Abstract Static magnetic fields always exist the environment around us; besides being useful there are also negative impacts on humans, therefore it is necessary to have a tool to measure static magnetic fields. The purpose of this research is to produce a static magnetic field meter that can measure weak magnetic field. In this research, the design and realization of a static magnetic field meter using rotating search coil method is carried out, including: search coil, instrumentation and calibration amplifier, and display. Based on the results of measurements and tests that have been carried out, a static magnetic field meter with a coil area A = m2 and the number of turns N = 14 at a certain angular frequency (ω), can detect and measure a fairly small static magnetic field density (B) from various sources, for stable conditions: in the laboratory without any source of magnetic field can detect B = 2.127 to 2.375 mT, and with magnetic source (circular can detect B = 7.422 to 8.194 mT, neodymium can detect B = 11.03 to 11.84 mT, and smartphone X can detect B = 10.37 to 11.78 mT). Overall the device can work to detect and measure weak static magnetic fields with good measurement stability as seen from the relationship curve between supply voltage and the DC motor rotation which is linear, and measurement sensitivity up to B = 2.127 mT.
Universitas Muhammadiyah Surakarta
Title: Static Magnetic Field Meter Using Rotating Search Coil Method
Description:
Abstract Static magnetic fields always exist the environment around us; besides being useful there are also negative impacts on humans, therefore it is necessary to have a tool to measure static magnetic fields.
The purpose of this research is to produce a static magnetic field meter that can measure weak magnetic field.
In this research, the design and realization of a static magnetic field meter using rotating search coil method is carried out, including: search coil, instrumentation and calibration amplifier, and display.
Based on the results of measurements and tests that have been carried out, a static magnetic field meter with a coil area A = m2 and the number of turns N = 14 at a certain angular frequency (ω), can detect and measure a fairly small static magnetic field density (B) from various sources, for stable conditions: in the laboratory without any source of magnetic field can detect B = 2.
127 to 2.
375 mT, and with magnetic source (circular can detect B = 7.
422 to 8.
194 mT, neodymium can detect B = 11.
03 to 11.
84 mT, and smartphone X can detect B = 10.
37 to 11.
78 mT).
Overall the device can work to detect and measure weak static magnetic fields with good measurement stability as seen from the relationship curve between supply voltage and the DC motor rotation which is linear, and measurement sensitivity up to B = 2.
127 mT.
Related Results
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Domestic water meter optimal replacement period to minimize water revenue loss
Domestic water meter optimal replacement period to minimize water revenue loss
Water meter under-registration results in apparent losses and lost revenue for municipalities. Municipalities should scientifically determine the optimal replacement periods for th...
Current control and tuning in a closed HTS coil
Current control and tuning in a closed HTS coil
Up to today, a coil made of high temperature superconductor (HTS) usually needs a soldered joint to form a closed circuit. It is very difficult to have the joint fully superconduct...
Design 3D Printed Coils for WPT
Design 3D Printed Coils for WPT
Abstract
The geometric shapes of coils influence the performance of a 3D IPT system. In this paper, we proposed a 3D coil design method based on (3D) printing electr...
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Using coil antennae as transmitter and receiver to develop a geosteering tool, one has to increase the spacing between the transmitter and receiver to detect formation boundaries f...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
The design of magnetic resonance imaging (MRI) radiofrequency (RF) coils plays a critical role in determining image quality, with signal-to-noise ratio (SNR) and contrast-to-noise ...
A novel E-shaped coil for eddy current testing
A novel E-shaped coil for eddy current testing
Purpose
– Eddy current testing (ECT) is widely used in the non-destructive evaluation of materials in different industries. In this paper, ECT has been used to dete...