Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PRELIMINARY STUDIES INVALIDATE AUTOMATED HAEMO-ANALYZER RESULTS OF AVIAN BLOOD

View through CrossRef
Experiments were performed with the aim of determining the complete blood cell count of broiler chickens reared on 24-h continuous lighting photoperiod regimens using an automated haemoanalyzer. Six Marshal broiler chickens, randomly selected from a flock of three hundred served as subjects. On the experimental day. 2 ml of blood was collected from the wing vein of each bird at 13:00 h into ethylenediaminetetra acetic acid bottle. The blood was analyzed immediately using automated electronic cell counter for haematocrit, haemoglobin, red blood count, mean cell volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, red cell distribution width, thrombocytes, mean thrombocyte volume, thrombocyte distribution width, thrombocyte large cell ratio, total and differential leucocyte counts with their percentages. The automated machine did not process 50 % of the samples for red cell distribution width. Also, 83.33 % of the samples for mean thrombocyte volume, thrombocyte distribution width and thrombocyte large cell ratio were not processed by the machine. It is concluded that results of broiler chicken blood analyzed using automated haemoanalyzer may be accepted, but should be interpreted with caution.
Nigerian Society for Animal Production (NSAP)
Title: PRELIMINARY STUDIES INVALIDATE AUTOMATED HAEMO-ANALYZER RESULTS OF AVIAN BLOOD
Description:
Experiments were performed with the aim of determining the complete blood cell count of broiler chickens reared on 24-h continuous lighting photoperiod regimens using an automated haemoanalyzer.
Six Marshal broiler chickens, randomly selected from a flock of three hundred served as subjects.
On the experimental day.
2 ml of blood was collected from the wing vein of each bird at 13:00 h into ethylenediaminetetra acetic acid bottle.
The blood was analyzed immediately using automated electronic cell counter for haematocrit, haemoglobin, red blood count, mean cell volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, red cell distribution width, thrombocytes, mean thrombocyte volume, thrombocyte distribution width, thrombocyte large cell ratio, total and differential leucocyte counts with their percentages.
The automated machine did not process 50 % of the samples for red cell distribution width.
Also, 83.
33 % of the samples for mean thrombocyte volume, thrombocyte distribution width and thrombocyte large cell ratio were not processed by the machine.
It is concluded that results of broiler chicken blood analyzed using automated haemoanalyzer may be accepted, but should be interpreted with caution.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract  Introduction Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
Avian Influenza Viruses
Avian Influenza Viruses
Abstract Avian influenza viruses comprise all recognised antigenic subtypes within the genus Influenza A ...
Comparative assessment of nucleated red blood cells using a fully automated hematology analyzer versus slide examination.
Comparative assessment of nucleated red blood cells using a fully automated hematology analyzer versus slide examination.
Objective: To determine the sensitivity and specificity of fully automated hematology analyzer for nucleated red blood cells (NRBCs) keeping microscopic slide examination as gold s...
The avian vitamin D receptors: primary structures and their origins.
The avian vitamin D receptors: primary structures and their origins.
cDNA clones encoding Japanese quail chorioallantoic membrane and chicken kidney 1,25-dihydroxyvitamin D3 receptors were isolated and the total 448-amino acid (aa) sequence was dedu...

Back to Top