period).
To take this fact into account, the following tasks have been solved.
The analysis of the spectral composition of the sequences of samples, from which complex discrete samples are formed, has been carried out with a changing sampling rate.
Pulse-frequency modulation is used as a mathematical model of the sample sequence.
It has been found that with a changing sampling rate, the side components remain non-suppressed in the suppressed spectral zone at the frequencies that differ from the sampling rate by the frequency of sampling rate change.
The conditions for the equality of all spectral components in the suppressed spectral zone to zero have been determined.
Mathematical expressions that describe these conditions and allow us to determine the amplitude-time parameters of the CDS necessary for the implementation of these conditions have been obtained.
Mathematical simulation of the CDS spectra, which confirmed the workability of the proposed description of the CDS with a changing sampling period, has been carried out.
The obtained mathematical expressions allow us to determine the structure and amplitude-time parameters of complex discrete samples that provide suppression of the specified spectral components with a changing sampling period, which provides an extension of the frequency range of the isolated isoline drift signal while preserving the informative components of the electrocardiosignal.
Related Results
Methods for studying heart rate variability (review)
Methods for studying heart rate variability (review)
Currently, one of the most popular methods worldwide for studying and evaluating the work of the heart, the functional state of the body as a whole and the state of various departm...
Echinococcus granulosus in Environmental Samples: A Cross-Sectional Molecular Study
Echinococcus granulosus in Environmental Samples: A Cross-Sectional Molecular Study
Abstract
Introduction
Echinococcosis, caused by tapeworms of the Echinococcus genus, remains a significant zoonotic disease globally. The disease is particularly prevalent in areas...
Decoding task representations that support generalization in hierarchical task
Decoding task representations that support generalization in hierarchical task
AbstractTask knowledge can be encoded hierarchically such that complex tasks can be built by associating simpler tasks. This associative organization supports generalization to fac...
Children’s Discrete Proportional Reasoning Is Related to Inhibitory Control and Enhanced by Priming Continuous Representations
Children’s Discrete Proportional Reasoning Is Related to Inhibitory Control and Enhanced by Priming Continuous Representations
Children can successfully compare continuous proportions as early as age 4, yet struggle to compare discrete proportions least to age 10, especially when the discrete information i...
British Food Journal Volume 36 Issue 11 1934
British Food Journal Volume 36 Issue 11 1934
During the year the appointments of 32 Public Analysts were approved. The number of samples of food analysed by Public Analysts during the year 1933 was 138, 171, a slight increase...
579. Epidemiological Data Differences between Gel-purified vs. DNA-purified Oral Polio Vaccine in environmental samples
579. Epidemiological Data Differences between Gel-purified vs. DNA-purified Oral Polio Vaccine in environmental samples
Abstract
Background
As wild poliovirus is eradicated, preventing circulation of vaccine-derived poliovirus is top priority. Our ...
Physico-chemical Characterization and Estimation of Antimicrobial Activity of Modified Aspirin in the form of Nano-organometallic Compounds
Physico-chemical Characterization and Estimation of Antimicrobial Activity of Modified Aspirin in the form of Nano-organometallic Compounds
Aspirin is one of the most commonly used drugs. It is necessary to find and develop analgesic anti- inflammatory drugs that are safe against their adverse effects. From this standp...
Novel Techniques for Classifying Exotic Spheres in High Dimensions
Novel Techniques for Classifying Exotic Spheres in High Dimensions
Discrete calculus deals with developing the concepts and techniques of differential and integral calculus in a discrete setting, often using difference equations and discrete funct...

