A New B-Scan System for Ophthalmic Diagnosis

View through CrossRef
A B-scan apparatus is presented comprising a mechanical scanning system, an electronic pulse shaping device, and a storage oscilloscope. The apparatus enables 90° arc-scan and sector scan, linear scan, linear-arc compound scan, and linear-sector compound scan. The various scan modes are motor driven. Several manipulators can be used to adjust the radius of the arc scan and sector scan, the distance of the centre of rotation to the eye, and the position of the mechanical system with respect to the eye, respectively. The whole system can be rotated around the centre of rotation of the arc scan and sector scan, so various cross-sections of the eye and the orbit can be obtained without further adjustments. A singular scan takes about 8 sec. The electronic system consists of a differentiator with negative capacitance coupling, and a level sensitive generator which delivers 0.2-μsec standard pulses. The patient is in supine position and acoustic coupling is obtained by means of a bassin filled with saline solution. The bassin is made of adhesive plastic drape that is fixed to the face and clamped around a metal ring.
Title: A New B-Scan System for Ophthalmic Diagnosis
Description:
A B-scan apparatus is presented comprising a mechanical scanning system, an electronic pulse shaping device, and a storage oscilloscope.
The apparatus enables 90° arc-scan and sector scan, linear scan, linear-arc compound scan, and linear-sector compound scan.
The various scan modes are motor driven.
Several manipulators can be used to adjust the radius of the arc scan and sector scan, the distance of the centre of rotation to the eye, and the position of the mechanical system with respect to the eye, respectively.
The whole system can be rotated around the centre of rotation of the arc scan and sector scan, so various cross-sections of the eye and the orbit can be obtained without further adjustments.
A singular scan takes about 8 sec.
The electronic system consists of a differentiator with negative capacitance coupling, and a level sensitive generator which delivers 0.
2-μsec standard pulses.
The patient is in supine position and acoustic coupling is obtained by means of a bassin filled with saline solution.
The bassin is made of adhesive plastic drape that is fixed to the face and clamped around a metal ring.

Related Results

EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Treatment Trends in Dry Eye Disease and Factors Associated with Ophthalmic Follow-up Discontinuation in Japan
Treatment Trends in Dry Eye Disease and Factors Associated with Ophthalmic Follow-up Discontinuation in Japan
Despite the importance of dry eye disease (DED) treatment, the rate of DED treatment discontinuation, especially discontinuation of ophthalmic follow-up, remains unknown. This stud...
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract Introduction The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Performance of ChatGPT in Ophthalmic Registration and Clinical Diagnosis: Cross-Sectional Study (Preprint)
Performance of ChatGPT in Ophthalmic Registration and Clinical Diagnosis: Cross-Sectional Study (Preprint)
BACKGROUND Artificial intelligence (AI) chatbots such as ChatGPT are expected to impact vision health care significantly. Their potential to optimize the co...
Assessment of Patients’ Knowledge, Perception and Safety Regarding MRI Scan
Assessment of Patients’ Knowledge, Perception and Safety Regarding MRI Scan
Correction: The page numbers on this article were changed from 4-20 to 3-19 on 31/08/2020. Introduction: We presume that the knowledge of patients about Magnetic Resonance imaging...
DECODING OF NON-TRAUMATIC ABDOMINAL PAIN: MULTIDETECTOR COMPUTED TOMOGRAPHY SCAN VERSUS ULTRASOUND: A RETROSPECTIVE CROSS-SECTIONAL STUDY
DECODING OF NON-TRAUMATIC ABDOMINAL PAIN: MULTIDETECTOR COMPUTED TOMOGRAPHY SCAN VERSUS ULTRASOUND: A RETROSPECTIVE CROSS-SECTIONAL STUDY
Objectives: Abdominal pain is one of the common presentations in outpatient and causality of hospitals. Ultrasound (USG) and computed tomography (CT) scans are commonly used to ass...
The experience with the application of Azidrop in the ophthalmological practice
The experience with the application of Azidrop in the ophthalmological practice
Introduction. The infectious inflammatory diseases of the eyes are characterized by the high prevalence and the potential risk of impairment of visual acuity. Background. It is wid...

Back to Top