Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dual versus conventional cardiac resynchronization: A pilot study

View through CrossRef
Background: Systolic heart failure treatment now includes cardiac resynchronization therapy (CRT) as a necessary element. CRT has been shown to have advantageous impacts on mortality, hospitalization rates, and quality of life. Approximately 30% of patients fail to respond to traditional CRT implantation. Aims and Objectives: This study aimed to compare the outcome of dual resynchronization by placing the right ventricular pacing lead at His bundle or left bundle branch area against conventional CRT. Materials and Methods: This longitudinal follow-up study of a total of 35 patients undergoing CRT device placement for assessment of safety, efficacy, and feasibility of the procedure and post-procedural complications and correlation with parameters obtained from electrocardiogram and echocardiography parameters in a tertiary care set up in India. Results: Among this matched population (mean age 64 years) there was a higher responder rate with the newer technique of dual resynchronization compared to conventional CRT (83% vs. 70%). Conclusion: Dual resynchronization therapy is feasible and safe and provides better electrical resynchronization compared to conventional CRT and could be a better alternative, especially when suboptimal electrical resynchronization is obtained.
Title: Dual versus conventional cardiac resynchronization: A pilot study
Description:
Background: Systolic heart failure treatment now includes cardiac resynchronization therapy (CRT) as a necessary element.
CRT has been shown to have advantageous impacts on mortality, hospitalization rates, and quality of life.
Approximately 30% of patients fail to respond to traditional CRT implantation.
Aims and Objectives: This study aimed to compare the outcome of dual resynchronization by placing the right ventricular pacing lead at His bundle or left bundle branch area against conventional CRT.
Materials and Methods: This longitudinal follow-up study of a total of 35 patients undergoing CRT device placement for assessment of safety, efficacy, and feasibility of the procedure and post-procedural complications and correlation with parameters obtained from electrocardiogram and echocardiography parameters in a tertiary care set up in India.
Results: Among this matched population (mean age 64 years) there was a higher responder rate with the newer technique of dual resynchronization compared to conventional CRT (83% vs.
70%).
Conclusion: Dual resynchronization therapy is feasible and safe and provides better electrical resynchronization compared to conventional CRT and could be a better alternative, especially when suboptimal electrical resynchronization is obtained.

Related Results

Predictive value of left atrial remodeling for response to cardiac resynchronization therapy
Predictive value of left atrial remodeling for response to cardiac resynchronization therapy
Aim: Response to cardiac resynchronization therapy varies significantly among patients, with one third of them failing to demonstrate left ventricular reverse ...
Dual versus conventional cardiac resynchronization: A pilot study
Dual versus conventional cardiac resynchronization: A pilot study
Background: Systolic heart failure treatment now includes cardiac resynchronization therapy (CRT) as a necessary element. CRT has been shown to have advantageous impacts on mortali...
Mediator kinase submodule-dependent regulation of cardiac transcription
Mediator kinase submodule-dependent regulation of cardiac transcription
<p>Pathological cardiac remodeling results from myocardial stresses including pressure and volume overload, neurohumoral activation, myocardial infarction, and hypothyroidism...
IOR Pilot Evaluation in a Brown-Field Fractured Reservoir Using Data Analytics of Reservoir Simulation Results
IOR Pilot Evaluation in a Brown-Field Fractured Reservoir Using Data Analytics of Reservoir Simulation Results
Abstract A well-designed pilot is instrumental in reducing uncertainty for the full-field implementation of improved oil recovery (IOR) operations. Traditional model...
Fuzzy logic‐based detection scheme for pilot fatigue
Fuzzy logic‐based detection scheme for pilot fatigue
PurposeThe paper aims to present the development of a detection scheme for pilot fatigue using fuzzy logic. Evaluation parameters based on the dynamic response of the pilot/aircraf...
International Breast Cancer Study Group (IBCSG)
International Breast Cancer Study Group (IBCSG)
This section provides current contact details and a summary of recent or ongoing clinical trials being coordinated by International Breast Cancer Study Group (IBCSG). Clinical tria...

Back to Top