Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of two commercial ELISA kits for detection of rubella specific IgM and IgG antibodies

View through CrossRef
Abstract Enzyme linked immunosorbent assay (ELISA) plays an important role in laboratory confirmation of congenital rubella syndrome (CRS), postnatal rubella and seroprevalence studies in different populations. Variation of results are documented for samples tested by different commercial kits. The Enzygnost rubella ELISA, widely used in the WHO network, is expensive and not readily available. In the present study, performance of the Euroimmun ELISA was compared to the Enzygnost ELISA for detection of rubella specific IgM and IgG antibodies. Two hundred and eighty five serum samples collected from suspected CRS patients identified through a recently initiated surveillance for CRS at six sentinel hospitals and 435 serum samples from a serosurvey of pregnant women from these sites, were available for testing of rubella specific IgM and IgG antibodies respectively. Qualitative agreement (concordance percentage and Cohen’s Kappa coefficient -κ) was evaluated for both IgM and IgG assays. Bland – Altman plots were used to assess the difference in quantitative agreement for IgG titers. Good qualitative agreement between the two ELISA kits was observed for detection of both anti rubella IgM (94.7% agreement and k of 0.86) and IgG (96.3% agreement and k of 0.84). Sensitivity and specificity of Euroimmun assays compared to Enzygnost was 100% and 93.1% for IgM and 95.9% and 100% for IgG respectively. Bland – Altman analysis for paired quantitative results of rubella specific IgG yielded a mean difference of 0.781 IU/ml with majority of values (97.1%) within ± 2 SD of the mean difference. Euroimmun ELISA provided on an average, higher titers as compared to Enzygnost. Our study findings suggest that Euroimmun ELISA may be considered for detection of rubella specific IgM in suspected CRS cases and rubella specific IgG in surveillance studies.
Title: Comparison of two commercial ELISA kits for detection of rubella specific IgM and IgG antibodies
Description:
Abstract Enzyme linked immunosorbent assay (ELISA) plays an important role in laboratory confirmation of congenital rubella syndrome (CRS), postnatal rubella and seroprevalence studies in different populations.
Variation of results are documented for samples tested by different commercial kits.
The Enzygnost rubella ELISA, widely used in the WHO network, is expensive and not readily available.
In the present study, performance of the Euroimmun ELISA was compared to the Enzygnost ELISA for detection of rubella specific IgM and IgG antibodies.
Two hundred and eighty five serum samples collected from suspected CRS patients identified through a recently initiated surveillance for CRS at six sentinel hospitals and 435 serum samples from a serosurvey of pregnant women from these sites, were available for testing of rubella specific IgM and IgG antibodies respectively.
Qualitative agreement (concordance percentage and Cohen’s Kappa coefficient -κ) was evaluated for both IgM and IgG assays.
Bland – Altman plots were used to assess the difference in quantitative agreement for IgG titers.
Good qualitative agreement between the two ELISA kits was observed for detection of both anti rubella IgM (94.
7% agreement and k of 0.
86) and IgG (96.
3% agreement and k of 0.
84).
Sensitivity and specificity of Euroimmun assays compared to Enzygnost was 100% and 93.
1% for IgM and 95.
9% and 100% for IgG respectively.
Bland – Altman analysis for paired quantitative results of rubella specific IgG yielded a mean difference of 0.
781 IU/ml with majority of values (97.
1%) within ± 2 SD of the mean difference.
Euroimmun ELISA provided on an average, higher titers as compared to Enzygnost.
Our study findings suggest that Euroimmun ELISA may be considered for detection of rubella specific IgM in suspected CRS cases and rubella specific IgG in surveillance studies.

Related Results

One-point evaluation of children exposed to rubella infection In Utero in Maiduguri, North-Eastern Nigeria: A follow-up Study
One-point evaluation of children exposed to rubella infection In Utero in Maiduguri, North-Eastern Nigeria: A follow-up Study
Background: Rubella is a disease caused by a virus, rubella virus. Major obstetrics concerns are profound effects of the virus on developing fetuses, which may result in multiple c...
Epidemiology of rubella infection in Cameroon: a 7-year experience of measles and rubella case-based surveillance, 2008–2014
Epidemiology of rubella infection in Cameroon: a 7-year experience of measles and rubella case-based surveillance, 2008–2014
ObjectiveThe aim of this study was to estimate the proportion of rubella disease in a measles case-based surveillance in Cameroon prior to rubella vaccine introduction into the nat...
Patterns of antiphospholipid antibody positivity in a real-world laboratory over two decades
Patterns of antiphospholipid antibody positivity in a real-world laboratory over two decades
Abstract Background Antiphospholipid syndrome (APS) is diagnosed when vascular thrombosis or pregnancy morbidity occurs ...
Performance evaluation of in-house developed Covid-19 IgG/IgM antibody rapid diagnostic kit
Performance evaluation of in-house developed Covid-19 IgG/IgM antibody rapid diagnostic kit
Abstract In the interest of preventing the Coronavirus Disease 2019 (COVID-19) pandemic from spreading, it is crucial to promptly identify and confine afflicted patients. S...
Seropositive Rubella and Toxoplasmosis Among Females Attending Saudi Hospital
Seropositive Rubella and Toxoplasmosis Among Females Attending Saudi Hospital
Background: Toxoplasma gondii and rubella virus are significant health concerns among women. Therefore, it is crucial to determine the preva...
Comparative evaluation of AxSYM, VIDAS and VIDIA toxoplasmosis reagent performance in a high seroprevalence Latin American country
Comparative evaluation of AxSYM, VIDAS and VIDIA toxoplasmosis reagent performance in a high seroprevalence Latin American country
AIMS: The purpose of this study was to compare the performance of three automated immunoassays for the detection of IgM and IgG Toxoplasma gondii antibodies using sera of pregnant ...
Improved and customized dengue serodiagnostics through combined NS1/IgM testing and novel dual-cut-off IgG ELISA
Improved and customized dengue serodiagnostics through combined NS1/IgM testing and novel dual-cut-off IgG ELISA
Background Accurate diagnostics of dengue virus (DENV) infection are essential for patient management, outbreak control, and vaccine implementation. Serological...

Back to Top