Javascript must be enabled to continue!
Comparative evaluation of dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials: An in vitro study
View through CrossRef
Abstract
Aim:
The study aimed to evaluate and compare the dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials.
Settings and Design:
This study was an
in vitro
study.
Materials and Methods:
Two commercially available interocclusal recording materials were taken—polyvinyl siloxane and bis-acrylic. Two groups each of 40 specimens were made, and a stainless-steel master die was prepared according to American dental association specification no. 19. The die consisted of cylindrical ruled block with a diameter of 38 mm, height of 31 mm, mold, and a metal riser. Materials were homogenously mixed and loaded in the prepared die to obtain the specimen in the form of a disc measuring 3 mm in thickness and 30 mm in diameter with three parallel lines on the surface designated as X, Y, and Z, and two vertical lines marked as CD, C’D’. The specimens were submerged in a 36 ± 1°C water bath for 3 min. Distance between lines was measured with the contour measuring device Contracer at 1, 24, 48, and 72 h time intervals, and the values were statistically analyzed.
Statistical Analysis Used:
The samples were statistically analyzed using the statistical software (STATA 15.0),
t
test was used to access the significant differences, and the results were presented. The level of statistical significance was set at less than 0.05.
Results:
Both the materials showed maximum accuracy and dimensional stability in the initial stages but decreased as the time factor increased. The results showed a less significant percentage of dimensional change for bis-acrylic-based material, whereas polyvinyl siloxane exhibited significant dimensional changes up to 48 h.
Conclusion:
Dimensional changes were influenced by both material and time factors, and the difference exhibited by the materials were statistically significant at 1, 24, and 48 h.
Ovid Technologies (Wolters Kluwer Health)
Title: Comparative evaluation of dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials: An in vitro study
Description:
Abstract
Aim:
The study aimed to evaluate and compare the dimensional stability, accuracy, and reproducibility of two commercially available interocclusal recording materials.
Settings and Design:
This study was an
in vitro
study.
Materials and Methods:
Two commercially available interocclusal recording materials were taken—polyvinyl siloxane and bis-acrylic.
Two groups each of 40 specimens were made, and a stainless-steel master die was prepared according to American dental association specification no.
19.
The die consisted of cylindrical ruled block with a diameter of 38 mm, height of 31 mm, mold, and a metal riser.
Materials were homogenously mixed and loaded in the prepared die to obtain the specimen in the form of a disc measuring 3 mm in thickness and 30 mm in diameter with three parallel lines on the surface designated as X, Y, and Z, and two vertical lines marked as CD, C’D’.
The specimens were submerged in a 36 ± 1°C water bath for 3 min.
Distance between lines was measured with the contour measuring device Contracer at 1, 24, 48, and 72 h time intervals, and the values were statistically analyzed.
Statistical Analysis Used:
The samples were statistically analyzed using the statistical software (STATA 15.
0),
t
test was used to access the significant differences, and the results were presented.
The level of statistical significance was set at less than 0.
05.
Results:
Both the materials showed maximum accuracy and dimensional stability in the initial stages but decreased as the time factor increased.
The results showed a less significant percentage of dimensional change for bis-acrylic-based material, whereas polyvinyl siloxane exhibited significant dimensional changes up to 48 h.
Conclusion:
Dimensional changes were influenced by both material and time factors, and the difference exhibited by the materials were statistically significant at 1, 24, and 48 h.
Related Results
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Understanding reproducibility of bioinformatics workflows
Understanding reproducibility of bioinformatics workflows
Reproducibility is an essential factor in establishing the reliability of results reported in the scientific literature and ultimately in the knowledge that is generated. This know...
THREE-DIMENSIONAL HOLOGRAPHIC OPTICAL ELEMENTS BASED ON NEW MICROSYSTEMS
THREE-DIMENSIONAL HOLOGRAPHIC OPTICAL ELEMENTS BASED ON NEW MICROSYSTEMS
The origination and improvement of holographic methods, as well as technical equipment for their implementation [1–3] revived interest in light diffraction in three-dimensional per...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Comparative Evaluation Of Clinical And Radiographic Horizontal Condylar Guidance Angle Values By Using Two Different Interocclusal Recording Materials In Dentulous Patients
Introduction: The success of prosthodontic procedures can be accurately determined by the exact replication of the patient’s condylar path using a semi-adjustable articulator. It a...
Improving Reproducibility in AI Research: Four Mechanisms Adopted by JAIR
Improving Reproducibility in AI Research: Four Mechanisms Adopted by JAIR
Background: Lately, the reproducibility of scientific results has become an increasing worry in the scientific community. Several studies show that artificial intelligence research...
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Exploring Strategies for Optimizing Mobilenetv2 Performance in Classification Tasks Through Transfer Learning and Hyperparameter Tuning with A Local Dataset from Kigezi, Uganda.
Abstract
Background
Deep learning has proved to very vital in numerous applications in recent years. However, the development of a model may require access to datasets. Trainin...
Effect of recording window and stimulation variables on the statistical technique of motor unit number estimation
Effect of recording window and stimulation variables on the statistical technique of motor unit number estimation
AbstractA variety of methods are used for the selection of recording window sizes and stimulation current levels for statistical motor unit number estimation (MUNE). This study com...

